Clinical Outcomes of a Toric Enhanced Depth-of-Focus Intraocular Lens Based on the Combination of 4th- and 6th-Order Spherical Aberration.

IF 3 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2024-05-01 DOI:10.3928/1081597X-20240501-02
Ramón Ruiz-Mesa, Gracia Castro de Luna, María Ruiz-Santos, Ana Jiménez-Nieto, Pedro Tañá-Rivero
{"title":"Clinical Outcomes of a Toric Enhanced Depth-of-Focus Intraocular Lens Based on the Combination of 4th- and 6th-Order Spherical Aberration.","authors":"Ramón Ruiz-Mesa, Gracia Castro de Luna, María Ruiz-Santos, Ana Jiménez-Nieto, Pedro Tañá-Rivero","doi":"10.3928/1081597X-20240501-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery.</p><p><strong>Methods: </strong>A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire.</p><p><strong>Results: </strong>The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers.</p><p><strong>Conclusions: </strong>Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. <b>[<i>J Refract Surg</i>. 2024;40(6):e398-e406.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 6","pages":"e398-e406"},"PeriodicalIF":3.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240501-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery.

Methods: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire.

Results: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers.

Conclusions: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于第 4 阶和第 6 阶球面像差组合的散光增强焦距眼内透镜的临床效果。
目的:评估白内障手术后植入散光延焦深度(EDOF)眼内人工晶体(IOL)的患者的视觉和屈光效果:共对 44 只植入 EDOF LuxSmart 散光人工晶体的眼睛进行了术后 4 至 6 个月的评估。评估的主要结果包括屈光不正、旋转稳定性、远、中、近视力、散焦曲线、光和中近对比敏感度、波前像差、调制传递函数以及 Catquest-9SF 问卷:术后球面等效度数和圆柱度数的平均值分别为 -0.02 ± 0.26 和 -0.17 ± 0.29 斜度(D)。90.45%和100%的眼睛术后球面等值分别在±0.50和±1.00 D以内(屈光圆柱度分别为93.18%和100%)。平均旋转稳定性为 0.61 ± 1.61 度。双眼矫正远视力(CDVA)、矫正中视力(CDIVA)和矫正近视力(CDNVA)的平均值分别为 -0.02 ± 0.06、0.07 ± 0.08 和 0.26 ± 0.09 logMAR。95.45%的患者 CDVA 为 20/25 或更佳,72.73%的患者 CDIVA 为 20/25 或更佳,72.73%的患者 CDNVA 为 20/40 或更佳。散焦曲线显示远距离和中距离视力良好。对比敏感度和光学质量结果良好,高阶像差、球差和彗差的平均值分别为 0.161 ± 0.155、-0.019 ± 0.048 和 0.080 ± 0.065 µm。90.9%的患者对术后的视力表示比较满意或非常满意,77.7%的患者表示在阅读报纸上的文字时没有任何困难:结论:植入散光纯屈光EDOF技术人工晶体可在不同距离上提供良好的屈光、光学和视觉质量,患者满意度很高。[J Refract Surg. 2024;40(6):e398-e406]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
From Inside. Effect of Anterior Capsule Polishing on the Capsule-IOL Complex in Patients With Normal Axial Length: A Prospective Randomized Controlled Trial. An Analysis of the Influence of Flap Margin Space on Corneal Nerve Regeneration After Femtosecond Laser-Assisted LASIK. Direct Neodymium:YAG Laser Over the Occluded Phakic Implantable Collamer Lens Port to Manage Pupillary Block. Effect of Total Laser Fluence on Early and Mid-term Visual and Optical Quality Outcomes After Lenticule Extraction With the SCHWIND ATOS: A Single-Center Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1