New Device for the Correction of Aphakia Without Capsular Support.

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-10-01 Epub Date: 2024-06-10 DOI:10.1080/02713683.2024.2362839
Victor Dias Bergamasco, Vagner Rogério Dos Santos, Bernardo Kaplan Moscovici, Mauro Campos
{"title":"New Device for the Correction of Aphakia Without Capsular Support.","authors":"Victor Dias Bergamasco, Vagner Rogério Dos Santos, Bernardo Kaplan Moscovici, Mauro Campos","doi":"10.1080/02713683.2024.2362839","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept.</p><p><strong>Methods: </strong>This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated.</p><p><strong>Results: </strong>Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics.</p><p><strong>Conclusions: </strong>The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2024.2362839","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept.

Methods: This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated.

Results: Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics.

Conclusions: The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于矫正无囊支持性无晶体眼的新设备。
目的:本研究描述了为无囊支持性无晶体眼(AWCS)开发的原型及其概念验证:这项描述性研究使用三维软件在制造前创建和分析虚拟原型。原型制作使用了尼龙-6/尼龙-6.6 共聚物长丝和三维打印机。使用 23 号皮下注射针开发了一种装置植入技术。在角膜缘后方 2 毫米处做了两个相对的标记,以确定巩膜穿刺的位置和装置的最终位置。在装置充分集中和定位后,对其触点进行切割和烧灼,以产生肢体热建模,并使尖端(凸缘)增厚,作为巩膜的固定机制。然后对该技术和装置的有效性和适当性进行了评估:结果:在巩膜切开术中未观察到玻璃体组织挤出。该装置与巩膜固定良好,但仍需实现足够的人工晶体稳定性和集中性。外科医生对所有其他装置的特性进行了评估:结论:开发用于矫正 AWCS 的技术原型是可行的。尽管所提出的原型符合大多数既定的概念准则,但人工晶体位置的稳定性仍是一项挑战。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Mentorship in academic musculoskeletal radiology: perspectives from a junior faculty member. Underlying synovial sarcoma undiagnosed for more than 20 years in a patient with regional pain: a case report. Sacrococcygeal chordoma with spontaneous regression due to a large hemorrhagic component. Associations of cumulative voriconazole dose, treatment duration, and alkaline phosphatase with voriconazole-induced periostitis. Can the presence of SLAP-5 lesions be predicted by using the critical shoulder angle in traumatic anterior shoulder instability?
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1