Hacer Oncu, Ebru Calik-Kutukcu, Naciye Vardar Yagli, Deniz Inal-Ince, Melda Saglam, Ferhat Unal, Sercan Aksoy
{"title":"Reliability and validity of the 6-minute pegboard and ring test for functional exercise capacity in patients with breast cancer.","authors":"Hacer Oncu, Ebru Calik-Kutukcu, Naciye Vardar Yagli, Deniz Inal-Ince, Melda Saglam, Ferhat Unal, Sercan Aksoy","doi":"10.1080/09593985.2024.2353260","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Chronic pain, sensory disturbances, and lymphedema are frequent after breast cancer, leading to arm dysfunction. There is a need for objective performance-based clinical exercise tests for the upper extremity in patients with breast cancer.</p><p><strong>Objective: </strong>The aim of this study was to evaluate the validity and reliability of the 6-minute pegboard and ring test (6PBRT) in breast cancer survivors.</p><p><strong>Methods: </strong>Forty-eight women with breast cancer (mean age = 55.40 ± 10.40 years) were included. All patients performed 6PBRT on the first day and one week later to investigate the test-retest reliability of the 6PBRT, and intraclass correlation coefficients (ICC) were calculated. The peak workload (W<sub>peak</sub>) and oxygen consumption level (VO<sub>2peak</sub>) during the arm ergometer test were used as outcomes for the criterion validity of the 6PBRT.</p><p><strong>Results: </strong>The 6PBRT showed good test - retest reliability with an ICC<sub>1,2</sub> value of 0.871 [95% confidence interval (CI) 0.769-0.928]. The first 6PBRT score was very strongly correlated with the second test score (<i>r</i> = 0.866, <i>p</i> < .001). The 6PBRT score was significantly correlated with VO<sub>2peak</sub> (<i>r</i> = 0.634, <i>p</i> < .001), and W<sub>peak</sub> (<i>r</i> = 0.546, <i>p</i> < .001). While the 6PBRT score had less effect on VO<sub>2peak</sub>, the determination of VO<sub>2peak</sub> in the model was very good (R<sup>2</sup> = 0.832).</p><p><strong>Conclusion: </strong>The 6PBRT has good test-retest reliability and is a valid test in individuals with breast cancer. These findings suggest that 6PBRT is a practical, useful, valid and reliable assessment tool for determining functional arm exercise capacity in patients with breast cancer.</p>","PeriodicalId":48699,"journal":{"name":"Physiotherapy Theory and Practice","volume":" ","pages":"643-655"},"PeriodicalIF":1.6000,"publicationDate":"2025-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiotherapy Theory and Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09593985.2024.2353260","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/13 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"REHABILITATION","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Chronic pain, sensory disturbances, and lymphedema are frequent after breast cancer, leading to arm dysfunction. There is a need for objective performance-based clinical exercise tests for the upper extremity in patients with breast cancer.
Objective: The aim of this study was to evaluate the validity and reliability of the 6-minute pegboard and ring test (6PBRT) in breast cancer survivors.
Methods: Forty-eight women with breast cancer (mean age = 55.40 ± 10.40 years) were included. All patients performed 6PBRT on the first day and one week later to investigate the test-retest reliability of the 6PBRT, and intraclass correlation coefficients (ICC) were calculated. The peak workload (Wpeak) and oxygen consumption level (VO2peak) during the arm ergometer test were used as outcomes for the criterion validity of the 6PBRT.
Results: The 6PBRT showed good test - retest reliability with an ICC1,2 value of 0.871 [95% confidence interval (CI) 0.769-0.928]. The first 6PBRT score was very strongly correlated with the second test score (r = 0.866, p < .001). The 6PBRT score was significantly correlated with VO2peak (r = 0.634, p < .001), and Wpeak (r = 0.546, p < .001). While the 6PBRT score had less effect on VO2peak, the determination of VO2peak in the model was very good (R2 = 0.832).
Conclusion: The 6PBRT has good test-retest reliability and is a valid test in individuals with breast cancer. These findings suggest that 6PBRT is a practical, useful, valid and reliable assessment tool for determining functional arm exercise capacity in patients with breast cancer.
期刊介绍:
The aim of Physiotherapy Theory and Practice is to provide an international, peer-reviewed forum for the publication, dissemination, and discussion of recent developments and current research in physiotherapy/physical therapy. The journal accepts original quantitative and qualitative research reports, theoretical papers, systematic literature reviews, clinical case reports, and technical clinical notes. Physiotherapy Theory and Practice; promotes post-basic education through reports, reviews, and updates on all aspects of physiotherapy and specialties relating to clinical physiotherapy.