{"title":"Comparing the Outcomes of Titanium and Stainless Steel Flexible Nails in Repairing Pediatric Long Bone Fractures.","authors":"Mazen Zamzam, Novelpreet Bopari, Avianna Arapovic, Suzan Kamel-ElSayed, Ehab S Saleh","doi":"10.52965/001c.116898","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Traditionally, pediatric femoral fracture treatment favored conservative methods, relying on casting and the inherent bone remodeling ability in immature bones. Surgical intervention was deferred until age 6, as nonoperative approaches often resulted in complications. Titanium elastic nailing (TENS) emerged as an effective treatment for diaphyseal femoral fractures in ages 6 to 16. However, the choice between TENS and stainless steel elastic nailing (SSENS) remains debated due to inconsistent findings.</p><p><strong>Objective: </strong>This study aimed to evaluate the effectiveness of both nailing systems in pediatric long bone fractures.</p><p><strong>Methods: </strong>A retrospective chart review at William Beaumont Hospital Royal Oak included 83 patients aged 6 to 16 treated with TENS or SSENS between January 2011 and January 2021. Data collected encompassed nail related issues, time to fracture union, full weight bearing, and nail removal.</p><p><strong>Results: </strong>In the TENS group (n=29), the average age was 8.8±2.4 years, and the average BMI was 17.2±3.4. The SSENS group (n=54) had an average age of 9.3±2.7 and an average BMI of 19.7±8.4. Time to fracture union for TENS was 93.8±60.5 days, while SSENS was 82.2±40.0 days.</p><p><strong>Conclusion: </strong>This study found no statistically significant differences in nail-related complications, time to fracture union, full weight bearing, or nail removal between TENS and SSENS in pediatric long bone fractures. The choice between these systems should be based on individual circumstances. Limitations include a small sample size and the study's retrospective nature.</p>","PeriodicalId":19669,"journal":{"name":"Orthopedic Reviews","volume":"16 ","pages":"116898"},"PeriodicalIF":1.4000,"publicationDate":"2024-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11093719/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthopedic Reviews","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52965/001c.116898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Traditionally, pediatric femoral fracture treatment favored conservative methods, relying on casting and the inherent bone remodeling ability in immature bones. Surgical intervention was deferred until age 6, as nonoperative approaches often resulted in complications. Titanium elastic nailing (TENS) emerged as an effective treatment for diaphyseal femoral fractures in ages 6 to 16. However, the choice between TENS and stainless steel elastic nailing (SSENS) remains debated due to inconsistent findings.
Objective: This study aimed to evaluate the effectiveness of both nailing systems in pediatric long bone fractures.
Methods: A retrospective chart review at William Beaumont Hospital Royal Oak included 83 patients aged 6 to 16 treated with TENS or SSENS between January 2011 and January 2021. Data collected encompassed nail related issues, time to fracture union, full weight bearing, and nail removal.
Results: In the TENS group (n=29), the average age was 8.8±2.4 years, and the average BMI was 17.2±3.4. The SSENS group (n=54) had an average age of 9.3±2.7 and an average BMI of 19.7±8.4. Time to fracture union for TENS was 93.8±60.5 days, while SSENS was 82.2±40.0 days.
Conclusion: This study found no statistically significant differences in nail-related complications, time to fracture union, full weight bearing, or nail removal between TENS and SSENS in pediatric long bone fractures. The choice between these systems should be based on individual circumstances. Limitations include a small sample size and the study's retrospective nature.
期刊介绍:
Orthopedic Reviews is an Open Access, online-only, peer-reviewed journal that considers articles concerned with any aspect of orthopedics, as well as diagnosis and treatment, trauma, surgical procedures, arthroscopy, sports medicine, rehabilitation, pediatric and geriatric orthopedics. All bone-related molecular and cell biology, genetics, pathophysiology and epidemiology papers are also welcome. The journal publishes original articles, brief reports, reviews and case reports of general interest.