Platelet and INR Thresholds and Bleeding Risk in Ultrasound Guided Percutaneous Liver Biopsy: A Before-After Implementation of the 2019 Society of Interventional Radiology Guidelines Observational Quality Improvement Study.
Chloe DesRoche, Jeannie Callum, Aiden Scholey, Omar I Hajjaj, Jennifer Flemming, Ben Mussari, Emidio Tarulli, Amir Reza Nasirzadeh, Alexandre Menard
{"title":"Platelet and INR Thresholds and Bleeding Risk in Ultrasound Guided Percutaneous Liver Biopsy: A Before-After Implementation of the 2019 Society of Interventional Radiology Guidelines Observational Quality Improvement Study.","authors":"Chloe DesRoche, Jeannie Callum, Aiden Scholey, Omar I Hajjaj, Jennifer Flemming, Ben Mussari, Emidio Tarulli, Amir Reza Nasirzadeh, Alexandre Menard","doi":"10.1177/08465371241252059","DOIUrl":null,"url":null,"abstract":"<p><p><b>Purpose:</b> To evaluate if implementation of the 2019 Society of Interventional Radiology (SIR) guidelines for periprocedural management of bleeding risk in patients undergoing percutaneous ultrasound guided liver biopsy is associated with increased haemorrhagic adverse events, change in pre-procedural blood product utilization, and evaluation of guideline compliance rate at a single academic institution. <b>Methods:</b> Ultrasound guided percutaneous liver biopsies from (January 2019-January 2023) were retrospectively reviewed (n = 504), comparing biopsies performed using the 2012 SIR pre-procedural coagulation guidelines (n = 266) to those after implementation of the 2019 SIR pre-procedural guidelines (n = 238). Demographic, preprocedural transfusion, laboratory, and clinical data were reviewed. Chart review was conducted to evaluate the incidence of major bleeding adverse events defined as those resulting in transfusion, embolization, surgery, or death. <b>Results:</b> Implementation of the 2019 SIR periprocedural guidelines resulted in reduced guideline non-compliance related to the administration of blood products, from 5.3% to 1.7% (<i>P</i> = .01). The rate of pre-procedural transfusion remained the same pre and post guidelines at 0.8%. There was no statistically significant change in the incidence of bleeding adverse events, 0.8% pre guidelines versus 0.4% post (<i>P</i> = 1.0). <b>Conclusion:</b> Implementation of the 2019 SIR guidelines for periprocedural management of bleeding risk in patients undergoing percutaneous ultrasound guided liver biopsy did not result in an increase in bleeding adverse events or pre-procedural transfusion rates. The guidelines can be safely implemented in clinical practice with no increase in major adverse events.</p>","PeriodicalId":55290,"journal":{"name":"Canadian Association of Radiologists Journal-Journal De L Association Canadienne Des Radiologistes","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Association of Radiologists Journal-Journal De L Association Canadienne Des Radiologistes","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/08465371241252059","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate if implementation of the 2019 Society of Interventional Radiology (SIR) guidelines for periprocedural management of bleeding risk in patients undergoing percutaneous ultrasound guided liver biopsy is associated with increased haemorrhagic adverse events, change in pre-procedural blood product utilization, and evaluation of guideline compliance rate at a single academic institution. Methods: Ultrasound guided percutaneous liver biopsies from (January 2019-January 2023) were retrospectively reviewed (n = 504), comparing biopsies performed using the 2012 SIR pre-procedural coagulation guidelines (n = 266) to those after implementation of the 2019 SIR pre-procedural guidelines (n = 238). Demographic, preprocedural transfusion, laboratory, and clinical data were reviewed. Chart review was conducted to evaluate the incidence of major bleeding adverse events defined as those resulting in transfusion, embolization, surgery, or death. Results: Implementation of the 2019 SIR periprocedural guidelines resulted in reduced guideline non-compliance related to the administration of blood products, from 5.3% to 1.7% (P = .01). The rate of pre-procedural transfusion remained the same pre and post guidelines at 0.8%. There was no statistically significant change in the incidence of bleeding adverse events, 0.8% pre guidelines versus 0.4% post (P = 1.0). Conclusion: Implementation of the 2019 SIR guidelines for periprocedural management of bleeding risk in patients undergoing percutaneous ultrasound guided liver biopsy did not result in an increase in bleeding adverse events or pre-procedural transfusion rates. The guidelines can be safely implemented in clinical practice with no increase in major adverse events.
期刊介绍:
The Canadian Association of Radiologists Journal is a peer-reviewed, Medline-indexed publication that presents a broad scientific review of radiology in Canada. The Journal covers such topics as abdominal imaging, cardiovascular radiology, computed tomography, continuing professional development, education and training, gastrointestinal radiology, health policy and practice, magnetic resonance imaging, musculoskeletal radiology, neuroradiology, nuclear medicine, pediatric radiology, radiology history, radiology practice guidelines and advisories, thoracic and cardiac imaging, trauma and emergency room imaging, ultrasonography, and vascular and interventional radiology. Article types considered for publication include original research articles, critically appraised topics, review articles, guest editorials, pictorial essays, technical notes, and letter to the Editor.