Assessment of Bridging Stents in In Situ Laser Fenestrations of Aortic Endografts With Intravascular Ultrasound

IF 1.4 Q3 PERIPHERAL VASCULAR DISEASE EJVES Vascular Forum Pub Date : 2024-01-01 DOI:10.1016/j.ejvsvf.2024.05.008
David Lindström , Anders Wanhainen , Kevin Mani , Giuseppe Asciutto
{"title":"Assessment of Bridging Stents in In Situ Laser Fenestrations of Aortic Endografts With Intravascular Ultrasound","authors":"David Lindström ,&nbsp;Anders Wanhainen ,&nbsp;Kevin Mani ,&nbsp;Giuseppe Asciutto","doi":"10.1016/j.ejvsvf.2024.05.008","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Treatment of complex aortic aneurysms with the <em>in situ</em> laser fenestration (ISLF) technique involves implantation of a balloon expandable stent graft (bSG) in the created fenestration. Adequate expansion of this bSG is of importance both to achieve seal and to ensure target vessel stability. This experimental study assessed the expansion rate of different bSGs in the ISLF setting using intravascular ultrasound (IVUS).</p></div><div><h3>Methods</h3><p>A commercially available aortic endograft was used to test the laser fenestration technique (Zenith Alpha, Cook Medical LLC, Bloomington, IN, USA). The ISLF was stented with the following bSGs: two Gore Viabahn VBX balloon expandable endoprostheses (WL Gore &amp; Associates, Bloomington, IL, USA), three BeGraft Peripheral and three BeGraft Plus (Bentley InnoMed GmbH; Hechingen, Germany), and three Advanta V12 (Atrium, Hudson, NH, USA). The bSGs were expanded in three steps: (1) nominal, (2) rated burst pressure, and (3) dilation with a non-compliant balloon at 15 atmospheres. After each step, an IVUS assessment of the bSG minimum diameter and the area at the fenestration (FA) and in a fully expanded segment distal to the fenestration (SA) was performed. A mean of the three IVUS measurements was used as the value for comparison. An insufficient bSG expansion was defined as a mean of FA/SA of &lt;0.8 (i.e., &lt;80% expansion).</p></div><div><h3>Results</h3><p>The VBX was the only bSG that could be expanded to its intended diameter (i.e., at least 80%) at nominal pressure. The BeGraft Peripheral and BeGraft Plus had the lowest degree of expansion after nominal and rated burst pressure. All bSGs that were tested reached a sufficient expansion degree after using a higher pressure balloon.</p></div><div><h3>Conclusion</h3><p>In this <em>ex vivo</em> experiment, dilation up to nominal pressure showed satisfactory expansion only for the VBX. The consistency of the results when applied to the different types of stent grafts that were analysed reflects structural stent graft specific issues to consider when choosing the right device in cases of ISLF.</p></div>","PeriodicalId":36502,"journal":{"name":"EJVES Vascular Forum","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666688X24000881/pdfft?md5=719ca6a7767179f9a56672f94e760625&pid=1-s2.0-S2666688X24000881-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJVES Vascular Forum","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666688X24000881","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

Treatment of complex aortic aneurysms with the in situ laser fenestration (ISLF) technique involves implantation of a balloon expandable stent graft (bSG) in the created fenestration. Adequate expansion of this bSG is of importance both to achieve seal and to ensure target vessel stability. This experimental study assessed the expansion rate of different bSGs in the ISLF setting using intravascular ultrasound (IVUS).

Methods

A commercially available aortic endograft was used to test the laser fenestration technique (Zenith Alpha, Cook Medical LLC, Bloomington, IN, USA). The ISLF was stented with the following bSGs: two Gore Viabahn VBX balloon expandable endoprostheses (WL Gore & Associates, Bloomington, IL, USA), three BeGraft Peripheral and three BeGraft Plus (Bentley InnoMed GmbH; Hechingen, Germany), and three Advanta V12 (Atrium, Hudson, NH, USA). The bSGs were expanded in three steps: (1) nominal, (2) rated burst pressure, and (3) dilation with a non-compliant balloon at 15 atmospheres. After each step, an IVUS assessment of the bSG minimum diameter and the area at the fenestration (FA) and in a fully expanded segment distal to the fenestration (SA) was performed. A mean of the three IVUS measurements was used as the value for comparison. An insufficient bSG expansion was defined as a mean of FA/SA of <0.8 (i.e., <80% expansion).

Results

The VBX was the only bSG that could be expanded to its intended diameter (i.e., at least 80%) at nominal pressure. The BeGraft Peripheral and BeGraft Plus had the lowest degree of expansion after nominal and rated burst pressure. All bSGs that were tested reached a sufficient expansion degree after using a higher pressure balloon.

Conclusion

In this ex vivo experiment, dilation up to nominal pressure showed satisfactory expansion only for the VBX. The consistency of the results when applied to the different types of stent grafts that were analysed reflects structural stent graft specific issues to consider when choosing the right device in cases of ISLF.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用血管内超声评估主动脉内移植物原位激光瘘中的桥接支架
目的使用原位激光瓣膜术(ISLF)治疗复杂的主动脉瘤时,需要在形成的瓣膜中植入球囊扩张支架移植物(bSG)。bSG 的充分扩张对于实现密封和确保目标血管的稳定性都非常重要。本实验研究使用血管内超声(IVUS)评估了不同 bSG 在 ISLF 设置中的扩张率。方法使用市售主动脉内膜移植物测试激光栅栏技术(Zenith Alpha,Cook Medical LLC,美国印第安纳州布鲁明顿)。ISLF 用以下 bSG 做了支架:两个 Gore Viabahn VBX 球囊扩张内膜(WL Gore & Associates, Bloomington, IL, USA)、三个 BeGraft Peripheral 和三个 BeGraft Plus(Bentley InnoMed GmbH; Hechingen, Germany)以及三个 Advanta V12(Atrium, Hudson, NH, USA)。bSG 分三步扩增:(1)标称压力,(2)额定爆破压力,(3)用 15 个大气压的非顺应性球囊扩张。每个步骤结束后,都要对 bSG 的最小直径、栅栏(FA)处的面积以及栅栏远端完全扩张段(SA)的面积进行 IVUS 评估。三个 IVUS 测量值的平均值作为比较值。结果 VBX 是唯一能在额定压力下扩张到预期直径(即至少 80%)的 bSG。BeGraft Peripheral 和 BeGraft Plus 在标称和额定爆破压力下的膨胀程度最低。结论在这项体内外实验中,只有 VBX 在扩张到额定压力时才显示出令人满意的扩张效果。在分析不同类型的支架移植物时,结果的一致性反映了在 ISLF 病例中选择正确装置时需要考虑的支架移植物结构特定问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
EJVES Vascular Forum
EJVES Vascular Forum Medicine-Surgery
CiteScore
1.50
自引率
0.00%
发文量
145
审稿时长
102 days
期刊最新文献
Leiomyoma: Not So Smooth Editorial Board Editorial Board Immediate Carotid Artery Stenting or Deferred Treatment in Patients With Tandem Carotid Lesions Treated Endovascularly for Acute Ischaemic Stroke Critical Limb Ischaemia in Octogenarians: Treatment Outcomes Compared With Younger Patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1