Validity of Techniques to Evaluate Near Phoria

Jaime Bernal Escalante, M. Rosenfield, Elizabeth Casillas Casillas, Luis Fernando Barba Gallardo, Sergio Ramírez González
{"title":"Validity of Techniques to Evaluate Near Phoria","authors":"Jaime Bernal Escalante, M. Rosenfield, Elizabeth Casillas Casillas, Luis Fernando Barba Gallardo, Sergio Ramírez González","doi":"10.19052/sv.vol17.iss2.4","DOIUrl":null,"url":null,"abstract":"Background: While a number of previous studies have investigated the repeatability of techniques designed to measure heterophoria, there have been few studies of their validity. Accordingly, the present study examined the ability of 3 standard techniques; Von Graefe (VG), Maddox Rod (MR) and Modified Thorington (MT) tests to quantify a known change in heterophoria. Methods:The study was performed on 30 young subjects using each of the 3 procedures listed above. Near (40 cm) heterophoria was quantified both without and with an additional base-out prism. Five possible values were available, namely 2, 4, 6, 8 and 9Δ. After a period of 24 hours, the heterophoria measurement was repeated using the same technique with one of these prisms added to the refractive correction. Results:The mean heterophoria value measured before the introduction of prism using the VG procedure was significantly more exophoric than the findings obtained using the other 2 techniques (p = 0.035). No significant difference was observed between the measured and predicted change in heterophoria following the introduction of the prism for the VG and MT procedures, but a significant difference was found with the MR technique (p0.001). Conclusions:The ability to measure a known change in oculomotor deviation was significantly poorer with the MR technique, when compared with the VG and MT procedures. Given that the mean pre-prism measurement was significantly more exophoric when using the VG procedure, we recommend that MT be adopted as the technique of choice for the subjective measurement of oculomotor deviations in the clinical setting","PeriodicalId":505407,"journal":{"name":"Ciencia y Tecnología para la Salud Visual y Ocular","volume":" 69","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ciencia y Tecnología para la Salud Visual y Ocular","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19052/sv.vol17.iss2.4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: While a number of previous studies have investigated the repeatability of techniques designed to measure heterophoria, there have been few studies of their validity. Accordingly, the present study examined the ability of 3 standard techniques; Von Graefe (VG), Maddox Rod (MR) and Modified Thorington (MT) tests to quantify a known change in heterophoria. Methods:The study was performed on 30 young subjects using each of the 3 procedures listed above. Near (40 cm) heterophoria was quantified both without and with an additional base-out prism. Five possible values were available, namely 2, 4, 6, 8 and 9Δ. After a period of 24 hours, the heterophoria measurement was repeated using the same technique with one of these prisms added to the refractive correction. Results:The mean heterophoria value measured before the introduction of prism using the VG procedure was significantly more exophoric than the findings obtained using the other 2 techniques (p = 0.035). No significant difference was observed between the measured and predicted change in heterophoria following the introduction of the prism for the VG and MT procedures, but a significant difference was found with the MR technique (p0.001). Conclusions:The ability to measure a known change in oculomotor deviation was significantly poorer with the MR technique, when compared with the VG and MT procedures. Given that the mean pre-prism measurement was significantly more exophoric when using the VG procedure, we recommend that MT be adopted as the technique of choice for the subjective measurement of oculomotor deviations in the clinical setting
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
近齿畸变评估技术的有效性
背景:虽然以前的许多研究都对测量异相的技术的可重复性进行了调查,但对其有效性的研究却很少。因此,本研究考察了三种标准技术的能力:冯-格拉夫(VG)、马多克斯棒(MR)和改良索林顿(MT)测试,以量化已知的异视变化。方法:该研究对 30 名年轻受试者分别使用上述 3 种方法进行了测试。对近距离(40 厘米)异视角进行量化,包括不使用和使用额外的基底棱镜。有五个可能的值,即 2、4、6、8 和 9Δ。24 小时后,使用同样的技术,在屈光校正时添加其中一个棱镜,重复异视测量。结果:使用 VG 方法测量的引入棱镜前的平均异视值明显高于使用其他两种方法得出的结果(p = 0.035)。在 VG 和 MT 方法中,引入棱镜后异视的测量值和预测值之间没有明显差异,但在 MR 技术中发现了明显差异(p0.001)。结论:与 VG 和 MT 方法相比,MR 方法测量已知眼球运动偏差变化的能力明显较差。鉴于使用 VG 程序时棱镜前测量结果的平均值明显偏高,我们建议在临床环境中采用 MT 作为主观测量眼球运动偏差的首选技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Long-term evolution of signs and symptoms in contact lens wearers ¿Azitromicina tópica al 1,5 % para el tratamiento de la disfunción de las glándulas de Meibomio? Prevalencia de astenopia en niños escolares de 6 a 17 años, por el uso de pantallas digitales durante la pandemia por covid-19 (2020-2022): revisión sistemática Impacto de la pandemia por covid-19 en la decisión de los pacientes sometidos a cirugía refractiva en una institución privada en Bogotá, Colombia Posible uso de la leche materna como agente profiláctico y terapéutico en conjuntivitis en bebés menores de 6 meses de edad
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1