Performance of modified colistin broth disc elution vis-a-vis broth microdilution method for susceptibility testing of Enterobacterales

IF 0.9 Q3 MEDICINE, GENERAL & INTERNAL Journal of Laboratory Physicians Pub Date : 2024-05-06 DOI:10.25259/jlp-2023-5-25-(1801)
P. Kar, A. Mahapatra, Bilal Ahmad Malik, B. Behera, Srujana Mohanty
{"title":"Performance of modified colistin broth disc elution vis-a-vis broth microdilution method for susceptibility testing of Enterobacterales","authors":"P. Kar, A. Mahapatra, Bilal Ahmad Malik, B. Behera, Srujana Mohanty","doi":"10.25259/jlp-2023-5-25-(1801)","DOIUrl":null,"url":null,"abstract":"\n\nRecently, Clinical and Laboratory Standards Institute (CLSI) has approved colistin broth disc elution (CBDE) to be a supplemental test. This requires multiple discs and tubes to get the desired concentrations of colistin -1, 2, and 4 µg/mL and 10 mL volume of cation-adjusted Mueller–Hinton broth for a single isolate. The present study was aimed to evaluate the performance of CBDE in a microtiter plate format modified (mCBDE) with the reference method broth microdilution (BMD) for detection of colistin resistance in carbapenem-resistant Enterobacterales (CRE) isolates.\n\n\n\nOne hundred and sixty non-duplicate clinical CRE isolates (May 2021–April 2022) were simultaneously subjected for BMD and mCBDE. For mCBDE, colistin 10 µg discs and Mueller–Hinton broth no-2 control cations were procured from HiMedia, Mumbai, and drug concentrations were prepared following CLSI-M100Ed31. Results of mCBDE were compared with reference BMD (Minimum inhibitory concentration [MIC] ≤2 µg/mL – intermediate and ≥4 µg/mL – resistant).\n\n\n\nThe performance of mCBDE was compared with BMD and expressed in terms of Categorical, essential agreement (EA), very major error (VME), and major error (ME). The sensitivity and specificity were calculated using Fisher’s contingency Table.\n\n\n\nOf the 160 CRE isolates, 152 had exactly the same minimal inhibitory concentration (MIC) in both the tests with four isolates having higher and four having lower colistin MIC by mCBDE, giving a major error of 2.1% and VME of 5.5%. Categorical and essential agreement of mCBDE were 97.5% and 98.7%, respectively.\n\n\n\nmCBDE is an easy, economical, and reliable alternative test for determining colistin susceptibility for CRE isolates. Further, large-scale study is needed to strengthen our observation.\n","PeriodicalId":16149,"journal":{"name":"Journal of Laboratory Physicians","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Laboratory Physicians","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/jlp-2023-5-25-(1801)","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Recently, Clinical and Laboratory Standards Institute (CLSI) has approved colistin broth disc elution (CBDE) to be a supplemental test. This requires multiple discs and tubes to get the desired concentrations of colistin -1, 2, and 4 µg/mL and 10 mL volume of cation-adjusted Mueller–Hinton broth for a single isolate. The present study was aimed to evaluate the performance of CBDE in a microtiter plate format modified (mCBDE) with the reference method broth microdilution (BMD) for detection of colistin resistance in carbapenem-resistant Enterobacterales (CRE) isolates. One hundred and sixty non-duplicate clinical CRE isolates (May 2021–April 2022) were simultaneously subjected for BMD and mCBDE. For mCBDE, colistin 10 µg discs and Mueller–Hinton broth no-2 control cations were procured from HiMedia, Mumbai, and drug concentrations were prepared following CLSI-M100Ed31. Results of mCBDE were compared with reference BMD (Minimum inhibitory concentration [MIC] ≤2 µg/mL – intermediate and ≥4 µg/mL – resistant). The performance of mCBDE was compared with BMD and expressed in terms of Categorical, essential agreement (EA), very major error (VME), and major error (ME). The sensitivity and specificity were calculated using Fisher’s contingency Table. Of the 160 CRE isolates, 152 had exactly the same minimal inhibitory concentration (MIC) in both the tests with four isolates having higher and four having lower colistin MIC by mCBDE, giving a major error of 2.1% and VME of 5.5%. Categorical and essential agreement of mCBDE were 97.5% and 98.7%, respectively. mCBDE is an easy, economical, and reliable alternative test for determining colistin susceptibility for CRE isolates. Further, large-scale study is needed to strengthen our observation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
改良的可乐定肉汤圆盘洗脱法与肉汤微量稀释法在肠杆菌药敏试验中的性能比较
最近,临床与实验室标准协会(CLSI)批准将秋水仙素肉汤洗脱(CBDE)作为一项补充检测。对于单个分离物来说,这需要多个圆盘和试管以及 10 毫升阳离子调整的穆勒-欣顿肉汤来获得所需的浓度-1、2 和 4 微克/毫升的秋水仙素。本研究旨在评估改良微孔板格式的 CBDE(mCBDE)与肉汤微量稀释法(BMD)在检测耐碳青霉烯类肠杆菌(CRE)分离物的可乐定耐药性方面的性能。对于 mCBDE,从孟买 HiMedia 公司购买了可乐定 10 µg 盘和 Mueller-Hinton 肉汤 No-2 对照阳离子,并按照 CLSI-M100Ed31 配制了药物浓度。mCBDE 的结果与参考 BMD(最低抑菌浓度 [MIC] ≤2 µg/mL - 中度和 ≥4 µg/mL - 耐药)进行了比较。mCBDE 的性能与 BMD 进行了比较,用分类、基本一致 (EA)、非常大误差 (VME) 和大误差 (ME) 表示。在 160 个 CRE 分离物中,有 152 个在两种测试中的最小抑菌浓度 (MIC) 完全相同,其中 4 个分离物的 mCBDE MIC 较高,4 个较低,主要误差为 2.1%,VME 为 5.5%。mCBDE 是确定 CRE 分离物对可乐定敏感性的一种简便、经济、可靠的替代检测方法。我们需要进一步开展大规模研究,以加强我们的观察结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Laboratory Physicians
Journal of Laboratory Physicians MEDICINE, GENERAL & INTERNAL-
自引率
0.00%
发文量
99
审稿时长
31 weeks
期刊最新文献
Experience of rigorous practice of antimicrobial stewardship program and its impact on antibiotic consumption A new era for Journal of Laboratory Physicians Sensitivity and specificity of newly generated monoclonal antibodies to detect novel antigens of Mycobacterium tuberculosis for the diagnosis of all forms of tuberculosis Martin’s formula is best to calculate low-density lipoprotein cholesterol Performance of modified colistin broth disc elution vis-a-vis broth microdilution method for susceptibility testing of Enterobacterales
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1