Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-06-11 DOI:10.1111/ocr.12822
Babak Sayahpour, Sara Eslami, Jakob Stuhlfelder, Sarah Bühling, Iulia Dahmer, Malcolm Goteni, Stefan Kopp, Ludovica Nucci
{"title":"Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment","authors":"Babak Sayahpour,&nbsp;Sara Eslami,&nbsp;Jakob Stuhlfelder,&nbsp;Sarah Bühling,&nbsp;Iulia Dahmer,&nbsp;Malcolm Goteni,&nbsp;Stefan Kopp,&nbsp;Ludovica Nucci","doi":"10.1111/ocr.12822","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>To compare and investigate the effects of intraoral ageing on the thickness of one group of directly printed and two groups of thermoformed aligners on the labial surface of maxillary central incisors.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Six groups (12 samples per group) were included in this prospective in vivo experiment. Groups DP-Clin, INV-Clin and CA-Clin consisted of directly printed (Tera Harz TC-85 DAC resin), thermoformed (Invisalign, PU based polymer) and in house thermoformed (CA-Pro, PET-G based polymer) aligners, retrieved after 1 week of intraoral service. Groups DP-Ctr, INV-Ctr and CA-Ctr included unused aligners samples. Thickness measurements were conducted using confocal laser scanning microscopy (CLSM). Data that underwent log-10 transformation was analysed by multiple linear regression analysis (<i>p</i> &lt; .05).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Statistically significant differences were found between the materials in both Clin and Ctr categories (<i>p</i> &lt; .001). Group DP had the highest thickness among the groups and the least thickness was observed in the CA group (<i>p</i> &lt; .001). However, intraoral ageing did not significantly affect the aligner thickness of any groups.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Both thermoforming and direct printing of clear aligners led to thickness deviations in terms of increase for printed aligners and decrease for thermoformed aligners. Intraoral ageing did not affect the aligner thickness in any of the groups.</p>\n </section>\n </div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-06-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/ocr.12822","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/ocr.12822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

To compare and investigate the effects of intraoral ageing on the thickness of one group of directly printed and two groups of thermoformed aligners on the labial surface of maxillary central incisors.

Materials and Methods

Six groups (12 samples per group) were included in this prospective in vivo experiment. Groups DP-Clin, INV-Clin and CA-Clin consisted of directly printed (Tera Harz TC-85 DAC resin), thermoformed (Invisalign, PU based polymer) and in house thermoformed (CA-Pro, PET-G based polymer) aligners, retrieved after 1 week of intraoral service. Groups DP-Ctr, INV-Ctr and CA-Ctr included unused aligners samples. Thickness measurements were conducted using confocal laser scanning microscopy (CLSM). Data that underwent log-10 transformation was analysed by multiple linear regression analysis (p < .05).

Results

Statistically significant differences were found between the materials in both Clin and Ctr categories (p < .001). Group DP had the highest thickness among the groups and the least thickness was observed in the CA group (p < .001). However, intraoral ageing did not significantly affect the aligner thickness of any groups.

Conclusions

Both thermoforming and direct printing of clear aligners led to thickness deviations in terms of increase for printed aligners and decrease for thermoformed aligners. Intraoral ageing did not affect the aligner thickness in any of the groups.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
评估 3D 打印与热成型矫治器的厚度:前瞻性体内老化实验。
背景:比较并研究口内老化对上颌中切牙唇面一组直接印制和两组热成型矫治器厚度的影响:本前瞻性活体实验包括六组(每组 12 个样本)。DP-Clin组、INV-Clin组和CA-Clin组包括直接印模(Tera Harz TC-85 DAC树脂)、热成型(Invisalign,聚氨酯聚合物)和室内热成型(CA-Pro,PET-G聚合物)矫治器,在口内使用1周后取回。DP-Ctr、INV-Ctr和CA-Ctr组包括未使用过的矫治器样本。厚度测量采用共焦激光扫描显微镜(CLSM)进行。对经过对数-10 转换的数据进行了多元线性回归分析(P 结果:在 Clin 和 Ctr 两个类别中,材料之间存在明显的统计学差异(p 结论:热成型和直接打印的矫治器厚度测量结果一致:热成型和直接印制透明矫治器都会导致厚度偏差,印制矫治器的厚度增加,而热成型矫治器的厚度减少。口内老化不影响任何一组的矫治器厚度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1