Superiority of 3D planimetry over pressure half-time method for the assessment of mitral valve area after percutaneous edge-to-edge mitral repair.

IF 7.2 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Revista española de cardiología (English ed.) Pub Date : 2024-06-04 DOI:10.1016/j.rec.2024.03.017
Miriam Estrada Ledesma, Diana Bastidas Plaza, Eduardo Pozo Osinalde, Pedro Marcos-Alberca, Carmen Olmos Blanco, Patricia Mahía Casado, María Luaces, José Juan Gómez de Diego, Luis Nombela-Franco, Pilar Jiménez-Quevedo, Gabriela Tirado, Luis Collado Yurrita, Antonio Fernández-Ortiz, Julián Villacastín, José Alberto de Agustín
{"title":"Superiority of 3D planimetry over pressure half-time method for the assessment of mitral valve area after percutaneous edge-to-edge mitral repair.","authors":"Miriam Estrada Ledesma, Diana Bastidas Plaza, Eduardo Pozo Osinalde, Pedro Marcos-Alberca, Carmen Olmos Blanco, Patricia Mahía Casado, María Luaces, José Juan Gómez de Diego, Luis Nombela-Franco, Pilar Jiménez-Quevedo, Gabriela Tirado, Luis Collado Yurrita, Antonio Fernández-Ortiz, Julián Villacastín, José Alberto de Agustín","doi":"10.1016/j.rec.2024.03.017","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction and objectives: </strong>There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient.</p><p><strong>Methods: </strong>A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient.</p><p><strong>Results: </strong>We analyzed data from 167 patients. The mean age was 76±10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89±0.60 cm<sup>2</sup> using pressure half-time (PHT), 2.87±0.83 cm<sup>2</sup> using 3D planimetry, and the mean gradient was 3±1.19mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r=0.46, P<.001) than MVA obtained by PHT (r=0.19, P=.048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively).</p><p><strong>Conclusions: </strong>Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.</p>","PeriodicalId":38430,"journal":{"name":"Revista española de cardiología (English ed.)","volume":null,"pages":null},"PeriodicalIF":7.2000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista española de cardiología (English ed.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.rec.2024.03.017","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient.

Methods: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient.

Results: We analyzed data from 167 patients. The mean age was 76±10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89±0.60 cm2 using pressure half-time (PHT), 2.87±0.83 cm2 using 3D planimetry, and the mean gradient was 3±1.19mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r=0.46, P<.001) than MVA obtained by PHT (r=0.19, P=.048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively).

Conclusions: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在经皮二尖瓣边缘对边缘修补术后评估二尖瓣面积时,三维平面测量法优于压力半衰期法。
简介和目的:关于经皮二尖瓣边缘对边缘修补术后测量二尖瓣面积(MVA)的最准确方法,目前证据有限。我们的目的是评估这种情况下的最佳方法及其与平均二尖瓣跨瓣梯度的相关性:我们对接受经皮二尖瓣修复术的患者进行了登记,分析了测量 MVA 的不同方法及其与平均阶差的相关性:我们分析了 167 名患者的数据。平均年龄为 76 ± 10.3 岁,54% 为男性,46% 为女性。病因为退行性病变的占 45%,功能性病变的占 39%,混合性病变的占 16%。使用压力半定时法(PHT)测量的夹板后MVA为(1.89 ± 0.60)平方厘米,使用三维平面测量法测量的MVA为(2.87 ± 0.83)平方厘米,平均梯度为(3 ± 1.19)毫米汞柱。使用三维平面测量法得出的 MVA 与平均阶差的相关性更强(r = 0.46,P 结论:使用三维平面测量法得出的 MVA 与平均阶差的相关性更强:我们的研究表明,与使用经食道三维平面测量法直接测量相比,PHT 法明显低估了植入夹子后的 MVA。后者与植入后梯度的相关性更好,观察者之间的变异性也更小。这些结果表明,三维平面测量法是评估夹片植入后二尖瓣狭窄的更合适的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.70
自引率
0.00%
发文量
219
期刊最新文献
Impact of left ventricular unloading on postheart transplantation outcomes in patients bridged with VA-ECMO. David after Ross: a possible option before Bentall? Prognostic significance of right ventriculoarterial coupling in patients undergoing isolated tricuspid valve surgery. Prognostic role of persistent angina after percutaneous revascularization in chronic coronary syndrome with altered angiography and stress CMR. Recent advances in precision nutrition and cardiometabolic diseases.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1