Usefulness of bicarbonate-based Impella purge solution in a patient with heparin-induced thrombocytopenia: the first case report of long-term management in Japan.

IF 1.1 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Artificial Organs Pub Date : 2024-06-06 DOI:10.1007/s10047-024-01452-0
Shin Nagai, Hiroaki Hiraiwa, Ryota Ito, Yuichiro Koyama, Kiyota Kondo, Shingo Kazama, Toru Kondo, Ryota Morimoto, Takahiro Okumura, Hideki Ito, Tomo Yoshizumi, Masato Mutsuga, Toyoaki Murohara
{"title":"Usefulness of bicarbonate-based Impella purge solution in a patient with heparin-induced thrombocytopenia: the first case report of long-term management in Japan.","authors":"Shin Nagai, Hiroaki Hiraiwa, Ryota Ito, Yuichiro Koyama, Kiyota Kondo, Shingo Kazama, Toru Kondo, Ryota Morimoto, Takahiro Okumura, Hideki Ito, Tomo Yoshizumi, Masato Mutsuga, Toyoaki Murohara","doi":"10.1007/s10047-024-01452-0","DOIUrl":null,"url":null,"abstract":"<p><p>Percutaneous mechanical circulatory support utilizing micro-axial flow pumps, such as the Impella group of devices, has become a life-saving technique in the treatment of refractory cardiogenic shock, with ever-increasing success rates. A 30-year-old man presented with acute decompensated heart failure and a severely reduced left ventricular ejection fraction (17%). Despite initial treatment with inotropic drugs and intra-aortic balloon pump support, his hemodynamic status remained unstable. Transition to Impella CP mechanical circulatory support was made on day 6 owing to persistently low systolic blood pressure. A significant decline in platelet count prompted suspicion of heparin-induced thrombocytopenia (HIT), later confirmed by positive platelet-activated anti-platelet factor 4/heparin antibody and a 4Ts score of 6 points. Argatroban was initially used as the purge solution, but owing to complications, a switch to Impella 5.0 and a bicarbonate-based purge solution (BBPS) was performed. Despite additional veno-arterial extracorporeal membrane oxygenation support on day 24, the patient, aiming for ventricular assist device treatment and heart transplantation, died from infection and multiple organ failure. Remarkably, the Impella CP continued functioning normally until the patient's demise, indicating stable Impella pump performance using BBPS. This case highlights the usefulness of BBPS as an alternative to conventional Impella heparin purge solution when HIT occurs.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-024-01452-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Percutaneous mechanical circulatory support utilizing micro-axial flow pumps, such as the Impella group of devices, has become a life-saving technique in the treatment of refractory cardiogenic shock, with ever-increasing success rates. A 30-year-old man presented with acute decompensated heart failure and a severely reduced left ventricular ejection fraction (17%). Despite initial treatment with inotropic drugs and intra-aortic balloon pump support, his hemodynamic status remained unstable. Transition to Impella CP mechanical circulatory support was made on day 6 owing to persistently low systolic blood pressure. A significant decline in platelet count prompted suspicion of heparin-induced thrombocytopenia (HIT), later confirmed by positive platelet-activated anti-platelet factor 4/heparin antibody and a 4Ts score of 6 points. Argatroban was initially used as the purge solution, but owing to complications, a switch to Impella 5.0 and a bicarbonate-based purge solution (BBPS) was performed. Despite additional veno-arterial extracorporeal membrane oxygenation support on day 24, the patient, aiming for ventricular assist device treatment and heart transplantation, died from infection and multiple organ failure. Remarkably, the Impella CP continued functioning normally until the patient's demise, indicating stable Impella pump performance using BBPS. This case highlights the usefulness of BBPS as an alternative to conventional Impella heparin purge solution when HIT occurs.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
以碳酸氢盐为基础的 Impella 冲洗液在肝素诱发血小板减少症患者中的应用:日本首例长期管理病例报告。
利用微轴流泵(如 Impella 设备系列)进行经皮机械循环支持已成为治疗难治性心源性休克的救命技术,其成功率也在不断提高。一名 30 岁男子出现急性失代偿性心力衰竭,左心室射血分数严重下降(17%)。尽管最初使用了肌力药物和主动脉内球囊泵支持治疗,但他的血液动力学状态仍不稳定。由于收缩压持续偏低,第 6 天转用 Impella CP 机械循环支持。血小板计数明显下降,让人怀疑是肝素诱导的血小板减少症(HIT),后经血小板活化抗血小板因子 4/肝素抗体阳性和 4Ts 评分 6 分证实。最初使用阿加曲班作为净化溶液,但由于并发症,改用 Impella 5.0 和基于碳酸氢盐的净化溶液 (BBPS)。尽管在第24天又进行了静脉-动脉体外膜氧合支持,但这位以心室辅助装置治疗和心脏移植为目标的患者还是死于感染和多器官衰竭。值得注意的是,Impella CP 在患者去世前一直正常运行,这表明使用 BBPS 的 Impella 泵性能稳定。该病例突出表明,当发生 HIT 时,BBPS 可以替代传统的 Impella 肝素清洗液。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
期刊最新文献
Exploring the role of plasmapheresis prior to thyroidectomy in managing thyrotoxicosis: a comprehensive scoping review. A compact machine perfusion device for whole blood perfusion in isolated rat liver. Advanced roll porous scaffold 3D bioprinting technology. Impact of the spleen size on short-term prognosis in patients with cardiogenic shock receiving Impella-incorporated temporary mechanical circulatory support Axial-flow polymer bridge pump with hydrodynamic bearings
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1