Intelligent Miniplatform for On-Site Monitoring of Water Samples and Pharmaceutical Production of Ointments Based on Betamethasone and Gentamicin as Active Pharmaceutical Ingredients
Bianca-Maria Ţuchiu, Raluca‐Ioana Stefan‐van Staden, J. V. van Staden
{"title":"Intelligent Miniplatform for On-Site Monitoring of Water Samples and Pharmaceutical Production of Ointments Based on Betamethasone and Gentamicin as Active Pharmaceutical Ingredients","authors":"Bianca-Maria Ţuchiu, Raluca‐Ioana Stefan‐van Staden, J. V. van Staden","doi":"10.1149/1945-7111/ad537e","DOIUrl":null,"url":null,"abstract":"\n Betamethasone and gentamicin combination is commonly used in various dermatological conditions. In addition to the topical dosage forms in which this combination can be found, it can also accidentally end up in surface water following removal by washing. For this reason, a disposable miniplatform was constructed by modifying a boron-doped diamond screen printed electrode with calix[4]arene-25,26,27,28-tetrol. Wide linear ranges and low limits of quantification (LOQ) were achieved for both analytes: 1.0 × 10−16 − 1.0 × 10−2 mol L‒1 and a LOQ of 1.0 × 10−16 mol L‒1 for betamethasone, and 1.0 × 10−17 − 1.0 × 10−2 mol L‒1 and a LOQ of 1.0 × 10−17 mol L‒1 for gentamicin. The platform was tested on real samples, obtaining recovery values close to 100% and relative standard deviation values below 0.03%. Additionally, a comparison is provided between the proposed approach and existing electrochemical sensors to emphasize the achieved results.","PeriodicalId":509718,"journal":{"name":"Journal of The Electrochemical Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Electrochemical Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/1945-7111/ad537e","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Betamethasone and gentamicin combination is commonly used in various dermatological conditions. In addition to the topical dosage forms in which this combination can be found, it can also accidentally end up in surface water following removal by washing. For this reason, a disposable miniplatform was constructed by modifying a boron-doped diamond screen printed electrode with calix[4]arene-25,26,27,28-tetrol. Wide linear ranges and low limits of quantification (LOQ) were achieved for both analytes: 1.0 × 10−16 − 1.0 × 10−2 mol L‒1 and a LOQ of 1.0 × 10−16 mol L‒1 for betamethasone, and 1.0 × 10−17 − 1.0 × 10−2 mol L‒1 and a LOQ of 1.0 × 10−17 mol L‒1 for gentamicin. The platform was tested on real samples, obtaining recovery values close to 100% and relative standard deviation values below 0.03%. Additionally, a comparison is provided between the proposed approach and existing electrochemical sensors to emphasize the achieved results.