{"title":"Airborne and surface contamination after rotational intraperitoneal pressurized aerosol chemotherapy using cisplatin.","authors":"Wongeon Jung, Mijin Park, Soo Jin Park, Eun Ji Lee, Hee Seung Kim, Sunju Kim, Chungsik Yoon","doi":"10.3802/jgo.2025.36.e12","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>We evaluated the occupational exposure levels of healthcare workers while conducting rotational pressurized intraperitoneal aerosol chemotherapy (RIPAC) using cisplatin in a large animal model.</p><p><strong>Methods: </strong>We performed RIPAC using cisplatin in 6 female pigs and collected surface and air samples during the procedure. Surface samples were obtained from RIPAC devices and personal protective equipment (PPE) by wiping, and air samples were collected around the operating table. All samples were analyzed by inductively coupled plasma-mass spectrometry to detect platinum.</p><p><strong>Results: </strong>Among all surface samples (n=44), platinum was detected in 41 samples (93.2%) but not in all air samples (n=16). Among samples collected from RIPAC devices (n=23), minimum and maximum cisplatin levels of 0.08 and 235.09 ng/cm² were detected, mainly because of direct aerosol exposure in the abdominal cavity. Among samples collected from healthcare workers' PPE (n=21), 18 samples (85.7%) showed contamination levels below the detection limit, with a maximum of 0.23 ng/cm². There was no significant contamination among samples collected from masks, shoes, or gloves.</p><p><strong>Conclusion: </strong>During the RIPAC procedures, there is a potential risk of dermal exposure, as platinum, a surrogate material for cisplatin, was detected at low concentration levels in some surface samples. However, the respiratory exposure risk was not identified, as platinum was not detected in the airborne samples in this study.</p>","PeriodicalId":15868,"journal":{"name":"Journal of Gynecologic Oncology","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Gynecologic Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3802/jgo.2025.36.e12","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: We evaluated the occupational exposure levels of healthcare workers while conducting rotational pressurized intraperitoneal aerosol chemotherapy (RIPAC) using cisplatin in a large animal model.
Methods: We performed RIPAC using cisplatin in 6 female pigs and collected surface and air samples during the procedure. Surface samples were obtained from RIPAC devices and personal protective equipment (PPE) by wiping, and air samples were collected around the operating table. All samples were analyzed by inductively coupled plasma-mass spectrometry to detect platinum.
Results: Among all surface samples (n=44), platinum was detected in 41 samples (93.2%) but not in all air samples (n=16). Among samples collected from RIPAC devices (n=23), minimum and maximum cisplatin levels of 0.08 and 235.09 ng/cm² were detected, mainly because of direct aerosol exposure in the abdominal cavity. Among samples collected from healthcare workers' PPE (n=21), 18 samples (85.7%) showed contamination levels below the detection limit, with a maximum of 0.23 ng/cm². There was no significant contamination among samples collected from masks, shoes, or gloves.
Conclusion: During the RIPAC procedures, there is a potential risk of dermal exposure, as platinum, a surrogate material for cisplatin, was detected at low concentration levels in some surface samples. However, the respiratory exposure risk was not identified, as platinum was not detected in the airborne samples in this study.
期刊介绍:
The Journal of Gynecologic Oncology (JGO) is an official publication of the Asian Society of Gynecologic Oncology. Abbreviated title is ''J Gynecol Oncol''. It was launched in 1990. The JGO''s aim is to publish the highest quality manuscripts dedicated to the advancement of care of the patients with gynecologic cancer. It is an international peer-reviewed periodical journal that is published bimonthly (January, March, May, July, September, and November). Supplement numbers are at times published. The journal publishes editorials, original and review articles, correspondence, book review, etc.