{"title":"A robot-assisted tracheal intubation system based on a soft actuator?","authors":"Jiayuan Liu, Longfei Ma, Chengquan Hu, Jingyi Kang, Boyu Zhang, Ruiyang Li, Hongen Liao","doi":"10.1007/s11548-024-03209-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Tracheal intubation is the gold standard of airway protection and constitutes a pivotal life-saving technique frequently employed in emergency medical interventions. Hence, in this paper, a system is designed to execute tracheal intubation tasks automatically, offering a safer and more efficient solution, thereby alleviating the burden on physicians.</p><p><strong>Methods: </strong>The system comprises a tracheal tube with a bendable front end, a drive system, and a tip endoscope. The soft actuator provides two degrees of freedom for precise orientation. It is fabricated with varying-hardness silicone and reinforced with fibers and spiral steel wire for flexibility and safety. The hydraulic actuation system and tube feeding mechanism enable controlled bending and delivery. Object detection of key anatomical features guides the robotic arm and soft actuator. The control strategy involves visual servo control for coordinated robotic arm and soft actuator movements, ensuring accurate and safe tracheal intubation.</p><p><strong>Results: </strong>The kinematics of the soft actuator were established using a constant curvature model, allowing simulation of its workspace. Through experiments, the actuator is capable of 90° bending as well as 20° deflection on the left and right sides. The maximum insertion force of the tube is 2 N. Autonomous tracheal intubation experiments on a training manikin were successful in all 10 trials, with an average insertion time of 45.6 s.</p><p><strong>Conclusion: </strong>Experimental validation on the manikin demonstrated that the robot tracheal intubation system based on a soft actuator was able to perform safe, stable, and automated tracheal intubation. In summary, this paper proposed a safe and automated robot-assisted tracheal intubation system based on a soft actuator, showing considerable potential for clinical applications.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03209-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Tracheal intubation is the gold standard of airway protection and constitutes a pivotal life-saving technique frequently employed in emergency medical interventions. Hence, in this paper, a system is designed to execute tracheal intubation tasks automatically, offering a safer and more efficient solution, thereby alleviating the burden on physicians.

Methods: The system comprises a tracheal tube with a bendable front end, a drive system, and a tip endoscope. The soft actuator provides two degrees of freedom for precise orientation. It is fabricated with varying-hardness silicone and reinforced with fibers and spiral steel wire for flexibility and safety. The hydraulic actuation system and tube feeding mechanism enable controlled bending and delivery. Object detection of key anatomical features guides the robotic arm and soft actuator. The control strategy involves visual servo control for coordinated robotic arm and soft actuator movements, ensuring accurate and safe tracheal intubation.

Results: The kinematics of the soft actuator were established using a constant curvature model, allowing simulation of its workspace. Through experiments, the actuator is capable of 90° bending as well as 20° deflection on the left and right sides. The maximum insertion force of the tube is 2 N. Autonomous tracheal intubation experiments on a training manikin were successful in all 10 trials, with an average insertion time of 45.6 s.

Conclusion: Experimental validation on the manikin demonstrated that the robot tracheal intubation system based on a soft actuator was able to perform safe, stable, and automated tracheal intubation. In summary, this paper proposed a safe and automated robot-assisted tracheal intubation system based on a soft actuator, showing considerable potential for clinical applications.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于软推杆的机器人辅助气管插管系统?
目的:气管插管是气道保护的黄金标准,是紧急医疗干预中经常使用的关键救生技术。因此,本文设计了一种自动执行气管插管任务的系统,提供更安全、更高效的解决方案,从而减轻医生的负担:该系统由一个前端可弯曲的气管导管、一个驱动系统和一个尖端内窥镜组成。软驱动器具有两个自由度,可精确定位。它由不同硬度的硅胶制成,并用纤维和螺旋钢丝加固,具有柔韧性和安全性。液压致动系统和输液管进给机制可实现可控的弯曲和输送。关键解剖特征的目标检测为机械臂和软驱动器提供指导。控制策略包括视觉伺服控制,以协调机械臂和软推杆的运动,确保气管插管的准确性和安全性:结果:使用恒定曲率模型建立了软致动器的运动学,从而可以模拟其工作空间。通过实验,推杆能够进行 90° 的弯曲以及左右 20° 的偏转。在训练用人体模型上进行的自主气管插管实验在所有 10 次试验中均获得成功,平均插管时间为 45.6 秒:在人体模型上进行的实验验证表明,基于软推杆的机器人气管插管系统能够安全、稳定、自动地进行气管插管。综上所述,本文提出了一种基于软致动器的安全、自动化机器人辅助气管插管系统,在临床应用方面具有相当大的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
期刊最新文献
Optimization of percutaneous intervention robotic system for skin insertion force. Correction to: Micro-robotic percutaneous targeting of type II endoleaks in the angio-suite. Automated assessment of non-technical skills by heart-rate data. Artificial intelligence-based analysis of lower limb muscle mass and fatty degeneration in patients with knee osteoarthritis and its correlation with Knee Society Score. High-quality semi-supervised anomaly detection with generative adversarial networks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1