{"title":"The Italian external quality assessment program for Cystic Fibrosis sweat chloride test: CFTR modulators and the impact of a new sweat test report form","authors":"Natalia Cirilli , Giovanna Floridia , Annalisa Amato , Rita Padoan , Federica Censi , Gianluca Ferrari , Valeria Raia , Giuseppe Castaldo , Ettore Capoluongo , Domenica Taruscio , Marco Salvatore","doi":"10.1016/j.plabm.2024.e00403","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>The advent of CFTR modulators highlighted that the sweat test (ST) for CF can be used also as an outcome measure for the basic defect of CFTR. Despite the technological advances, ST still remains operator-dependent and its execution should be strongly paired with guidelines. In 2022, due to the advent of CFTR modulators, the Italian CF Society introduced a specific ST report. The aim of the present paper is to discuss the impact of this new report in the 2022-23 round of the Italian External Quality Assessment program for ST (I-EQA-SCT).</p></div><div><h3>Methods</h3><p>The scheme of the I-EQA-SCT is prospective, enrolment is voluntary, the payment of a fee is required and results are shared through a web-facility. Assessment covers analysis, interpretation, and reporting of results. In the 2022-23 round, 2 out of the 3 mock clinical information referred to patients who started modulators.</p></div><div><h3>Results</h3><p>Fourteen laboratories completed the 2022-23 I-EQA-SCT round. Three of them failed in the interpretation of results from these two mock cases and/or used a wrong report not consistent with the more recent Italian Sweat Test Recommendations.</p></div><div><h3>Conclusions</h3><p>The overall results obtained from the laboratories involved in the I-EQA-SCT program clearly showed that the laboratories’ qualitative and quantitative performance improved significantly. Results emerged from this round highlighted an issue in the report form used for monitoring patients on CFTR modulator therapy thus stressing the importance of these programs in improving both the performance of lab services and ameliorating the sweat test recommendations.</p></div>","PeriodicalId":20421,"journal":{"name":"Practical Laboratory Medicine","volume":"40 ","pages":"Article e00403"},"PeriodicalIF":1.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2352551724000490/pdfft?md5=0d971d899d8456940875725a0c6bb72f&pid=1-s2.0-S2352551724000490-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2352551724000490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
The advent of CFTR modulators highlighted that the sweat test (ST) for CF can be used also as an outcome measure for the basic defect of CFTR. Despite the technological advances, ST still remains operator-dependent and its execution should be strongly paired with guidelines. In 2022, due to the advent of CFTR modulators, the Italian CF Society introduced a specific ST report. The aim of the present paper is to discuss the impact of this new report in the 2022-23 round of the Italian External Quality Assessment program for ST (I-EQA-SCT).
Methods
The scheme of the I-EQA-SCT is prospective, enrolment is voluntary, the payment of a fee is required and results are shared through a web-facility. Assessment covers analysis, interpretation, and reporting of results. In the 2022-23 round, 2 out of the 3 mock clinical information referred to patients who started modulators.
Results
Fourteen laboratories completed the 2022-23 I-EQA-SCT round. Three of them failed in the interpretation of results from these two mock cases and/or used a wrong report not consistent with the more recent Italian Sweat Test Recommendations.
Conclusions
The overall results obtained from the laboratories involved in the I-EQA-SCT program clearly showed that the laboratories’ qualitative and quantitative performance improved significantly. Results emerged from this round highlighted an issue in the report form used for monitoring patients on CFTR modulator therapy thus stressing the importance of these programs in improving both the performance of lab services and ameliorating the sweat test recommendations.
期刊介绍:
Practical Laboratory Medicine is a high-quality, peer-reviewed, international open-access journal publishing original research, new methods and critical evaluations, case reports and short papers in the fields of clinical chemistry and laboratory medicine. The objective of the journal is to provide practical information of immediate relevance to workers in clinical laboratories. The primary scope of the journal covers clinical chemistry, hematology, molecular biology and genetics relevant to laboratory medicine, microbiology, immunology, therapeutic drug monitoring and toxicology, laboratory management and informatics. We welcome papers which describe critical evaluations of biomarkers and their role in the diagnosis and treatment of clinically significant disease, validation of commercial and in-house IVD methods, method comparisons, interference reports, the development of new reagents and reference materials, reference range studies and regulatory compliance reports. Manuscripts describing the development of new methods applicable to laboratory medicine (including point-of-care testing) are particularly encouraged, even if preliminary or small scale.