{"title":"P.050 Spike source localizations between the three non-REM sleep stages: resemblances to wakefulness and distinctions from REM sleep","authors":"A. Hatamzadeh, M. Hasen, M. Ng","doi":"10.1017/cjn.2024.157","DOIUrl":null,"url":null,"abstract":"Background: Sleep-wake states (SWS) affect the expression of interictal epileptiform discharges (“spikes”), which affects resultant source localization calculations used in epilepsy evaluation. We hypothesize that spike localizations from non-REM sleep 1-3 are most concordant with one another. Methods: We used Standardized low-resolution brain electromagnetic tomography (sLORETA) in Curry 8 software to calculate source localization voxels of spikes in N1-3, REM, or wakefulness (W). We assessed voxel concordance between N1-N2-N3/N1-N2-W/N1-N3-W/N2-N3-W/REM-N1-N2/REM-N1-N3/REM-N2-N3/REM-N1-W/REM-N2-W/REM-N3-W. We classified concordances into those containing and not containing a SWS (e.g. N1 vs. not-N1 = N1-N2-N3/N1-N2-W/N1-N3-W/REM-N1-N2/REM-N1-N3/REM-N1-W vs. REM-N2-W/REM-N3-W/REM-N2-N3/N2-N3-W) for comparison. Results: Concordances did not differ for N1-3 or W. However, concordances with REM were lower than those without REM as a fraction of source localization space (median 32.1% vs. 56.1%, p<0.001) and cortical grey matter (median 20.4% vs. 27.3%, p=0.003). Conclusions: As expected, source localizations from spikes in N1, N2, and N3 did not significantly differ from one another because these three states are constituent members of non-REM sleep. Surprisingly, however, source localizations derived from awake spikes – not a constituent of non-REM sleep – also did not differ. In contrast, REM was most different by reproducibly exhibiting the least three-way concordance. These findings reinforce the unique localizing ability of REM sleep.","PeriodicalId":9571,"journal":{"name":"Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques","volume":"65 14","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/cjn.2024.157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Sleep-wake states (SWS) affect the expression of interictal epileptiform discharges (“spikes”), which affects resultant source localization calculations used in epilepsy evaluation. We hypothesize that spike localizations from non-REM sleep 1-3 are most concordant with one another. Methods: We used Standardized low-resolution brain electromagnetic tomography (sLORETA) in Curry 8 software to calculate source localization voxels of spikes in N1-3, REM, or wakefulness (W). We assessed voxel concordance between N1-N2-N3/N1-N2-W/N1-N3-W/N2-N3-W/REM-N1-N2/REM-N1-N3/REM-N2-N3/REM-N1-W/REM-N2-W/REM-N3-W. We classified concordances into those containing and not containing a SWS (e.g. N1 vs. not-N1 = N1-N2-N3/N1-N2-W/N1-N3-W/REM-N1-N2/REM-N1-N3/REM-N1-W vs. REM-N2-W/REM-N3-W/REM-N2-N3/N2-N3-W) for comparison. Results: Concordances did not differ for N1-3 or W. However, concordances with REM were lower than those without REM as a fraction of source localization space (median 32.1% vs. 56.1%, p<0.001) and cortical grey matter (median 20.4% vs. 27.3%, p=0.003). Conclusions: As expected, source localizations from spikes in N1, N2, and N3 did not significantly differ from one another because these three states are constituent members of non-REM sleep. Surprisingly, however, source localizations derived from awake spikes – not a constituent of non-REM sleep – also did not differ. In contrast, REM was most different by reproducibly exhibiting the least three-way concordance. These findings reinforce the unique localizing ability of REM sleep.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
P.050 三个非快速眼动睡眠阶段之间的尖峰源定位:与清醒的相似之处以及与快速眼动睡眠的区别
背景:睡眠-觉醒状态(SWS)会影响发作间期癫痫样放电("尖峰")的表现,从而影响癫痫评估中使用的源定位计算结果。我们假设,非快速眼动睡眠 1-3 阶段的尖峰定位彼此最为一致。方法:我们使用 Curry 8 软件中的标准化低分辨率脑电磁断层扫描(sLORETA)来计算 N1-3、REM 或清醒(W)状态下尖峰的源定位体素。我们评估了 N1-N2-N3/N1-N2-W/N1-N3-W/N2-N3-W/REM-N1-N2/REM-N1-N3/REM-N2-N3/REM-N1-W/REM-N2-W/REM-N3-W 之间的体素一致性。我们将并列关系分为包含和不包含 SWS 的并列关系(例如,N1 与非 N1 = N1-N2-N3/N1-N2-W/N1-N3-W/REM-N1-N2/REM-N1-N3/REM-N1-W 与 REM-N2-W/REM-N3-W/REM-N2-N3/N2-N3-W ),以便进行比较。结果然而,就源定位空间(中位数为 32.1% vs. 56.1%,p<0.001)和皮层灰质(中位数为 20.4% vs. 27.3%,p=0.003)的比例而言,有快速眼动仪的一致性低于无快速眼动仪的一致性。结论正如预期的那样,N1、N2 和 N3 的尖峰源定位相互之间没有显著差异,因为这三种状态是非快速眼动睡眠的组成成员。然而,令人惊讶的是,来自清醒尖峰(非快速眼动睡眠的组成部分)的源定位也没有差异。与此相反,快速眼动睡眠的差异最大,因为它可重复地表现出最少的三方一致性。这些发现加强了快速眼动睡眠的独特定位能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
B.2 Time from symptom onset and number of health care encounters prior to diagnosis of cerebral venous thrombosis D.6 Neurological care and outcomes of pregnant patients with epilepsy in a Canadian tertiary care center (2014-2020) F.4 Anatomical assessment and comparative analysis of ventricular access points in pterional approach: a cadaveric study P.077 Reducing artifact during in bi-directional brain interfacing P.006 Barriers and risk factors for emergency room visits vs smartphone app use for migraine in Canada and the United States
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1