Requirement analysis for an AI-based AR assistance system for surgical tools in the operating room: stakeholder requirements and technical perspectives.
E Cramer, A B Kucharski, J Kreimeier, S Andreß, S Li, C Walk, F Merkl, J Högl, P Wucherer, P Stefan, R von Eisenhart-Rothe, P Enste, D Roth
{"title":"Requirement analysis for an AI-based AR assistance system for surgical tools in the operating room: stakeholder requirements and technical perspectives.","authors":"E Cramer, A B Kucharski, J Kreimeier, S Andreß, S Li, C Walk, F Merkl, J Högl, P Wucherer, P Stefan, R von Eisenhart-Rothe, P Enste, D Roth","doi":"10.1007/s11548-024-03193-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>We aim to investigate the integration of augmented reality (AR) within the context of increasingly complex surgical procedures and instrument handling toward the transition to smart operating rooms (OR). In contrast to cumbersome paper-based surgical instrument manuals still used in the OR, we wish to provide surgical staff with an AR head-mounted display that provides in-situ visualization and guidance throughout the assembly process of surgical instruments. Our requirement analysis supports the development and provides guidelines for its transfer into surgical practice.</p><p><strong>Methods: </strong>A three-phase user-centered design approach was applied with online interviews, an observational study, and a workshop with two focus groups with scrub nurses, circulating nurses, surgeons, manufacturers, clinic IT staff, and members of the sterilization department. The requirement analysis was based on key criteria for usability. The data were analyzed via structured content analysis.</p><p><strong>Results: </strong>We identified twelve main problems with the current use of paper manuals. Major issues included sterile users' inability to directly handle non-sterile manuals, missing details, and excessive text information, potentially delaying procedure performance. Major requirements for AR-driven guidance fall into the categories of design, practicability, control, and integration into the current workflow. Additionally, further recommendations for technical development could be obtained.</p><p><strong>Conclusion: </strong>In conclusion, our insights have outlined a comprehensive spectrum of requirements that are essential for the successful implementation of an AI- and AR-driven guidance for assembling surgical instruments. The consistently appreciative evaluation by stakeholders underscores the profound potential of AR and AI technology as valuable assistance and guidance.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11541324/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03193-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: We aim to investigate the integration of augmented reality (AR) within the context of increasingly complex surgical procedures and instrument handling toward the transition to smart operating rooms (OR). In contrast to cumbersome paper-based surgical instrument manuals still used in the OR, we wish to provide surgical staff with an AR head-mounted display that provides in-situ visualization and guidance throughout the assembly process of surgical instruments. Our requirement analysis supports the development and provides guidelines for its transfer into surgical practice.
Methods: A three-phase user-centered design approach was applied with online interviews, an observational study, and a workshop with two focus groups with scrub nurses, circulating nurses, surgeons, manufacturers, clinic IT staff, and members of the sterilization department. The requirement analysis was based on key criteria for usability. The data were analyzed via structured content analysis.
Results: We identified twelve main problems with the current use of paper manuals. Major issues included sterile users' inability to directly handle non-sterile manuals, missing details, and excessive text information, potentially delaying procedure performance. Major requirements for AR-driven guidance fall into the categories of design, practicability, control, and integration into the current workflow. Additionally, further recommendations for technical development could be obtained.
Conclusion: In conclusion, our insights have outlined a comprehensive spectrum of requirements that are essential for the successful implementation of an AI- and AR-driven guidance for assembling surgical instruments. The consistently appreciative evaluation by stakeholders underscores the profound potential of AR and AI technology as valuable assistance and guidance.
目的:我们的目标是研究如何将增强现实技术(AR)与日益复杂的手术过程和器械处理相结合,以实现向智能手术室(OR)的过渡。与手术室仍在使用的繁琐的纸质手术器械手册相比,我们希望为手术人员提供一个 AR 头戴式显示器,在整个手术器械组装过程中提供现场可视化和指导。我们的需求分析为该产品的开发提供了支持,并为其在外科手术中的应用提供了指导:方法:我们采用了以用户为中心的三阶段设计方法,包括在线访谈、观察研究和研讨会,其中研讨会包含两个焦点小组,参加者包括擦洗护士、循环护士、外科医生、制造商、诊所 IT 人员和消毒部门成员。需求分析基于可用性的关键标准。通过结构化内容分析对数据进行了分析:我们发现了目前使用纸质手册存在的十二个主要问题。主要问题包括:无菌用户无法直接处理非无菌手册、细节缺失、文字信息过多,这些都有可能延误程序的执行。AR 驱动指南的主要要求包括设计、实用性、控制和与当前工作流程的整合。此外,还可以获得更多的技术发展建议:总之,我们的见解概述了成功实施人工智能和增强现实技术驱动的手术器械组装指导所必需的全面要求。利益相关者的一致好评强调了 AR 和 AI 技术作为有价值的辅助和指导的巨大潜力。
期刊介绍:
The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.