Rajat Manchanda, Ramanuj Samanta, Manishi L Narayan, Mritunjai Kumar, Ashutosh Tiwari, Ajai Agarwal, Yogesh Bahurupi, Sweety Kumari, Niraj Kumar
{"title":"Connecting the Dots: Exploring the Relationship between Optical Coherence Tomography and <sup>99m</sup>Tc-TRODAT-1 SPECT Parameters in Parkinson's Disease.","authors":"Rajat Manchanda, Ramanuj Samanta, Manishi L Narayan, Mritunjai Kumar, Ashutosh Tiwari, Ajai Agarwal, Yogesh Bahurupi, Sweety Kumari, Niraj Kumar","doi":"10.4103/aian.aian_31_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>While optical coherence tomography (OCT) is explored as a potential biomarker in Parkinson's disease (PD), technetium-99m-labeled tropane derivative (<sup>99m</sup>Tc-TRODAT-1) single-photon emission computed tomography (SPECT) imaging has a proven role in diagnosing PD. Our objective was to compare the OCT parameters in PD patients and healthy controls (HCs) and correlate them with <sup>99m</sup>Tc-TRODAT-1 parameters in PD patients.</p><p><strong>Materials and methods: </strong>This cross-sectional study included 30 PD patients and 30 age- and gender-matched HCs. Demographic data, PD details including Movement Disorders Society Unified Parkinson's Disease Rating Scale-III (MDS-UPDRS-III) and Hoehn-Yahr (HY) staging, and OCT parameters including macular and peripapillary retinal nerve fiber layer (RNFL) thickness in bilateral eyes were recorded. PD patients underwent <sup>99m</sup>Tc-TRODAT-1 SPECT imaging. The terms \"ipsilateral\" and \"contralateral\" were used with reference to more severely affected body side in PD patients and compared with corresponding sides in HCs.</p><p><strong>Results: </strong>PD patients showed significant ipsilateral superior parafoveal quadrant (mean ± standard deviation [SD] = 311.10 ± 15.90 vs. 297.57 ± 26.55, <i>P</i> = 0.02) and contralateral average perifoveal (mean ± SD = 278.75 ± 18.97 vs. 269.08 ± 16.91, <i>P</i> = 0.04) thinning compared to HCs. Peripapillary RNFL parameters were comparable between PD patients and HCs. MDS-UPDRS-III score and HY stage were inversely correlated to both ipsilateral (Spearman rho = -0.52, <i>P</i> = 0.003; Spearman rho = -0.47, <i>P</i> = 0.008) and contralateral (Spearman rho = -0.53, <i>P</i> = 0.002; Spearman rho = -0.58, <i>P</i> < 0.001) macular volumes, respectively. PD duration was inversely correlated with ipsilateral temporal parafoveal thickness (ρ = -0.41, <i>P</i> = 0.02). No correlation was observed between OCT and <sup>99m</sup>Tc-TRODAT-1 SPECT parameters in PD patients.</p><p><strong>Conclusion: </strong>Compared to HCs, a significant thinning was observed in the ipsilateral superior parafoveal quadrant and the contralateral average perifoveal region in PD patients. Macular volume and ipsilateral temporal parafoveal thickness were inversely correlated with disease severity and duration, respectively. OCT and <sup>99m</sup>Tc-TRODAT-1 SPECT parameters failed to correlate in PD patients.</p>","PeriodicalId":8036,"journal":{"name":"Annals of Indian Academy of Neurology","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11093162/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Indian Academy of Neurology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/aian.aian_31_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and objective: While optical coherence tomography (OCT) is explored as a potential biomarker in Parkinson's disease (PD), technetium-99m-labeled tropane derivative (99mTc-TRODAT-1) single-photon emission computed tomography (SPECT) imaging has a proven role in diagnosing PD. Our objective was to compare the OCT parameters in PD patients and healthy controls (HCs) and correlate them with 99mTc-TRODAT-1 parameters in PD patients.
Materials and methods: This cross-sectional study included 30 PD patients and 30 age- and gender-matched HCs. Demographic data, PD details including Movement Disorders Society Unified Parkinson's Disease Rating Scale-III (MDS-UPDRS-III) and Hoehn-Yahr (HY) staging, and OCT parameters including macular and peripapillary retinal nerve fiber layer (RNFL) thickness in bilateral eyes were recorded. PD patients underwent 99mTc-TRODAT-1 SPECT imaging. The terms "ipsilateral" and "contralateral" were used with reference to more severely affected body side in PD patients and compared with corresponding sides in HCs.
Results: PD patients showed significant ipsilateral superior parafoveal quadrant (mean ± standard deviation [SD] = 311.10 ± 15.90 vs. 297.57 ± 26.55, P = 0.02) and contralateral average perifoveal (mean ± SD = 278.75 ± 18.97 vs. 269.08 ± 16.91, P = 0.04) thinning compared to HCs. Peripapillary RNFL parameters were comparable between PD patients and HCs. MDS-UPDRS-III score and HY stage were inversely correlated to both ipsilateral (Spearman rho = -0.52, P = 0.003; Spearman rho = -0.47, P = 0.008) and contralateral (Spearman rho = -0.53, P = 0.002; Spearman rho = -0.58, P < 0.001) macular volumes, respectively. PD duration was inversely correlated with ipsilateral temporal parafoveal thickness (ρ = -0.41, P = 0.02). No correlation was observed between OCT and 99mTc-TRODAT-1 SPECT parameters in PD patients.
Conclusion: Compared to HCs, a significant thinning was observed in the ipsilateral superior parafoveal quadrant and the contralateral average perifoveal region in PD patients. Macular volume and ipsilateral temporal parafoveal thickness were inversely correlated with disease severity and duration, respectively. OCT and 99mTc-TRODAT-1 SPECT parameters failed to correlate in PD patients.
期刊介绍:
The journal has a clinical foundation and has been utilized most by clinical neurologists for improving the practice of neurology. While the focus is on neurology in India, the journal publishes manuscripts of high value from all parts of the world. Journal publishes reviews of various types, original articles, short communications, interesting images and case reports. The journal respects the scientific submission of its authors and believes in following an expeditious double-blind peer review process and endeavors to complete the review process within scheduled time frame. A significant effort from the author and the journal perhaps enables to strike an equilibrium to meet the professional expectations of the peers in the world of scientific publication. AIAN believes in safeguarding the privacy rights of human subjects. In order to comply with it, the journal instructs all authors when uploading the manuscript to also add the ethical clearance (human/animals)/ informed consent of subject in the manuscript. This applies to the study/case report that involves animal/human subjects/human specimens e.g. extracted tooth part/soft tissue for biopsy/in vitro analysis.