Simultaneous Injection of Contrast and Saline Using Spiral Flow-Generating Tube for Hepatic Dynamic Computed Tomography: Effect on Enhancement of Liver Parenchyma and Metastases to the Liver.
{"title":"Simultaneous Injection of Contrast and Saline Using Spiral Flow-Generating Tube for Hepatic Dynamic Computed Tomography: Effect on Enhancement of Liver Parenchyma and Metastases to the Liver.","authors":"Hiroji Nagata, Hisako Iori, Shiori Yoshida, Hiroki Kawashima, Yuka Nishino, Ryo Sakasai, Hiroshi Yamamura, Tetsuya Minami","doi":"10.1097/RCT.0000000000001620","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Recently, there have been a few reports regarding the usefulness of a novel saline injection technique using a spiral flow-generating tube. The purpose of this study was to evaluate whether simultaneous saline injection using a spiral flow-generating tube was able to improve hepatic contrast enhancement and lesion conspicuity of metastatic liver tumors.</p><p><strong>Methods: </strong>We randomized a total of 411 patients with various liver diseases including metastases by total body weight (A, n = 204) and contrast dilution protocol (B, n = 207). Group A received 400 mgI/kg of contrast medium alone without a spiral flow-generating tube; group B received contrast medium 400 mgI/kg simultaneous with injection of a 0.57-ml/kg physiologic saline solution through a spiral flow-generating tube. Abdominal aorta computed tomography (CT) number, hepatic enhancement (ΔHU), percentage of tests demonstrating an enhancement effect of the liver parenchyma exceeding Δ50 HU in 3 measured segments (S2, S6, and S8), and the contrast-to-noise ratio of the metastatic liver tumors were measured.</p><p><strong>Results: </strong>The mean aortic CT number of group B (417.0 HU ± 61.7; P < 0.01) was approximately 10% higher than that of group A (384.6 ± 79.1 HU). The average ΔHU was 59.8 ± 11.4 HU for group A and 61.7 ± 11.7 for group B. The ΔHU for group B was significantly higher than that for group A (P = 0.017). The percentage of tests demonstrating with the enhancement effect of group B was more than 80% in all subgroups; however, that of group A was less than 80% in all subgroups. The contrast-to-noise ratio of group B (7.8 ± 3.3 HU) was significantly higher compared to that of group A (6.5 ± 2.8 HU) (P < 0.05).</p><p><strong>Conclusions: </strong>Because of the volume effect, injecting a contrast medium diluted with normal saline improved the degree of hepatic and aortic contrast enhancement and achieved better visualization of liver metastases.</p><p><strong>Clinical impact: </strong>The use of spiral flow-generating tube may help diagnostic of hepatic and aortic contrast enhancement and liver metastases.</p><p><strong>Importance: </strong>The use of a spiral flow-generating tube improved the degree of hepatic and aortic contrast enhancement and achieve better visualization of liver metastases.</p><p><strong>Points: </strong>The use of low-concentration syringe formulations is limited by body weight. However, the use of spiral flow-generating tube provides low-concentration contrast medium regardless of body weight.</p>","PeriodicalId":15402,"journal":{"name":"Journal of Computer Assisted Tomography","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computer Assisted Tomography","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RCT.0000000000001620","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Recently, there have been a few reports regarding the usefulness of a novel saline injection technique using a spiral flow-generating tube. The purpose of this study was to evaluate whether simultaneous saline injection using a spiral flow-generating tube was able to improve hepatic contrast enhancement and lesion conspicuity of metastatic liver tumors.
Methods: We randomized a total of 411 patients with various liver diseases including metastases by total body weight (A, n = 204) and contrast dilution protocol (B, n = 207). Group A received 400 mgI/kg of contrast medium alone without a spiral flow-generating tube; group B received contrast medium 400 mgI/kg simultaneous with injection of a 0.57-ml/kg physiologic saline solution through a spiral flow-generating tube. Abdominal aorta computed tomography (CT) number, hepatic enhancement (ΔHU), percentage of tests demonstrating an enhancement effect of the liver parenchyma exceeding Δ50 HU in 3 measured segments (S2, S6, and S8), and the contrast-to-noise ratio of the metastatic liver tumors were measured.
Results: The mean aortic CT number of group B (417.0 HU ± 61.7; P < 0.01) was approximately 10% higher than that of group A (384.6 ± 79.1 HU). The average ΔHU was 59.8 ± 11.4 HU for group A and 61.7 ± 11.7 for group B. The ΔHU for group B was significantly higher than that for group A (P = 0.017). The percentage of tests demonstrating with the enhancement effect of group B was more than 80% in all subgroups; however, that of group A was less than 80% in all subgroups. The contrast-to-noise ratio of group B (7.8 ± 3.3 HU) was significantly higher compared to that of group A (6.5 ± 2.8 HU) (P < 0.05).
Conclusions: Because of the volume effect, injecting a contrast medium diluted with normal saline improved the degree of hepatic and aortic contrast enhancement and achieved better visualization of liver metastases.
Clinical impact: The use of spiral flow-generating tube may help diagnostic of hepatic and aortic contrast enhancement and liver metastases.
Importance: The use of a spiral flow-generating tube improved the degree of hepatic and aortic contrast enhancement and achieve better visualization of liver metastases.
Points: The use of low-concentration syringe formulations is limited by body weight. However, the use of spiral flow-generating tube provides low-concentration contrast medium regardless of body weight.
期刊介绍:
The mission of Journal of Computer Assisted Tomography is to showcase the latest clinical and research developments in CT, MR, and closely related diagnostic techniques. We encourage submission of both original research and review articles that have immediate or promissory clinical applications. Topics of special interest include: 1) functional MR and CT of the brain and body; 2) advanced/innovative MRI techniques (diffusion, perfusion, rapid scanning); and 3) advanced/innovative CT techniques (perfusion, multi-energy, dose-reduction, and processing).