Identifying an acceptable number of ambulatory blood pressure measurements for accuracy of average blood pressure and nocturnal dipping status.

IF 4.1 2区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS American journal of physiology. Heart and circulatory physiology Pub Date : 2024-08-01 Epub Date: 2024-06-14 DOI:10.1152/ajpheart.00220.2024
Leandro C Brito, Sean P M Rice, Nicole P Bowles, Matthew P Butler, Andrew W McHill, Jonathan S Emens, Steven A Shea, Saurabh S Thosar
{"title":"Identifying an acceptable number of ambulatory blood pressure measurements for accuracy of average blood pressure and nocturnal dipping status.","authors":"Leandro C Brito, Sean P M Rice, Nicole P Bowles, Matthew P Butler, Andrew W McHill, Jonathan S Emens, Steven A Shea, Saurabh S Thosar","doi":"10.1152/ajpheart.00220.2024","DOIUrl":null,"url":null,"abstract":"<p><p>We aimed to identify the minimum number of ambulatory blood pressure (ABP) measures to accurately determine daytime and nighttime systolic blood pressure (BP) averages and nocturnal dipping status (i.e., relative daytime:nighttime change). A total of 43 midlife participants wore an ABP monitor for 24 h with measurements every 20/30 min during the daytime/nighttime, as identified by a sleep diary. We calculated daytime/nighttime systolic BP average and dipping status from all available measurements per participant (i.e., normative data). We then calculated daytime and nighttime BP per participant based on a random selection of 8-20 and 4-10 measurements and replicated random selections 1,000 times. We calculated accuracy by checking the proportion from 1,000 different randomly selected samples for a particular number of measurements that systolic BP was ±5 mmHg of normative data, and dipping status remained unchanged for each participant compared with the normative value. The best fit for the regression model estimated the minimal number of measurements for an accuracy of 95% in BP averages. For a 95% accuracy in estimating daytime and nighttime systolic BP, 11 daytime and 8 nighttime measurements were required. The highest accuracy for dipping status was 91.6 ± 13.4% using 20 daytime and 10 nighttime measures, while the lowest was (83.4 ± 15.1%) using 8 daytime and 4 nighttime measures. In midlife adults, 11 daytime and 8 nighttime measurements are likely enough to calculate average systolic BPs accurately. However, no minimum number is suggested to accurately calculate dipping status.<b>NEW & NOTEWORTHY</b> We found that a minimum of 11 blood pressure (BP) measures are necessary to calculate an accurate average daytime BP, and 8 nighttime measures are necessary to calculate an accurate nighttime average if 95% accuracy is acceptable. Regarding BP dipping status, the current recommendations (20 daytime/7 nighttime) inaccurately classified the dipping status 10.5% of the time, suggesting that guidelines may need to be updated to classify patients as nocturnal dippers or nondippers correctly.</p>","PeriodicalId":7692,"journal":{"name":"American journal of physiology. Heart and circulatory physiology","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11442022/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of physiology. Heart and circulatory physiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1152/ajpheart.00220.2024","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/14 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

We aimed to identify the minimum number of ambulatory blood pressure (ABP) measures to accurately determine daytime and nighttime systolic blood pressure (BP) averages and nocturnal dipping status (i.e., relative daytime:nighttime change). A total of 43 midlife participants wore an ABP monitor for 24 h with measurements every 20/30 min during the daytime/nighttime, as identified by a sleep diary. We calculated daytime/nighttime systolic BP average and dipping status from all available measurements per participant (i.e., normative data). We then calculated daytime and nighttime BP per participant based on a random selection of 8-20 and 4-10 measurements and replicated random selections 1,000 times. We calculated accuracy by checking the proportion from 1,000 different randomly selected samples for a particular number of measurements that systolic BP was ±5 mmHg of normative data, and dipping status remained unchanged for each participant compared with the normative value. The best fit for the regression model estimated the minimal number of measurements for an accuracy of 95% in BP averages. For a 95% accuracy in estimating daytime and nighttime systolic BP, 11 daytime and 8 nighttime measurements were required. The highest accuracy for dipping status was 91.6 ± 13.4% using 20 daytime and 10 nighttime measures, while the lowest was (83.4 ± 15.1%) using 8 daytime and 4 nighttime measures. In midlife adults, 11 daytime and 8 nighttime measurements are likely enough to calculate average systolic BPs accurately. However, no minimum number is suggested to accurately calculate dipping status.NEW & NOTEWORTHY We found that a minimum of 11 blood pressure (BP) measures are necessary to calculate an accurate average daytime BP, and 8 nighttime measures are necessary to calculate an accurate nighttime average if 95% accuracy is acceptable. Regarding BP dipping status, the current recommendations (20 daytime/7 nighttime) inaccurately classified the dipping status 10.5% of the time, suggesting that guidelines may need to be updated to classify patients as nocturnal dippers or nondippers correctly.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
确定可接受的动态血压测量次数,以保证平均血压和夜间骤降状态的准确性。
目的:我们旨在确定最少的 ABP 测量次数,以准确确定昼夜收缩压平均值和夜间下降状态(即昼夜相对变化):43 名中年参与者佩戴 ABP 监测器 24 小时,根据睡眠日记确定白天/夜间每 20/30 分钟测量一次。我们根据每位参与者的所有可用测量数据(即常模数据)计算出白天/夜间收缩压平均值和骤降状态。然后,我们根据随机抽取的 8-20 个测量值和 4-10 个测量值计算每位受试者的日间和夜间血压,并重复随机抽取 1000 次。我们计算精确度的方法是从 1000 个不同的随机抽取样本中检查特定测量次数的比例,即收缩压与常模数据相差±5 mmHg,且每位参与者的浸润状态与常模值相比保持不变。回归模型的最佳拟合估计了血压平均值准确率达到 95% 的最少测量次数:结果:要使日间和夜间收缩压的估计准确率达到 95%,需要进行 11 次日间测量和 8 次夜间测量。采用 20 次日间测量和 10 次夜间测量,浸润状态的准确率最高,为 91.6±13.4%;采用 8 次日间测量和 4 次夜间测量,准确率最低,为(83.4±15.1%):结论:11 次日间测量和 8 次夜间测量足以准确计算平均收缩压。结论:11 次日间测量和 8 次夜间测量足以准确计算出平均收缩压,但没有提出准确计算浸润状态的最低次数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
9.60
自引率
10.40%
发文量
202
审稿时长
2-4 weeks
期刊介绍: The American Journal of Physiology-Heart and Circulatory Physiology publishes original investigations, reviews and perspectives on the physiology of the heart, vasculature, and lymphatics. These articles include experimental and theoretical studies of cardiovascular function at all levels of organization ranging from the intact and integrative animal and organ function to the cellular, subcellular, and molecular levels. The journal embraces new descriptions of these functions and their control systems, as well as their basis in biochemistry, biophysics, genetics, and cell biology. Preference is given to research that provides significant new mechanistic physiological insights that determine the performance of the normal and abnormal heart and circulation.
期刊最新文献
Usp20 deletion promotes eccentric cardiac remodeling in response to pressure overload and increases mortality. Characterizing Vascular and Hormonal Changes in Women Across the Lifespan: A Cross-Sectional Analysis. Nanoscale organization of cardiac calcium channels is dependent on thyroid hormone status. Under Pressure: Does Antenatal Stress Last Until Adulthood. Very low-density lipoprotein receptor mediates triglyceride-rich lipoprotein-induced oxidative stress and insulin resistance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1