Correlation between serum vitamin D levels and bone mass density evaluated by radiofrequency echographic multi-spectrometry technology (REMS) in menopausal women.

Narra J Pub Date : 2024-04-01 Epub Date: 2024-04-30 DOI:10.52225/narra.v4i1.452
M Fidel G Siregar, Feisal Jabbar, Iman H Effendi, Tanzil Alhair, M Oky Prabudi, Dwi Faradina
{"title":"Correlation between serum vitamin D levels and bone mass density evaluated by radiofrequency echographic multi-spectrometry technology (REMS) in menopausal women.","authors":"M Fidel G Siregar, Feisal Jabbar, Iman H Effendi, Tanzil Alhair, M Oky Prabudi, Dwi Faradina","doi":"10.52225/narra.v4i1.452","DOIUrl":null,"url":null,"abstract":"<p><p>Osteoporosis is a common condition associated with an increased risk of bone fractures due to fragility. Bone mineral density (BMD) is lower in menopausal women due to estrogen deficiency, age-related decline in osteoblast function, decreased calcium absorption, and reduced synthesis of vitamin D, which lead to osteoporosis. The aim of this study was to determine the correlation between serum vitamin D levels and BMD assessed using radiofrequency echographic multi-spectrometry technology (REMS) in menopausal women. A cross-sectional study was conducted at Prof. Dr. Chairuddin P. Lubis Hospital of Universitas Sumatera Utara, Medan, Indonesia, from May 2023 to August 2023. Consecutive sampling method was employed to sample menopausal women with no history of hysterectomy or oophorectomy (unilateral or bilateral), and no history of hormone replacement therapy or vitamin D supplementation. Interviews and physical examinations were conducted to obtain the characteristics of the subjects (age, duration of menopause, and body mass index). The 25(OH)D level was measured using immunoassay and REMS examination was conducted to assess BMD. The Spearman correlation test was used to assess the correlation between serum vitamin D levels and BMD. A total of 32 menopausal women were included in this study with the average vitamin D level was 18.05±5.81 ng/mL, and the mean BMD level was -2.13±1.23. The data showed a significant positive correlation between serum vitamin D levels and BMD in menopausal women (<i>r</i>=0.710; <i>p</i>=0.020). This study highlights that REMS could be useful as an alternative to dual-energy x-ray absorptiometry (DXA) to assess DMD in postmenopausal women.</p>","PeriodicalId":517416,"journal":{"name":"Narra J","volume":"4 1","pages":"e452"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11125322/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Narra J","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52225/narra.v4i1.452","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Osteoporosis is a common condition associated with an increased risk of bone fractures due to fragility. Bone mineral density (BMD) is lower in menopausal women due to estrogen deficiency, age-related decline in osteoblast function, decreased calcium absorption, and reduced synthesis of vitamin D, which lead to osteoporosis. The aim of this study was to determine the correlation between serum vitamin D levels and BMD assessed using radiofrequency echographic multi-spectrometry technology (REMS) in menopausal women. A cross-sectional study was conducted at Prof. Dr. Chairuddin P. Lubis Hospital of Universitas Sumatera Utara, Medan, Indonesia, from May 2023 to August 2023. Consecutive sampling method was employed to sample menopausal women with no history of hysterectomy or oophorectomy (unilateral or bilateral), and no history of hormone replacement therapy or vitamin D supplementation. Interviews and physical examinations were conducted to obtain the characteristics of the subjects (age, duration of menopause, and body mass index). The 25(OH)D level was measured using immunoassay and REMS examination was conducted to assess BMD. The Spearman correlation test was used to assess the correlation between serum vitamin D levels and BMD. A total of 32 menopausal women were included in this study with the average vitamin D level was 18.05±5.81 ng/mL, and the mean BMD level was -2.13±1.23. The data showed a significant positive correlation between serum vitamin D levels and BMD in menopausal women (r=0.710; p=0.020). This study highlights that REMS could be useful as an alternative to dual-energy x-ray absorptiometry (DXA) to assess DMD in postmenopausal women.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过射频回声多谱勒技术(REMS)评估绝经期妇女血清维生素 D 水平与骨质密度之间的相关性。
骨质疏松症是一种常见疾病,由于骨质脆弱,骨折风险增加。由于雌激素缺乏、与年龄相关的成骨细胞功能下降、钙吸收减少以及维生素 D 合成减少,导致骨质疏松症,绝经期妇女的骨矿物质密度(BMD)较低。本研究旨在确定更年期女性血清维生素 D 水平与使用射频回波多谱勒技术(REMS)评估的 BMD 之间的相关性。这项横断面研究于 2023 年 5 月至 2023 年 8 月在印度尼西亚棉兰苏门答腊大学的 Chairuddin P. Lubis 教授医院进行。研究采用连续抽样法,抽取无子宫切除术或输卵管切除术(单侧或双侧)病史、无激素替代疗法或维生素D补充剂病史的绝经妇女。通过访谈和体检了解受试者的特征(年龄、绝经时间和体重指数)。采用免疫测定法测定 25(OH)D 水平,并进行 REMS 检查以评估 BMD。斯皮尔曼相关性检验用于评估血清维生素 D 水平与 BMD 之间的相关性。本研究共纳入 32 名更年期妇女,平均维生素 D 水平为(18.05±5.81)纳克/毫升,平均 BMD 水平为(-2.13±1.23)纳克/毫升。数据显示,更年期妇女的血清维生素 D 水平与 BMD 之间存在明显的正相关性(r=0.710;p=0.020)。这项研究强调,REMS 可以替代双能 X 射线吸收测定法(DXA)来评估绝经后妇女的 DMD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.90
自引率
0.00%
发文量
0
期刊最新文献
Determinants of mortality in relationship between clinical and laboratory characteristics with the outcomes of children with diphtheria: A cross-sectional study at a national hospital of Sumatra region in 2020–2023 Determinants of COVID-19 severity and mortality in children: A retrospective and multicenter cohort study in Medan, Indonesia Improving maternal health literacy among low-income pregnant women: A systematic review A fruit fly-based approach to unraveling enteropathy-causing pharmaceuticals. A potential treatment for erectile dysfunction: Effect of platelet-rich plasma administration on axon and collagen regeneration in cavernous nerve injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1