Micro-robotic percutaneous targeting of type II endoleaks in the angio-suite.

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal of Computer Assisted Radiology and Surgery Pub Date : 2024-08-01 Epub Date: 2024-05-29 DOI:10.1007/s11548-024-03195-y
Gerlig Widmann, Johannes Deeg, Andreas Frech, Josef Klocker, Gudrun Feuchtner, Martin Freund
{"title":"Micro-robotic percutaneous targeting of type II endoleaks in the angio-suite.","authors":"Gerlig Widmann, Johannes Deeg, Andreas Frech, Josef Klocker, Gudrun Feuchtner, Martin Freund","doi":"10.1007/s11548-024-03195-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Endovascular aneurysm repair has emerged as the standard therapy for abdominal aortic aneurysms. In 9-30% of cases, retrograde filling of the aneurysm sac through patent branch arteries may result in persistence of blood flow outside the graft and within the aneurysm sac. This condition is called an endoleak type II, which may be treated by catheter-based embolization in case of continued sac enlargement. If an endovascular access is not possible, percutaneous targeting of the perfused nidus remains the only option. However, this can be very challenging due to the difficult access and deep puncture with risk of organ perforation and bleeding. Innovative targeting techniques such as robotics may provide a promising option for safe and successful targeting.</p><p><strong>Methods: </strong>In nine consecutive patients, percutaneous embolization of type II endoleaks was performed using a table-mounted micro-robotic targeting platform. The needle path from the skin entry to the perfused nidus was planned based on the C-arm CT image data in the angio-suite. Entry point and path angle were aligned using the joystick-operated micro-robotic system under fluoroscopic control, and the coaxial needle was introduced until the target point within the perfused nidus was reached.</p><p><strong>Results: </strong>All punctures were successful, and there were no puncture-related complications. The pre-operative C-arm CT was executed in 11-15 s, and pathway planning required 2-3 min. The robotic setup and sterile draping were performed in 1-2 min, and the alignment to the surgical plan took no longer than 30 s.</p><p><strong>Conclusion: </strong>Due to the small size, the micro-robotic platform seamlessly integrated into the routine clinical workflow in the angio-suite. It offered significant benefits to the planning and safe execution of double-angulated deeply localized targets, such as type II endoleaks.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11329533/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03195-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/29 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Endovascular aneurysm repair has emerged as the standard therapy for abdominal aortic aneurysms. In 9-30% of cases, retrograde filling of the aneurysm sac through patent branch arteries may result in persistence of blood flow outside the graft and within the aneurysm sac. This condition is called an endoleak type II, which may be treated by catheter-based embolization in case of continued sac enlargement. If an endovascular access is not possible, percutaneous targeting of the perfused nidus remains the only option. However, this can be very challenging due to the difficult access and deep puncture with risk of organ perforation and bleeding. Innovative targeting techniques such as robotics may provide a promising option for safe and successful targeting.

Methods: In nine consecutive patients, percutaneous embolization of type II endoleaks was performed using a table-mounted micro-robotic targeting platform. The needle path from the skin entry to the perfused nidus was planned based on the C-arm CT image data in the angio-suite. Entry point and path angle were aligned using the joystick-operated micro-robotic system under fluoroscopic control, and the coaxial needle was introduced until the target point within the perfused nidus was reached.

Results: All punctures were successful, and there were no puncture-related complications. The pre-operative C-arm CT was executed in 11-15 s, and pathway planning required 2-3 min. The robotic setup and sterile draping were performed in 1-2 min, and the alignment to the surgical plan took no longer than 30 s.

Conclusion: Due to the small size, the micro-robotic platform seamlessly integrated into the routine clinical workflow in the angio-suite. It offered significant benefits to the planning and safe execution of double-angulated deeply localized targets, such as type II endoleaks.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用微型机器人经皮瞄准血管套房中的 II 型内漏。
目的:血管内动脉瘤修补术已成为腹主动脉瘤的标准疗法。在 9-30% 的病例中,动脉瘤囊通过通畅的分支动脉逆行充盈可能会导致移植物外和动脉瘤囊内的血流持续存在。这种情况被称为 II 型内漏,如果动脉瘤囊继续扩大,可通过导管栓塞治疗。如果无法进行血管内通路,经皮定位灌注瘤巢仍然是唯一的选择。然而,由于难以进入和穿刺过深,存在器官穿孔和出血的风险,这可能非常具有挑战性。创新的靶向技术(如机器人技术)可能会为安全、成功的靶向治疗提供一种有前途的选择:方法:使用台式微型机器人靶向平台对九名连续患者进行了经皮栓塞 II 型内膜漏。根据血管手术室的 C 臂 CT 图像数据,规划了从皮肤入口到灌注巢的进针路径。在透视控制下,使用操纵杆操作的微型机器人系统对准进针点和路径角度,然后将同轴针头引入,直至到达灌注髓核内的目标点:结果:所有穿刺均获成功,无穿刺相关并发症。术前 C 臂 CT 在 11-15 秒内完成,路径规划需要 2-3 分钟。机器人设置和无菌铺巾在 1-2 分钟内完成,对准手术计划的时间不超过 30 秒:结论:微型机器人平台体积小,可无缝融入血管手术室的常规临床工作流程。结论:由于微型机器人平台体积小,它能无缝地融入血管手术室的常规临床工作流程,为规划和安全实施双定位深部目标(如 II 型内漏)提供了显著优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
期刊最新文献
Optimization of percutaneous intervention robotic system for skin insertion force. Correction to: Micro-robotic percutaneous targeting of type II endoleaks in the angio-suite. Automated assessment of non-technical skills by heart-rate data. Artificial intelligence-based analysis of lower limb muscle mass and fatty degeneration in patients with knee osteoarthritis and its correlation with Knee Society Score. High-quality semi-supervised anomaly detection with generative adversarial networks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1