Ultrasound role in diagnosis and as an assisting tool in prognostication of surgery in neonates with necrotizing enterocolitis

Elham Zarei , Mehdi Vafadar , Amir S. Mounesi Sohi , Jilla Armandeh , Ehsan Ranjbar
{"title":"Ultrasound role in diagnosis and as an assisting tool in prognostication of surgery in neonates with necrotizing enterocolitis","authors":"Elham Zarei ,&nbsp;Mehdi Vafadar ,&nbsp;Amir S. Mounesi Sohi ,&nbsp;Jilla Armandeh ,&nbsp;Ehsan Ranjbar","doi":"10.1016/j.wfumbo.2024.100048","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Abdominal ultrasonography (AUS) assessment of the neonatal abdomen is emerging as a potential useful addition to traditional abdominal radiographs (AXR) to confirm the diagnosis of necrotizing enterocolitis (NEC). The goal of this study was to assess the abdominal sonographic findings of premature infants with NEC, in order to determine whether AUS is more effective than AXR in the diagnosis of NEC.</p></div><div><h3>Methods</h3><p>This cross-sectional study was performed on consecutive neonates with clinical suspicion of NEC admitted in our hospital’s NICU (Ali-Asghar Children’s Hospital, Tehran, Iran). We prospectively evaluated the hospitalized subjects using AXR and AUS from May 2018 to May 2020.</p></div><div><h3>Results</h3><p>A total of 53 neonates were included in the study. These patients were divided into two groups: suspected NEC patients (stage I) including 31 subjects and definite NEC patients (stage II and III) including 22 neonates. We found a substantial agreement between the two modalities regarding the detection of pneumoperitoneum and pneumatosis intestinalis (κ: 0·658 for both). The concordance concerning portal venous gas detection was considered slight (κ: 0·315). Thirty-eight patients did not show any signs of portal venous gas in either of AUS or AXR. On the contrary, four patients demonstrated evidences of portal venous gas in both AUS and AXR. AUS detected ten more portal venous gas than AXR. AXR found no cases with positive portal venous gas that were undetected by AUS. The most predictive indicator for surgical intervention in neonates was the presence of free echogenic ascites and loculated fluid.</p></div><div><h3>Conclusion</h3><p>Our findings demonstrated that AUS is superior to AXR in demonstrating portal venous gas and pneumatosis intestinalis. Hence, it seems that AUS is a useful adjunct to AXR in the management of NEC.</p></div>","PeriodicalId":101281,"journal":{"name":"WFUMB Ultrasound Open","volume":"2 2","pages":"Article 100048"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949668324000168/pdfft?md5=fbf6aec924c4dc158f65ae6bbae8b53f&pid=1-s2.0-S2949668324000168-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"WFUMB Ultrasound Open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949668324000168","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

Abdominal ultrasonography (AUS) assessment of the neonatal abdomen is emerging as a potential useful addition to traditional abdominal radiographs (AXR) to confirm the diagnosis of necrotizing enterocolitis (NEC). The goal of this study was to assess the abdominal sonographic findings of premature infants with NEC, in order to determine whether AUS is more effective than AXR in the diagnosis of NEC.

Methods

This cross-sectional study was performed on consecutive neonates with clinical suspicion of NEC admitted in our hospital’s NICU (Ali-Asghar Children’s Hospital, Tehran, Iran). We prospectively evaluated the hospitalized subjects using AXR and AUS from May 2018 to May 2020.

Results

A total of 53 neonates were included in the study. These patients were divided into two groups: suspected NEC patients (stage I) including 31 subjects and definite NEC patients (stage II and III) including 22 neonates. We found a substantial agreement between the two modalities regarding the detection of pneumoperitoneum and pneumatosis intestinalis (κ: 0·658 for both). The concordance concerning portal venous gas detection was considered slight (κ: 0·315). Thirty-eight patients did not show any signs of portal venous gas in either of AUS or AXR. On the contrary, four patients demonstrated evidences of portal venous gas in both AUS and AXR. AUS detected ten more portal venous gas than AXR. AXR found no cases with positive portal venous gas that were undetected by AUS. The most predictive indicator for surgical intervention in neonates was the presence of free echogenic ascites and loculated fluid.

Conclusion

Our findings demonstrated that AUS is superior to AXR in demonstrating portal venous gas and pneumatosis intestinalis. Hence, it seems that AUS is a useful adjunct to AXR in the management of NEC.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声波在新生儿坏死性小肠结肠炎的诊断和手术预后中的辅助作用
目的 对新生儿腹部进行腹部超声波检查(AUS)是对传统腹部X光检查(AXR)的一种潜在补充,可用于确诊坏死性小肠结肠炎(NEC)。这项研究的目的是评估患有 NEC 的早产儿的腹部超声波检查结果,以确定 AUS 在诊断 NEC 方面是否比 AXR 更有效。方法这项横断面研究的对象是我院新生儿重症监护室(伊朗德黑兰阿里-阿斯哈尔儿童医院)连续收治的临床怀疑患有 NEC 的新生儿。从 2018 年 5 月到 2020 年 5 月,我们使用 AXR 和 AUS 对住院对象进行了前瞻性评估。这些患者被分为两组:疑似 NEC 患者(I 期)(包括 31 名受试者)和确诊 NEC 患者(II 期和 III 期)(包括 22 名新生儿)。我们发现,在腹腔积气和肠道积气的检测方面,两种方法的结果非常一致(κ:均为 0-658)。门静脉气体检测的一致性被认为很低(κ:0-315)。38 名患者在 AUS 或 AXR 中均未显示任何门静脉气体迹象。相反,有四名患者在 AUS 和 AXR 中均显示出门静脉积气的迹象。AUS 比 AXR 多检测出 10 例门静脉气体。AXR 没有发现 AUS 检测不到的门静脉气体阳性病例。我们的研究结果表明,AUS 在显示门静脉积气和肠道积气方面优于 AXR。因此,在治疗 NEC 时,AUS 似乎是 AXR 的有效辅助手段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Added clinical advantage of combining ultrasound with radiograph in assessing ankle injuries: Comparison with MRI Treatment of inoperable pancreatic adenocarcinoma with focused ultrasound and microbubbles in patients receiving chemotherapy Breast cancer ultrasound image segmentation using improved 3DUnet++ Utilization of evoked vibrational signatures under ultrasound examination as a novel method of tissue classification Protocol refinement and inter- and intra-rater reliability assessment of ultrasound-based measurements of hamstring architecture, and echo intensity, and intra-rater reliability of shear wave elastography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1