A Case Report of Arrhythmia Caused by Skin Expander Implantation

Qiong Liu, Bing Jiang, Hui Jiang, Bin Nie
{"title":"A Case Report of Arrhythmia Caused by Skin Expander Implantation","authors":"Qiong Liu, Bing Jiang, Hui Jiang, Bin Nie","doi":"10.59958/hsf.6705","DOIUrl":null,"url":null,"abstract":"A 51-year-old female patient suffered facial burns during her youth. Following the healing of the wound, a skin expander was implanted on 7 December 2021 to address scar contracture. The preoperative electrocardiogram (ECG) indicated sinus rhythm within the normal range. Color Doppler ultrasound revealed no abnormalities. The patient had no history of hypertension, heart disease, diabetes, arrhythmia, or other cardiovascular and cerebrovascular conditions. On 16 June 2022, the skin expander was removed, and facial scar resection was performed. The routine ECG showed ventricular premature beats. During the operation, when the surgeon pulled and compressed the neck dilator, significant arrhythmia was observed, with the heart rate dropping below 50 beats per minute and frequent ventricular premature beats occurring. The surgeon promptly halted the procedure, resulting in immediate relief of the patient's pain. Subsequently, the ventricular premature beats ceased, and normal sinus rhythm was restored. Once the heart rate exceeded 60 beats per minute, the surgeon resumed the operation, but ventricular premature beats persisted. After removing the dilator, the heart rate gradually returned to normal, and no further arrhythmia occurred. The patient recovered smoothly post-operation, with stable vital signs and no reported discomfort. She safely returned to the ward. It was determined that the patient's arrhythmia was caused by the compression of the carotid sinus due to the stretching of the neck dilator.","PeriodicalId":503802,"journal":{"name":"The Heart Surgery Forum","volume":"21 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Heart Surgery Forum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.59958/hsf.6705","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A 51-year-old female patient suffered facial burns during her youth. Following the healing of the wound, a skin expander was implanted on 7 December 2021 to address scar contracture. The preoperative electrocardiogram (ECG) indicated sinus rhythm within the normal range. Color Doppler ultrasound revealed no abnormalities. The patient had no history of hypertension, heart disease, diabetes, arrhythmia, or other cardiovascular and cerebrovascular conditions. On 16 June 2022, the skin expander was removed, and facial scar resection was performed. The routine ECG showed ventricular premature beats. During the operation, when the surgeon pulled and compressed the neck dilator, significant arrhythmia was observed, with the heart rate dropping below 50 beats per minute and frequent ventricular premature beats occurring. The surgeon promptly halted the procedure, resulting in immediate relief of the patient's pain. Subsequently, the ventricular premature beats ceased, and normal sinus rhythm was restored. Once the heart rate exceeded 60 beats per minute, the surgeon resumed the operation, but ventricular premature beats persisted. After removing the dilator, the heart rate gradually returned to normal, and no further arrhythmia occurred. The patient recovered smoothly post-operation, with stable vital signs and no reported discomfort. She safely returned to the ward. It was determined that the patient's arrhythmia was caused by the compression of the carotid sinus due to the stretching of the neck dilator.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
皮肤扩张器植入引发心律失常的病例报告
一名 51 岁的女性患者在年轻时面部烧伤。伤口愈合后,于 2021 年 12 月 7 日植入了皮肤扩张器,以解决疤痕挛缩问题。术前心电图(ECG)显示窦性心律在正常范围内。彩色多普勒超声检查未发现异常。患者无高血压、心脏病、糖尿病、心律失常或其他心脑血管疾病史。2022 年 6 月 16 日,取出了皮肤扩张器,并进行了面部疤痕切除术。常规心电图显示室性早搏。在手术过程中,当外科医生拉压颈部扩张器时,观察到明显的心律失常,心率降至每分钟 50 次以下,并频繁出现室性早搏。外科医生立即停止了手术,病人的疼痛立即得到缓解。随后,室性早搏停止,窦性心律恢复正常。当心率超过每分钟 60 次时,外科医生恢复了手术,但室性早搏依然存在。取出扩张器后,心率逐渐恢复正常,也没有再出现心律失常。患者术后恢复顺利,生命体征平稳,没有不适症状。她安全返回病房。经确定,患者的心律失常是由于颈部扩张器的拉伸压迫颈动脉窦引起的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Influence of Serum Apelin and CD40L Expression Levels on Adverse Cardiovascular Events after PCI Effects of Mindfulness Meditation on Anxiety, Self-Efficacy, and Quality of Life in Patients after Coronary Artery Bypass Transplantation Anomalous Origin of the Right Pulmonary Artery from the Ascending Aorta in a 10-Day-Old Boy: A Case Report Surgical Repair of Giant Dissecting Pulmonary Artery Aneurysm Associated with Atrial Septal Defect and Pulmonary Arterial Hypertension: A Case Report Rhythm or Blues: Managing the Electrical State of the Heart with Temporary Pacing Wires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1