H. Sekkat, K. Elmansouri, A. Khallouqi, A. Halimi, O. El rhazouani, Z. Tahiri, M. Talbi, M. El Mansouri
{"title":"Characterizing Pediatric Head Patient Size in Moroccan Population: Establishing Age-Dependent Relationships for Accurate CT Dose Estimation","authors":"H. Sekkat, K. Elmansouri, A. Khallouqi, A. Halimi, O. El rhazouani, Z. Tahiri, M. Talbi, M. El Mansouri","doi":"10.1051/radiopro/2024017","DOIUrl":null,"url":null,"abstract":"Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 years, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"127 41","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1051/radiopro/2024017","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 years, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.