Prediction of footplate position after implantable collamer lens implantation based on iris and ciliary body morphologies.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY Journal of cataract and refractive surgery Pub Date : 2024-10-01 DOI:10.1097/j.jcrs.0000000000001500
Hao Wu, Yi-Ou Wang, Jiong-Pu Chen, Dong-Qiang Luo, Jiao Chen, Ding-Juan Zhong, Hua Wang
{"title":"Prediction of footplate position after implantable collamer lens implantation based on iris and ciliary body morphologies.","authors":"Hao Wu, Yi-Ou Wang, Jiong-Pu Chen, Dong-Qiang Luo, Jiao Chen, Ding-Juan Zhong, Hua Wang","doi":"10.1097/j.jcrs.0000000000001500","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the factors affecting footplate position and its influence on vault characteristics after implantable collamer lens (ICL) implantation.</p><p><strong>Setting: </strong>Hunan Provincial People's Hospital, Changsha, China.</p><p><strong>Design: </strong>Retrospective case series.</p><p><strong>Methods: </strong>This study included 124 patients (124 eyes). Ultrasound biomicroscopy (UBM) was performed to assess the iris and ciliary body morphologies and observe the footplate position. Using multiple linear regression, the relationship between various ocular and ICL parameters and the vault as well as the factors affecting the footplate distance (FD) were analyzed. Based on the FD, 3 groups were formed: group 1 (<500 μm), group 2 (500 to 1000 μm), and group 3 (>1000 μm). The distribution of the vault range postoperatively was observed for the 3 groups.</p><p><strong>Results: </strong>Ciliary sulcus angle and FD significantly affected the vault (adjusted R2 = 0.190, F = 6.763, P < .001), with FD being the most important factor influencing the vault (β = -0.383, P < .001). Postoperative UBM revealed that the footplate was located at different positions in the posterior chamber, with the majority (52%) being located on the ciliary body. The mean size of the 4 footplate orientations was 0.88 ± 0.24 mm. Multiple linear regression analysis revealed that ciliary body thickness (CBT), iris curvature (IC), and ICL iris contact length (IRCL) significantly influenced the FD (adjusted R2 = 0.373, F = 11.432, P < .001). The vault range differed significantly among the 3 groups (X 2 = 32.33, P < .001).</p><p><strong>Conclusions: </strong>Different postoperative ICL footplate positions significantly affect the vault. CBT, IC, and IRCL can alter the position of the footplate from the expected position. This study provides reference for ICL size selection and vault prediction.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"1006-1011"},"PeriodicalIF":2.6000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001500","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the factors affecting footplate position and its influence on vault characteristics after implantable collamer lens (ICL) implantation.

Setting: Hunan Provincial People's Hospital, Changsha, China.

Design: Retrospective case series.

Methods: This study included 124 patients (124 eyes). Ultrasound biomicroscopy (UBM) was performed to assess the iris and ciliary body morphologies and observe the footplate position. Using multiple linear regression, the relationship between various ocular and ICL parameters and the vault as well as the factors affecting the footplate distance (FD) were analyzed. Based on the FD, 3 groups were formed: group 1 (<500 μm), group 2 (500 to 1000 μm), and group 3 (>1000 μm). The distribution of the vault range postoperatively was observed for the 3 groups.

Results: Ciliary sulcus angle and FD significantly affected the vault (adjusted R2 = 0.190, F = 6.763, P < .001), with FD being the most important factor influencing the vault (β = -0.383, P < .001). Postoperative UBM revealed that the footplate was located at different positions in the posterior chamber, with the majority (52%) being located on the ciliary body. The mean size of the 4 footplate orientations was 0.88 ± 0.24 mm. Multiple linear regression analysis revealed that ciliary body thickness (CBT), iris curvature (IC), and ICL iris contact length (IRCL) significantly influenced the FD (adjusted R2 = 0.373, F = 11.432, P < .001). The vault range differed significantly among the 3 groups (X 2 = 32.33, P < .001).

Conclusions: Different postoperative ICL footplate positions significantly affect the vault. CBT, IC, and IRCL can alter the position of the footplate from the expected position. This study provides reference for ICL size selection and vault prediction.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据虹膜和睫状体形态预测植入式准分子人工晶体植入术后的脚板位置。
目的:探讨影响脚板位置的因素及其对植入性角膜接触镜(ICL)术后穹窿特征的影响:地点: 中国长沙湖南省人民医院:设计:回顾性病例系列:本研究共纳入 124 名患者(124 只眼)。采用超声生物显微镜(UBM)评估虹膜和睫状体形态并观察脚板位置。使用多元线性回归分析了各种眼球和 ICL 参数与穹窿之间的关系,以及影响脚板距离(FD)的因素。根据脚板距离分为三组:第一组(1000 微米);第二组(1000 微米);第三组(1000 微米)。观察三组术后穹窿范围的分布:结果:睫状沟角度和FD对穹窿有显著影响(调整后R2=0.190,F=6.763,PC结论):不同的术后ICL脚板位置对穹窿有明显影响。CBT、IC和IRCL会改变脚板的位置,使其偏离预期位置。本研究为 ICL 大小选择和穹窿预测提供了参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
期刊最新文献
Ocular Shape of Cataract with Retinitis Pigmentosa: A Case-Control Study. Intraocular Lens Rotational Stability after Cataract Surgery with and without Primary Posterior Continuous Curvilinear Capsulorrhexis. Risk of Zonular Dialysis in Fellow-Eye Cataract Surgeries: A Multicenter Comparative Study. Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema. Analysis of the ESCRS calculator's prediction accuracy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1