{"title":"Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty.","authors":"Lihui Sun, Yu Han, Zheng Jing, Dongbo Li, Jianguo Liu, Dongsong Li","doi":"10.1177/10225536241251926","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM).</p><p><strong>Methods: </strong>Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis.</p><p><strong>Results: </strong>As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner (<i>p</i> < .001).</p><p><strong>Conclusion: </strong>When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.</p>","PeriodicalId":16608,"journal":{"name":"Journal of Orthopaedic Surgery","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orthopaedic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536241251926","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM).

Methods: Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis.

Results: As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner (p < .001).

Conclusion: When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
全膝关节置换术中胫骨截骨对聚乙烯衬垫应力影响的有限元分析。
目的:通过建立有限元模型(FEM),探讨胫骨截骨曲度结合胫骨后斜度(PTS)对全膝关节置换术(TKA)中聚乙烯衬垫应力的影响:建立胫骨截骨曲度为 0° 至 9° 的标准 TKA 的有限元模型,并将其分为 10 组。然后,每组分别建立 10 个 0° 至 9° PTS 的有限元模型。在 Abaqus 中计算每组聚乙烯衬垫的应力。最后,采用多元回归分析法对胫骨截骨角度与聚乙烯衬垫应力之间的相关性进行统计分析:结果:随着屈曲角度的增加,聚乙烯衬垫的最大应力区域逐渐向内侧移动。随着 PTS 的增加,聚乙烯衬垫内侧和外侧的表面接触力百分比逐渐趋于一致。当屈曲角度在 0° 至 3° 之间时,聚乙烯衬垫内侧隔间表面的最大应力随着 PTS 的增加而平稳上升。当屈曲角度在 4° 至 9° 之间时,随着 PTS 的增加,聚乙烯衬垫的最大应力先上升后下降,在 PTS 5° 处形成低谷,然后再次上升。与 PTS 相比,屈曲角度对聚乙烯衬垫最大应力的影响较大(p < .001):结论:当屈曲角度为 0° 至 3° 时,建议采用 PTS 0°,这将使 TKA 中聚乙烯衬垫的应力分布更加均衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
91
期刊介绍: Journal of Orthopaedic Surgery is an open access peer-reviewed journal publishing original reviews and research articles on all aspects of orthopaedic surgery. It is the official journal of the Asia Pacific Orthopaedic Association. The journal welcomes and will publish materials of a diverse nature, from basic science research to clinical trials and surgical techniques. The journal encourages contributions from all parts of the world, but special emphasis is given to research of particular relevance to the Asia Pacific region.
期刊最新文献
Prediction models for deep vein thrombosis after knee/hip arthroplasty: A systematic review and network meta-analysis. Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty. Time to full weight-bearing with the use of a calcium sulfate-calcium phosphate bone substitute as a bone void filler following extended curettage in the treatment of primary benign bone tumours. Prognostic nomogram in middle-aged and elderly patients with chordoma: A SEER-based study. Double-pulley, V-shaped fixation technique for arthroscopic repair of ideberg type IA glenoid fracture.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1