Rakan Algorinees, Asma Almohizea, Hind Aldalgan, Ibrahim Alobaida, Konrad Schargel, Seham Aljohar
{"title":"Outcomes of iStent versus endocyclophotocoagulation (ECP) as adjunct to cataract surgery by phacoemulsification for glaucoma patients.","authors":"Rakan Algorinees, Asma Almohizea, Hind Aldalgan, Ibrahim Alobaida, Konrad Schargel, Seham Aljohar","doi":"10.1177/11206721241261418","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the efficacy and safety of iStent versus Endocyclophotocoagulation (ECP) as an adjunct to cataract surgery by Phacoemulsification for treating glaucoma patients in a tertiary eye center.</p><p><strong>Methods: </strong>Retrospective study of 67 eyes of 61 patients with glaucoma and cataract who underwent either phaco-ECP or phaco-iStent. Primary efficacy endpoint is the Intraocular pressure (IOP) reduction, while reduction of glaucoma medications is the secondary outcome. In addition to IOP and number of glaucoma medications; visual acuity, degree of disc cupping, safety profiles were all assessed at different intervals up to 12 months.</p><p><strong>Results: </strong>A total of 40 eyes underwent phaco-ECP, and 27 eyes underwent phaco-iStent. Both groups were associated with a significant reduction in the number of glaucoma medications; however phaco-iStent group achieved slightly lower IOP levels than the phaco-ECP group. Furthermore, iStent inject had better control of IOP at the last follow-up compared to first-generation stents. Moreover; 2 or more stents significantly reduced IOP than single stent (<i>p</i> = 0.009 vs. <i>p</i> = 0.618, respectively). Phaco-iStent achieved a better reduction in the number of glaucoma medications for primary open-angle glaucoma (<i>p</i> = 0.007) compared to pseudoexfoliation glaucoma patients (<i>p</i> = 0.084). Complications were seen in 12 eyes (18%), of which five eyes in phaco-ECP (7.4%) and 7 eyes in phaco-iStent (10.4%), majority were mild and treated conservatively.</p><p><strong>Conclusions: </strong>Both groups had equal efficacy in reducing the IOP. However, phaco-iStent seems superior in reducing the number of glaucoma medications after 1 year of follow-up compared to phaco-ECP, particularly when 2 or more stents are used. Both groups showed an overall good safety profile.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":" ","pages":"206-213"},"PeriodicalIF":1.4000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241261418","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To compare the efficacy and safety of iStent versus Endocyclophotocoagulation (ECP) as an adjunct to cataract surgery by Phacoemulsification for treating glaucoma patients in a tertiary eye center.
Methods: Retrospective study of 67 eyes of 61 patients with glaucoma and cataract who underwent either phaco-ECP or phaco-iStent. Primary efficacy endpoint is the Intraocular pressure (IOP) reduction, while reduction of glaucoma medications is the secondary outcome. In addition to IOP and number of glaucoma medications; visual acuity, degree of disc cupping, safety profiles were all assessed at different intervals up to 12 months.
Results: A total of 40 eyes underwent phaco-ECP, and 27 eyes underwent phaco-iStent. Both groups were associated with a significant reduction in the number of glaucoma medications; however phaco-iStent group achieved slightly lower IOP levels than the phaco-ECP group. Furthermore, iStent inject had better control of IOP at the last follow-up compared to first-generation stents. Moreover; 2 or more stents significantly reduced IOP than single stent (p = 0.009 vs. p = 0.618, respectively). Phaco-iStent achieved a better reduction in the number of glaucoma medications for primary open-angle glaucoma (p = 0.007) compared to pseudoexfoliation glaucoma patients (p = 0.084). Complications were seen in 12 eyes (18%), of which five eyes in phaco-ECP (7.4%) and 7 eyes in phaco-iStent (10.4%), majority were mild and treated conservatively.
Conclusions: Both groups had equal efficacy in reducing the IOP. However, phaco-iStent seems superior in reducing the number of glaucoma medications after 1 year of follow-up compared to phaco-ECP, particularly when 2 or more stents are used. Both groups showed an overall good safety profile.
期刊介绍:
The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.