{"title":"Distal mechanical thrombectomy using beveled tip aspiration zoom catheters: A preliminary study.","authors":"Jonathan Dallas, Vincent N Nguyen, Joel M Sequeiros, Shelby Graham, Jared Burns-Martin, Nitin Goyal, Kasra Khatibi","doi":"10.1177/15910199241258289","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Distal medium vessel occlusion (DVO) thrombectomy has been shown to be efficacious with safety profiles comparable to large vessel occlusion (LVO) thrombectomy. A novel, highly-trackable, bevel-tipped Zoom 35 catheter can be used as an aspiration catheter for DVO thrombectomy.</p><p><strong>Methods: </strong>This is a retrospective, single-arm, multi-institutional observational study evaluating the efficacy and safety of aspiration thrombectomy for DVO using the Zoom 35 catheter. Patient demographics, presenting and discharge NIHSS, primary and rescue thrombectomy, site of occlusion, TICI score, and intracranial hemorrhage were chart abstracted. Descriptive statistics were used to evaluate the efficacy and safety of thrombectomy.</p><p><strong>Results: </strong>Fourteen patients (mean age 66.64 ± 13.75 years) were included. The mean NIHSS at presentation was 10.79 ± 5.48, and the mean ASPECTS was 9.00 ± 0.89. Nine patients (64.3%) received tPA. Primary occlusion location was M3 in nine cases (64.3%), M2/M3 junction in two cases (14.3%), A2 in one case (7.1%), A3 in one case (7.1%), and P1 in one case (7.1%). TICI scores were 3 in seven cases (50.0%), 2C in three cases (21.4%), and 2B in four cases (28.6%). There was one postoperative SAH (7.1%) and one asymptomatic ICH (7.1%). Mean discharge NIHSS was 3.38 ± 4.44, with a mean decrease of 7.31 from presentation (p < 0.0001, t-test).</p><p><strong>Conclusion: </strong>Zoom 35 beveled-tip aspiration microcatheters are highly trackable and associated with improved radiographic and clinical outcomes for the treatment of DVO with a good safety profile.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199241258289","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Distal medium vessel occlusion (DVO) thrombectomy has been shown to be efficacious with safety profiles comparable to large vessel occlusion (LVO) thrombectomy. A novel, highly-trackable, bevel-tipped Zoom 35 catheter can be used as an aspiration catheter for DVO thrombectomy.

Methods: This is a retrospective, single-arm, multi-institutional observational study evaluating the efficacy and safety of aspiration thrombectomy for DVO using the Zoom 35 catheter. Patient demographics, presenting and discharge NIHSS, primary and rescue thrombectomy, site of occlusion, TICI score, and intracranial hemorrhage were chart abstracted. Descriptive statistics were used to evaluate the efficacy and safety of thrombectomy.

Results: Fourteen patients (mean age 66.64 ± 13.75 years) were included. The mean NIHSS at presentation was 10.79 ± 5.48, and the mean ASPECTS was 9.00 ± 0.89. Nine patients (64.3%) received tPA. Primary occlusion location was M3 in nine cases (64.3%), M2/M3 junction in two cases (14.3%), A2 in one case (7.1%), A3 in one case (7.1%), and P1 in one case (7.1%). TICI scores were 3 in seven cases (50.0%), 2C in three cases (21.4%), and 2B in four cases (28.6%). There was one postoperative SAH (7.1%) and one asymptomatic ICH (7.1%). Mean discharge NIHSS was 3.38 ± 4.44, with a mean decrease of 7.31 from presentation (p < 0.0001, t-test).

Conclusion: Zoom 35 beveled-tip aspiration microcatheters are highly trackable and associated with improved radiographic and clinical outcomes for the treatment of DVO with a good safety profile.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用斜面尖端抽吸变焦导管进行远端机械血栓切除术:初步研究。
简介:远端中血管闭塞(DVO)血栓切除术已被证明疗效显著,安全性与大血管闭塞(LVO)血栓切除术相当。一种新颖、可高度追踪、斜面尖端的 Zoom 35 导管可用作 DVO 血栓切除术的抽吸导管:这是一项回顾性、单臂、多机构观察研究,评估使用 Zoom 35 导管对 DVO 进行血栓抽吸切除术的有效性和安全性。研究人员对患者的人口统计学特征、发病和出院时的 NIHSS、主要血栓切除术和抢救性血栓切除术、闭塞部位、TICI 评分和颅内出血情况进行了病历摘录。使用描述性统计来评估血栓切除术的有效性和安全性:共纳入 14 名患者(平均年龄为 66.64 ± 13.75 岁)。发病时 NIHSS 平均值为 10.79 ± 5.48,ASPECTS 平均值为 9.00 ± 0.89。九名患者(64.3%)接受了 tPA 治疗。9例患者(64.3%)的原发闭塞位置为M3,2例患者(14.3%)的原发闭塞位置为M2/M3交界处,1例患者(7.1%)的原发闭塞位置为A2,1例患者(7.1%)的原发闭塞位置为A3,1例患者(7.1%)的原发闭塞位置为P1。TICI 评分为 3 分的有 7 例(50.0%),2C 分的有 3 例(21.4%),2B 分的有 4 例(28.6%)。术后 SAH 1 例(7.1%),无症状 ICH 1 例(7.1%)。出院时 NIHSS 平均值为 3.38 ± 4.44,与就诊时相比平均下降了 7.31(p 结论:术后 NIHSS 平均值为 3.38 ± 4.44,与就诊时相比平均下降了 7.31:Zoom 35 斜面尖端抽吸微导管具有很高的可追踪性,在治疗 DVO 时可改善影像学和临床疗效,且安全性良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Interventional Neuroradiology
Interventional Neuroradiology CLINICAL NEUROLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
3.60
自引率
11.80%
发文量
192
审稿时长
6-12 weeks
期刊介绍: Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...
期刊最新文献
Emergent endovascular treatment versus medical treatment for acute large vessel occlusions with nondisabling symptoms. Performance assessment of the Surpass Evolve flow diverter for the treatment of intracranial aneurysms: A systematic review and meta-analysis. Safety and efficacy of coated flow diverters in the treatment of cerebral aneurysms during single antiplatelet therapy: A multicenter study. Silk vista baby flow diversion beyond the circle of Willis: A single-center experience with long-term outcomes. WFITN 2024 - 17th Congress of World Federation of Interventional and Therapeutic Neuroradiology - October 6-10, 2024 - New York, USA.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1