Aortic roadmapping during EVAR: a combined FEM-EM tracking feasibility study.

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal of Computer Assisted Radiology and Surgery Pub Date : 2024-11-01 Epub Date: 2024-06-02 DOI:10.1007/s11548-024-03187-y
Monica Emendi, Geir A Tangen, Pierluigi Di Giovanni, Håvard Ulsaker, Reidar Brekken, Frode Manstad-Hulaas, Victorien Prot, Aline Bel-Brunon, Karen H Støverud
{"title":"Aortic roadmapping during EVAR: a combined FEM-EM tracking feasibility study.","authors":"Monica Emendi, Geir A Tangen, Pierluigi Di Giovanni, Håvard Ulsaker, Reidar Brekken, Frode Manstad-Hulaas, Victorien Prot, Aline Bel-Brunon, Karen H Støverud","doi":"10.1007/s11548-024-03187-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Currently, the intra-operative visualization of vessels during endovascular aneurysm repair (EVAR) relies on contrast-based imaging modalities. Moreover, traditional image fusion techniques lack a continuous and automatic update of the vessel configuration, which changes due to the insertion of stiff guidewires. The purpose of this work is to develop and evaluate a novel approach to improve image fusion, that takes into account the deformations, combining electromagnetic (EM) tracking technology and finite element modeling (FEM).</p><p><strong>Methods: </strong>To assess whether EM tracking can improve the prediction of the numerical simulations, a patient-specific model of abdominal aorta was segmented and manufactured. A database of simulations with different insertion angles was created. Then, an ad hoc sensorized tool with three embedded EM sensors was designed, enabling tracking of the sensors' positions during the insertion phase. Finally, the corresponding cone beam computed tomography (CBCT) images were acquired and processed to obtain the ground truth aortic deformations of the manufactured model.</p><p><strong>Results: </strong>Among the simulations in the database, the one minimizing the in silico versus in vitro discrepancy in terms of sensors' positions gave the most accurate aortic displacement results.</p><p><strong>Conclusions: </strong>The proposed approach suggests that the EM tracking technology could be used not only to follow the tool, but also to minimize the error in the predicted aortic roadmap, thus paving the way for a safer EVAR navigation.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":"2239-2247"},"PeriodicalIF":2.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11541383/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03187-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Currently, the intra-operative visualization of vessels during endovascular aneurysm repair (EVAR) relies on contrast-based imaging modalities. Moreover, traditional image fusion techniques lack a continuous and automatic update of the vessel configuration, which changes due to the insertion of stiff guidewires. The purpose of this work is to develop and evaluate a novel approach to improve image fusion, that takes into account the deformations, combining electromagnetic (EM) tracking technology and finite element modeling (FEM).

Methods: To assess whether EM tracking can improve the prediction of the numerical simulations, a patient-specific model of abdominal aorta was segmented and manufactured. A database of simulations with different insertion angles was created. Then, an ad hoc sensorized tool with three embedded EM sensors was designed, enabling tracking of the sensors' positions during the insertion phase. Finally, the corresponding cone beam computed tomography (CBCT) images were acquired and processed to obtain the ground truth aortic deformations of the manufactured model.

Results: Among the simulations in the database, the one minimizing the in silico versus in vitro discrepancy in terms of sensors' positions gave the most accurate aortic displacement results.

Conclusions: The proposed approach suggests that the EM tracking technology could be used not only to follow the tool, but also to minimize the error in the predicted aortic roadmap, thus paving the way for a safer EVAR navigation.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EVAR 期间的主动脉路线图:FEM-EM 联合追踪可行性研究。
目的:目前,血管内动脉瘤修补术(EVAR)的术中血管可视化主要依赖于造影剂成像模式。此外,传统的图像融合技术缺乏对血管结构的连续自动更新,而血管结构会因插入坚硬的导丝而发生变化。这项工作的目的是结合电磁(EM)跟踪技术和有限元建模(FEM),开发并评估一种考虑到变形的新型图像融合方法:方法:为了评估电磁追踪是否能提高数值模拟的预测效果,我们分割并制作了一个患者专用的腹主动脉模型。建立了不同插入角度的模拟数据库。然后,设计了一个带有三个嵌入式电磁传感器的临时传感器化工具,以便在插入阶段跟踪传感器的位置。最后,采集并处理相应的锥形束计算机断层扫描(CBCT)图像,以获得制造模型的主动脉变形地面实况:结果:在数据库中的模拟结果中,传感器位置硅学与体外差异最小的模拟结果得到了最准确的主动脉位移结果:结论:所提出的方法表明,电磁跟踪技术不仅可用于跟踪工具,还可将主动脉路线图预测的误差降至最低,从而为更安全的 EVAR 导航铺平道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
期刊最新文献
Transferable situation recognition system for scenario-independent context-aware surgical assistance systems: a proof of concept. Correction to: Stereo reconstruction from microscopic images for computer-assisted ophthalmic surgery. Avoiding missed opportunities in AI for radiology. Hybrid registration of the fibula for electromagnetically navigated osteotomies in mandibular reconstructive surgery: a phantom study. Validity of a virtual reality-based straight coloanal anastomosis simulator.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1