Gaiping Zhao , Zhehua Jiang , Eryun Chen , Tong Ma , Jie Wu , Chengli Song , Weiqi Li
{"title":"Biomechanical investigation of a customized interspinous spacer system in the treatment of degenerative disc diseases: A finite element analysis","authors":"Gaiping Zhao , Zhehua Jiang , Eryun Chen , Tong Ma , Jie Wu , Chengli Song , Weiqi Li","doi":"10.1016/j.clinbiomech.2024.106270","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>A novel interspinous fixation system based on anatomical parameters and incorporating transfacetopedicular screws, was developed to treat degenerative disc diseases. The biomechanical characteristics of the novel system were evaluated using finite element analysis in comparison to other classical interspinous spacers.</p></div><div><h3>Methods</h3><p>The L1-S1 lumbar spine finite element models were surgically implanted with the novel system, Coflex and DIAM devices at the L4/L5 segment to assess the range of motion, the pression distribution of intervertebral disc, the peak stresses on the spinous process and implant during various motions.</p></div><div><h3>Findings</h3><p>Range of motions of the L4/L5 surgical segment were reduced by 29.13%, 61.27%, 77.35%, 33.33%, and the peak stresses of intervertebral disc were decreased by 36.82%, 67.31%, 73.00%, 69.57% for the novel system in flexion, extension, lateral bending, and axial rotation when compared with the Coflex, and they were declined by 34.53%, 57.86%, 75.81%, 25.21%; 36.22%, 67.31%, 75.01%, 71.40% compared with DIAM. The maximum stresses of the spinous process were 29.93 MPa, 24.66 MPa, 14.45 MPa, 24.37 MPa in the novel system, and those of Coflex and DIAM were 165.3 MPa, 109 MPa, 84.79 MPa, 47.66 MPa and 52.59 MPa, 48.78 MPa, 50.27 MPa, 44.16 MPa during the same condition.</p></div><div><h3>Interpretation</h3><p>Compared to other interspinous spacer devices, the novel interspinous fixation system demonstrated excellent stability, effectively distributing load on the intervertebral disc, and reducing the risk of spinous process fractures. The personalized design of the novel interspinous fixation system could be a viable option for treating degenerative disc diseases.</p></div>","PeriodicalId":50992,"journal":{"name":"Clinical Biomechanics","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0268003324001025","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background
A novel interspinous fixation system based on anatomical parameters and incorporating transfacetopedicular screws, was developed to treat degenerative disc diseases. The biomechanical characteristics of the novel system were evaluated using finite element analysis in comparison to other classical interspinous spacers.
Methods
The L1-S1 lumbar spine finite element models were surgically implanted with the novel system, Coflex and DIAM devices at the L4/L5 segment to assess the range of motion, the pression distribution of intervertebral disc, the peak stresses on the spinous process and implant during various motions.
Findings
Range of motions of the L4/L5 surgical segment were reduced by 29.13%, 61.27%, 77.35%, 33.33%, and the peak stresses of intervertebral disc were decreased by 36.82%, 67.31%, 73.00%, 69.57% for the novel system in flexion, extension, lateral bending, and axial rotation when compared with the Coflex, and they were declined by 34.53%, 57.86%, 75.81%, 25.21%; 36.22%, 67.31%, 75.01%, 71.40% compared with DIAM. The maximum stresses of the spinous process were 29.93 MPa, 24.66 MPa, 14.45 MPa, 24.37 MPa in the novel system, and those of Coflex and DIAM were 165.3 MPa, 109 MPa, 84.79 MPa, 47.66 MPa and 52.59 MPa, 48.78 MPa, 50.27 MPa, 44.16 MPa during the same condition.
Interpretation
Compared to other interspinous spacer devices, the novel interspinous fixation system demonstrated excellent stability, effectively distributing load on the intervertebral disc, and reducing the risk of spinous process fractures. The personalized design of the novel interspinous fixation system could be a viable option for treating degenerative disc diseases.
期刊介绍:
Clinical Biomechanics is an international multidisciplinary journal of biomechanics with a focus on medical and clinical applications of new knowledge in the field.
The science of biomechanics helps explain the causes of cell, tissue, organ and body system disorders, and supports clinicians in the diagnosis, prognosis and evaluation of treatment methods and technologies. Clinical Biomechanics aims to strengthen the links between laboratory and clinic by publishing cutting-edge biomechanics research which helps to explain the causes of injury and disease, and which provides evidence contributing to improved clinical management.
A rigorous peer review system is employed and every attempt is made to process and publish top-quality papers promptly.
Clinical Biomechanics explores all facets of body system, organ, tissue and cell biomechanics, with an emphasis on medical and clinical applications of the basic science aspects. The role of basic science is therefore recognized in a medical or clinical context. The readership of the journal closely reflects its multi-disciplinary contents, being a balance of scientists, engineers and clinicians.
The contents are in the form of research papers, brief reports, review papers and correspondence, whilst special interest issues and supplements are published from time to time.
Disciplines covered include biomechanics and mechanobiology at all scales, bioengineering and use of tissue engineering and biomaterials for clinical applications, biophysics, as well as biomechanical aspects of medical robotics, ergonomics, physical and occupational therapeutics and rehabilitation.