{"title":"The effectiveness of the 0.19 mg fluocinolone acetonide implant in treating non-infectious posterior uveitis: a real-world experience.","authors":"Igor Kozak, Avinash Gurbaxani, Maya Pandova","doi":"10.1186/s12348-024-00409-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The 0.19 mg fluocinolone acetonide (FAc) implant (ILUVIEN) has been approved for prevention of relapse in recurrent non-infectious uveitis affecting the posterior segment of the eye (NIU-PS). There is little data assessing the long-term efficacy and safety of the FAc implant in this indication. Therefore, we conducted a retrospective interventional case review of 18 eyes from 13 patients with NIU-PS treated with the FAc implant at three ophthalmology departments in the Middle East between 2018 and 2021.</p><p><strong>Main text: </strong>Baseline patient characteristics, including best-corrected visual acuity (BCVA), central retinal thickness (CRT) and intraocular pressure (IOP), were collected at the time of FAc implant administration and at 1-3 months, 6 months and every six months thereafter. The mean time of follow-up was 29.7 ± 14.6 (mean ± SD) months. Over the follow-up, the BCVA significantly increased from month 1 (P = 0.002) until month 36 (P = 0.024) and remained improving throughout the follow-up period (P = 0.004). The CRT significantly decreased from month 1 (P = 0.008) until month 12 (P = 0.003) and was persistently lower during the follow-up period (P = 0.022). Significant improvements in anterior chamber cells (P = 0.004) and vitritis scores (P = 0.001) were observed by Month 6. Similarly, at Month 12, significant improvements were noted in both parameters as well (anterior chamber cells: P = 0.012; vitritis scores: P = 0.004). Mean IOP remained relatively stable throughout (P = 0.205) the follow-up.</p><p><strong>Conclusions: </strong>Our results suggest improvements and long-term maintenance in functional and anatomical outcomes with FAc implant with a manageable safety profile in a real-world clinical setting in patients with NIU-PS.</p>","PeriodicalId":16600,"journal":{"name":"Journal of Ophthalmic Inflammation and Infection","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11150361/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic Inflammation and Infection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s12348-024-00409-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The 0.19 mg fluocinolone acetonide (FAc) implant (ILUVIEN) has been approved for prevention of relapse in recurrent non-infectious uveitis affecting the posterior segment of the eye (NIU-PS). There is little data assessing the long-term efficacy and safety of the FAc implant in this indication. Therefore, we conducted a retrospective interventional case review of 18 eyes from 13 patients with NIU-PS treated with the FAc implant at three ophthalmology departments in the Middle East between 2018 and 2021.
Main text: Baseline patient characteristics, including best-corrected visual acuity (BCVA), central retinal thickness (CRT) and intraocular pressure (IOP), were collected at the time of FAc implant administration and at 1-3 months, 6 months and every six months thereafter. The mean time of follow-up was 29.7 ± 14.6 (mean ± SD) months. Over the follow-up, the BCVA significantly increased from month 1 (P = 0.002) until month 36 (P = 0.024) and remained improving throughout the follow-up period (P = 0.004). The CRT significantly decreased from month 1 (P = 0.008) until month 12 (P = 0.003) and was persistently lower during the follow-up period (P = 0.022). Significant improvements in anterior chamber cells (P = 0.004) and vitritis scores (P = 0.001) were observed by Month 6. Similarly, at Month 12, significant improvements were noted in both parameters as well (anterior chamber cells: P = 0.012; vitritis scores: P = 0.004). Mean IOP remained relatively stable throughout (P = 0.205) the follow-up.
Conclusions: Our results suggest improvements and long-term maintenance in functional and anatomical outcomes with FAc implant with a manageable safety profile in a real-world clinical setting in patients with NIU-PS.