Test-Retest Reliability of Intraocular Pressure Measurements With Office-Based Versus Home-Based Rebound Tonometers.

IF 2 4区 医学 Q2 OPHTHALMOLOGY Journal of Glaucoma Pub Date : 2024-10-01 Epub Date: 2024-05-27 DOI:10.1097/IJG.0000000000002441
Tony Realini, Kevin Halenda, Joel Palko, Brian McMillan, Goundappa K Balasubramani
{"title":"Test-Retest Reliability of Intraocular Pressure Measurements With Office-Based Versus Home-Based Rebound Tonometers.","authors":"Tony Realini, Kevin Halenda, Joel Palko, Brian McMillan, Goundappa K Balasubramani","doi":"10.1097/IJG.0000000000002441","DOIUrl":null,"url":null,"abstract":"<p><strong>Prcis: </strong>Intraocular pressure (IOP) measurements obtained with the HOME2 rebound tonometer are interchangeable with measurements obtained using the office-based IC100 and IC200 rebound tonometers, making characterization of circadian IOP achievable with no inter-device sources of variability.</p><p><strong>Objective: </strong>To evaluate test-retest reliability between IOP measurements obtained with a home rebound tonometer operated by patients and those obtained with office rebound tonometers operated by experienced clinical staff.</p><p><strong>Methods: </strong>After training and practice with a home rebound tonometer (iCare HOME2) in a randomly selected eye, patients with established or suspected open angle glaucoma underwent IOP measurement in the fellow eye as follows in randomized order: 3 good quality measurements with the iCare IC100 operated by experienced clinical staff, 3 good quality measurements with the iCare IC200 operated by experienced clinical staff, and 3 good quality measurements with the HOME2 operated by the patient. The Shrout-Fleisch intraclass correlation coefficient (ICC; 2,1) was the measure of reliability utilized based on the model using 2-way random effects, absolute agreement, and single measurement.</p><p><strong>Results: </strong>Thirty eyes of 30 patients were evaluated. The Pearson correlation coefficient ( r ) for IOP measurements taken with the IC100 and HOME2 was 0.97, with the IC200 and HOME2 was 0.96, and with the IC100 and IC200 was 0.97. Test-retest reliability between HOME2 and IC100 (ICC: 0.90), HOME2 and IC200 (ICC: 0.92), and IC100 and IC200 (ICC: 0.94) all reflected excellent test-retest reliability.</p><p><strong>Conclusion: </strong>The test-retest reliability of IOP measurements taken by patients using the iCare HOME2 self-tonometer compared with IOP measurements taken by trained operators using the iCare IC100 and IC200 tonometers was uniformly excellent (ICCs all ≥0.9). These findings indicate that these three devices should be considered interchangeable for the clinical assessment of circadian IOP.</p>","PeriodicalId":15938,"journal":{"name":"Journal of Glaucoma","volume":" ","pages":"758-762"},"PeriodicalIF":2.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Glaucoma","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/IJG.0000000000002441","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Prcis: Intraocular pressure (IOP) measurements obtained with the HOME2 rebound tonometer are interchangeable with measurements obtained using the office-based IC100 and IC200 rebound tonometers, making characterization of circadian IOP achievable with no inter-device sources of variability.

Objective: To evaluate test-retest reliability between IOP measurements obtained with a home rebound tonometer operated by patients and those obtained with office rebound tonometers operated by experienced clinical staff.

Methods: After training and practice with a home rebound tonometer (iCare HOME2) in a randomly selected eye, patients with established or suspected open angle glaucoma underwent IOP measurement in the fellow eye as follows in randomized order: 3 good quality measurements with the iCare IC100 operated by experienced clinical staff, 3 good quality measurements with the iCare IC200 operated by experienced clinical staff, and 3 good quality measurements with the HOME2 operated by the patient. The Shrout-Fleisch intraclass correlation coefficient (ICC; 2,1) was the measure of reliability utilized based on the model using 2-way random effects, absolute agreement, and single measurement.

Results: Thirty eyes of 30 patients were evaluated. The Pearson correlation coefficient ( r ) for IOP measurements taken with the IC100 and HOME2 was 0.97, with the IC200 and HOME2 was 0.96, and with the IC100 and IC200 was 0.97. Test-retest reliability between HOME2 and IC100 (ICC: 0.90), HOME2 and IC200 (ICC: 0.92), and IC100 and IC200 (ICC: 0.94) all reflected excellent test-retest reliability.

Conclusion: The test-retest reliability of IOP measurements taken by patients using the iCare HOME2 self-tonometer compared with IOP measurements taken by trained operators using the iCare IC100 and IC200 tonometers was uniformly excellent (ICCs all ≥0.9). These findings indicate that these three devices should be considered interchangeable for the clinical assessment of circadian IOP.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
"使用办公室和家用回弹眼压计测量眼压的测试-重测可靠性"。
目的:评估患者使用家用回弹式眼压计和经验丰富的临床医务人员使用诊室回弹式眼压计测量眼压的重复测试可靠性:在随机选取的一只眼进行家用回弹式眼压计(iCare HOME2)的培训和练习后,已确诊或疑似开角型青光眼患者按以下随机顺序在另一只眼进行眼压测量:由经验丰富的临床医护人员操作 iCare IC100 进行 3 次优质测量,由经验丰富的临床医护人员操作 iCare IC200 进行 3 次优质测量,由受试者操作 HOME2 进行 3 次优质测量。根据使用双向随机效应、绝对一致和单次测量的模型,使用 Shrout-Fleisch 类内相关系数 ICC (2,1) 来衡量可靠性:对 30 名患者的 30 只眼睛进行了评估。使用 IC100 和 HOME2 测量眼压的皮尔逊相关系数(r)为 0.97,使用 IC200 和 HOME2 测量眼压的皮尔逊相关系数(r)为 0.96,使用 IC100 和 IC200 测量眼压的皮尔逊相关系数(r)为 0.97。HOME2和IC100(ICC为0.90)、HOME2和IC200(ICC为0.92)以及IC100和IC200(ICC为0.94)之间的重复测试可靠性都非常高:结论:与训练有素的操作人员使用 iCare IC100 和 IC200 眼压计进行的眼压测量相比,患者使用 iCare HOME2 自测眼压计进行的眼压测量的重复测试可靠性都非常好(ICC 均≥0.9)。这些结果表明,在昼夜节律性眼压的临床评估中,这三种设备可以互换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Glaucoma
Journal of Glaucoma 医学-眼科学
CiteScore
4.20
自引率
10.00%
发文量
330
审稿时长
4-8 weeks
期刊介绍: The Journal of Glaucoma is a peer reviewed journal addressing the spectrum of issues affecting definition, diagnosis, and management of glaucoma and providing a forum for lively and stimulating discussion of clinical, scientific, and socioeconomic factors affecting care of glaucoma patients.
期刊最新文献
Accuracy of the Heijl-Krakau Method During Blind-spot Stimulation with the Head Mounted Imo Perimeter in Patients with Glaucoma and Glaucoma Suspects. Evaluation of the Long-Term Effects of Selective Laser Trabeculoplasty on Patients with Primary Open Angle Glaucoma. Walking More Than 10,000 Steps Per Day May be Associated with Increased Optic Disc Vessel Density in Patients With Primary Open Angle Glaucoma. CYP3A4 Poor and Intermediate Metabolizers Have a Higher Rate of Steroid-Induced Intraocular Pressure Response. Evidence of Mitophagy in Lens Capsule Epithelial Cells of Patients With Pseudoexfoliation Syndrome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1