{"title":"Fire Behaviour of Damaged Wood-Steel-Wood Beam Connections Retrofitted with Self-Tapping Screws – Experimental study","authors":"Mohamed Hegazi, Osama (Sam) Salem","doi":"10.1139/cjce-2023-0442","DOIUrl":null,"url":null,"abstract":"This experimental study aimed to investigate the structural fire behaviour of damaged glulam beam connections retrofitted using self-tapping screws (STS). Four full-size glulam beam-end bolted connections with wood-steel-wood connection configurations were examined using four or six bolts arranged in two different bolt patterns. All connections were retrofitted using STS after being deliberately damaged through physical testing until failure. In a subsequent stage, the retrofitted connections were experimentally tested under standard fire exposure while subjected to the maximum design load of the weakest, undamaged, unreinforced connection configuration. The influence of the application of STS in terms of preventing wood-splitting propagation and maintaining reasonable fire resistance for the retrofitted connections was experimentally investigated and proven in this study. Results show that the retrofitted glulam beam connections maintained a minimum of approximately 67% of the failure time of identical but undamaged, unreinforced connections under standard fire exposure.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"26 9","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-05-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1139/cjce-2023-0442","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
This experimental study aimed to investigate the structural fire behaviour of damaged glulam beam connections retrofitted using self-tapping screws (STS). Four full-size glulam beam-end bolted connections with wood-steel-wood connection configurations were examined using four or six bolts arranged in two different bolt patterns. All connections were retrofitted using STS after being deliberately damaged through physical testing until failure. In a subsequent stage, the retrofitted connections were experimentally tested under standard fire exposure while subjected to the maximum design load of the weakest, undamaged, unreinforced connection configuration. The influence of the application of STS in terms of preventing wood-splitting propagation and maintaining reasonable fire resistance for the retrofitted connections was experimentally investigated and proven in this study. Results show that the retrofitted glulam beam connections maintained a minimum of approximately 67% of the failure time of identical but undamaged, unreinforced connections under standard fire exposure.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.