Perforation of the Heart During Elective Removal of an Inferior Vena Cava Filter.

IF 1 4区 医学 Q3 MEDICINE, LEGAL American Journal of Forensic Medicine and Pathology Pub Date : 2024-12-01 Epub Date: 2024-05-23 DOI:10.1097/PAF.0000000000000947
Sapna P Desai, Christine Z Yu, Frank Evangelista, James R Gill
{"title":"Perforation of the Heart During Elective Removal of an Inferior Vena Cava Filter.","authors":"Sapna P Desai, Christine Z Yu, Frank Evangelista, James R Gill","doi":"10.1097/PAF.0000000000000947","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>A common treatment for venous thromboembolic disease in patients with contraindications to anticoagulation includes placement of an inferior vena cava (IVC) filter. Temporary filters are available to avoid the risk of long-term permanent placement. A woman in her 60s with a history of uterine serous carcinoma presented to the emergency department with cardiac arrest following elective attempted IVC filter removal. Three months prior, a temporary filter was placed because anticoagulation medication was stopped in preparation for a hysterectomy. During the IVC retrieval procedure, which was performed using an intravascular approach from the right jugular vein, the filter was tilted, requiring the use of a different retrieval sheath. During catheter reentry, the patient complained of discomfort in the chest and neck, after which she became hypotensive, lost consciousness, and died. Autopsy revealed 2 cardiac perforations, one in each ventricle. Approximately 600 mL of liquid and clotted blood was within the tense pericardial sac. An IVC filter was found in place, with no adjacent hemorrhage.To our knowledge, this is the first reported fatality due to cardiac perforation by an access sheath during intravascular removal of an IVC filter. This instance also documents the time course of the cardiac perforations to the resultant loss of consciousness.</p>","PeriodicalId":55535,"journal":{"name":"American Journal of Forensic Medicine and Pathology","volume":" ","pages":"347-351"},"PeriodicalIF":1.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Forensic Medicine and Pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PAF.0000000000000947","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/23 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"MEDICINE, LEGAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract: A common treatment for venous thromboembolic disease in patients with contraindications to anticoagulation includes placement of an inferior vena cava (IVC) filter. Temporary filters are available to avoid the risk of long-term permanent placement. A woman in her 60s with a history of uterine serous carcinoma presented to the emergency department with cardiac arrest following elective attempted IVC filter removal. Three months prior, a temporary filter was placed because anticoagulation medication was stopped in preparation for a hysterectomy. During the IVC retrieval procedure, which was performed using an intravascular approach from the right jugular vein, the filter was tilted, requiring the use of a different retrieval sheath. During catheter reentry, the patient complained of discomfort in the chest and neck, after which she became hypotensive, lost consciousness, and died. Autopsy revealed 2 cardiac perforations, one in each ventricle. Approximately 600 mL of liquid and clotted blood was within the tense pericardial sac. An IVC filter was found in place, with no adjacent hemorrhage.To our knowledge, this is the first reported fatality due to cardiac perforation by an access sheath during intravascular removal of an IVC filter. This instance also documents the time course of the cardiac perforations to the resultant loss of consciousness.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在择期取出下腔静脉过滤器时发生心脏穿孔。
摘要:对于有抗凝禁忌症的患者,静脉血栓栓塞性疾病的常见治疗方法包括放置下腔静脉(IVC)滤器。为了避免长期永久置入的风险,可以使用临时过滤器。一名 60 多岁的女性患者曾患子宫浆液性癌,在急诊科就诊时,因试图取出 IVC 过滤器而心跳骤停。三个月前,由于准备进行子宫切除术而停用了抗凝药物,因此放置了一个临时过滤器。在使用右颈静脉血管内入路进行的 IVC 取出手术中,过滤器发生倾斜,需要使用不同的取出鞘。在导管再入过程中,患者主诉胸部和颈部不适,随后出现低血压、失去知觉并死亡。尸检发现两处心脏穿孔,每个心室一处。紧张的心包囊内有大约 600 毫升液体和凝固的血液。据我们所知,这是首例在血管内移除 IVC 过滤器时因入路鞘造成心脏穿孔而导致死亡的报道。据我们所知,这是第一例在血管内移除 IVC 过滤器时因入路鞘造成心脏穿孔而死亡的病例,该病例还记录了从心脏穿孔到意识丧失的时间过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
103
审稿时长
4-8 weeks
期刊介绍: Drawing on the expertise of leading forensic pathologists, lawyers, and criminologists, The American Journal of Forensic Medicine and Pathology presents up-to-date coverage of forensic medical practices worldwide. Each issue of the journal features original articles on new examination and documentation procedures. While most articles are available as web based articles, PDF and in ePub reader format, some earlier articles do not have PDFs available. If you would like to view an article in the ePub format, you will need to download an ePub reader to view this file, a number of which are available for free online.
期刊最新文献
Incidental Finding of an Early-Stage Intrauterine Pregnancy at Autopsy. Fatal Tension Gastrothorax: Two Case Reports. Illustrated Forensic Pathology: Necklacing. Fat Embolism Fatalities Following Liposuction/Injection in Los Angeles County (2010-2018). Human Herpesvirus 6 Encephalitis: An Autopsy Case and Literature Review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1