Efficacy of virtual surgical planning and a three-dimensional-printed, patient-specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study.
Logan M Scheuermann, Daniel D Lewis, Matthew D Johnson, Adam H Biedrzycki, Stanley E Kim
{"title":"Efficacy of virtual surgical planning and a three-dimensional-printed, patient-specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study.","authors":"Logan M Scheuermann, Daniel D Lewis, Matthew D Johnson, Adam H Biedrzycki, Stanley E Kim","doi":"10.1111/vsu.14118","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the efficacy of a three-dimensional (3D)-printed, patient-specific reduction system for aligning diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO).</p><p><strong>Study design: </strong>Prospective clinical trial.</p><p><strong>Sample population: </strong>Fifteen client owned dogs.</p><p><strong>Methods: </strong>Virtual 3D models of both pelvic limbs were created. Pin guides were designed to conform to the proximal and distal tibia. A reduction bridge was designed to align the pin guides based on the guides' spatial location. Guides were 3D printed, sterilized, and applied, in conjunction with transient application of a circular fixator, to facilitate indirect fracture realignment before plate application. Alignment of the stabilized tibiae was assessed using postoperative computed tomography scans.</p><p><strong>Results: </strong>Mean duration required for virtual planning was 2.5 h and a mean of 50.7 h elapsed between presentation and surgery. Guide placement was accurate with minor median discrepancies in translation and frontal, sagittal, and axial plane positioning of 2.9 mm, 3.6°, 2.7°, and 6.8°, respectively. Application of the reduction system restored mean tibial length and frontal, sagittal, and axial alignment within 1.7 mm, 1.9°, 1.7°, and 4.5°, respectively, of the contralateral tibia.</p><p><strong>Conclusion: </strong>Design and fabrication of a 3D-printed, patient-specific fracture reduction system is feasible in a relevant clinical timeline. Intraoperative pin-guide placement was reasonably accurate with minor discrepancies compared to the virtual plan. Custom 3D-printed reduction system application facilitated near-anatomic or acceptable fracture reduction in all dogs.</p><p><strong>Clinical significance: </strong>Virtual planning and fabrication of a 3D-printing patient-specific fracture reduction system is practical and facilitated acceptable, if not near-anatomic, fracture alignment during MIPO.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":"1039-1051"},"PeriodicalIF":1.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14118","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To evaluate the efficacy of a three-dimensional (3D)-printed, patient-specific reduction system for aligning diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO).
Study design: Prospective clinical trial.
Sample population: Fifteen client owned dogs.
Methods: Virtual 3D models of both pelvic limbs were created. Pin guides were designed to conform to the proximal and distal tibia. A reduction bridge was designed to align the pin guides based on the guides' spatial location. Guides were 3D printed, sterilized, and applied, in conjunction with transient application of a circular fixator, to facilitate indirect fracture realignment before plate application. Alignment of the stabilized tibiae was assessed using postoperative computed tomography scans.
Results: Mean duration required for virtual planning was 2.5 h and a mean of 50.7 h elapsed between presentation and surgery. Guide placement was accurate with minor median discrepancies in translation and frontal, sagittal, and axial plane positioning of 2.9 mm, 3.6°, 2.7°, and 6.8°, respectively. Application of the reduction system restored mean tibial length and frontal, sagittal, and axial alignment within 1.7 mm, 1.9°, 1.7°, and 4.5°, respectively, of the contralateral tibia.
Conclusion: Design and fabrication of a 3D-printed, patient-specific fracture reduction system is feasible in a relevant clinical timeline. Intraoperative pin-guide placement was reasonably accurate with minor discrepancies compared to the virtual plan. Custom 3D-printed reduction system application facilitated near-anatomic or acceptable fracture reduction in all dogs.
Clinical significance: Virtual planning and fabrication of a 3D-printing patient-specific fracture reduction system is practical and facilitated acceptable, if not near-anatomic, fracture alignment during MIPO.
期刊介绍:
Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations.
It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.