{"title":"The association of COVID-19 with increased pediatric ventriculoatrial shunt failures: a national retrospective cohort.","authors":"Uma V Mahajan, Dana Defta, David C Kaelber, Sanjay P Ahuja, Brian D Rothstein, Krystal L Tomei","doi":"10.3171/2024.4.PEDS23517","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>During the COVID-19 pandemic, the authors' institution managed ventriculoatrial (VA) shunt complications in 2 teenage patients in close proximity to a symptomatic COVID-19 infection. Systemic thrombotic events are an established complication of COVID-19 infection due to a hypercoagulable state. Thrombotic complications, particularly elevated central venous pressure, can cause VA shunt failure. The true effect of COVID-19 on patients with intravascular devices is currently unknown. In this study, the authors aimed to determine if there was an association between COVID-19 infection and VA shunt failure.</p><p><strong>Methods: </strong>TriNetX, an aggregated electronic health record platform, was used to analyze data of more than 13 million US pediatric patients. Two matched cohorts of patients < 18 years of age with a VA shunt were defined. Group 1 (n = 311) had a positive laboratory test for COVID-19 from March 1, 2020, to March 31, 2022. Group 2 (n = 311), a control group, had any medical appointment from March 1, 2020, to March 31, 2022, and never had a positive laboratory test for COVID-19. The authors analyzed outcomes 1 year after testing positive for COVID-19 in group 1, and after the medical appointment in group 2. Outcomes included shunt complications, shunt revisions or replacements, and thromboembolic complications. To protect patient privacy, individual results of fewer than 10 patients are not specified in TriNetX.</p><p><strong>Results: </strong>Group 1 had a greater odds of mechanical shunt complication than group 2 (20% vs 4%, OR 5.71, 95% CI 3.07-10.62). Group 1 had a greater odds of shunt reoperation than group 2 (11% vs < 3%, OR > 3.7, 95% CI 1.72-7.62). There were 1-10 patients in group 1 (≤ 3% of group 1) who experienced a thromboembolism due to the shunt, compared with no patients in group 2 who had a thromboembolism due to the shunt.</p><p><strong>Conclusions: </strong>This analysis demonstrates an association of shunt complications, reoperations, and thromboembolic events in patients with VA shunts following COVID-19 infection.</p>","PeriodicalId":16549,"journal":{"name":"Journal of neurosurgery. Pediatrics","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2024-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Pediatrics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3171/2024.4.PEDS23517","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/1 0:00:00","PubModel":"Print","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: During the COVID-19 pandemic, the authors' institution managed ventriculoatrial (VA) shunt complications in 2 teenage patients in close proximity to a symptomatic COVID-19 infection. Systemic thrombotic events are an established complication of COVID-19 infection due to a hypercoagulable state. Thrombotic complications, particularly elevated central venous pressure, can cause VA shunt failure. The true effect of COVID-19 on patients with intravascular devices is currently unknown. In this study, the authors aimed to determine if there was an association between COVID-19 infection and VA shunt failure.

Methods: TriNetX, an aggregated electronic health record platform, was used to analyze data of more than 13 million US pediatric patients. Two matched cohorts of patients < 18 years of age with a VA shunt were defined. Group 1 (n = 311) had a positive laboratory test for COVID-19 from March 1, 2020, to March 31, 2022. Group 2 (n = 311), a control group, had any medical appointment from March 1, 2020, to March 31, 2022, and never had a positive laboratory test for COVID-19. The authors analyzed outcomes 1 year after testing positive for COVID-19 in group 1, and after the medical appointment in group 2. Outcomes included shunt complications, shunt revisions or replacements, and thromboembolic complications. To protect patient privacy, individual results of fewer than 10 patients are not specified in TriNetX.

Results: Group 1 had a greater odds of mechanical shunt complication than group 2 (20% vs 4%, OR 5.71, 95% CI 3.07-10.62). Group 1 had a greater odds of shunt reoperation than group 2 (11% vs < 3%, OR > 3.7, 95% CI 1.72-7.62). There were 1-10 patients in group 1 (≤ 3% of group 1) who experienced a thromboembolism due to the shunt, compared with no patients in group 2 who had a thromboembolism due to the shunt.

Conclusions: This analysis demonstrates an association of shunt complications, reoperations, and thromboembolic events in patients with VA shunts following COVID-19 infection.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
COVID-19与小儿脑室-心房分流术失败率增加的关系:全国回顾性队列。
目的:在 COVID-19 大流行期间,作者所在的医疗机构处理了两名青少年患者的脑室-心房(VA)分流并发症,这两名患者与有症状的 COVID-19 感染病例十分接近。由于高凝状态,全身性血栓事件是 COVID-19 感染的既定并发症。血栓并发症,尤其是中心静脉压升高,可导致 VA 分流失败。目前尚不清楚 COVID-19 对使用血管内装置的患者的真正影响。在这项研究中,作者旨在确定 COVID-19 感染与 VA 分流失败之间是否存在关联:方法:作者使用聚合电子健康记录平台 TriNetX 分析了 1300 多万美国儿科患者的数据。对年龄小于18岁、接受过VA分流术的患者定义了两个匹配队列。第一组(n = 311)在 2020 年 3 月 1 日至 2022 年 3 月 31 日期间 COVID-19 实验室检测呈阳性。第 2 组(n = 311)为对照组,在 2020 年 3 月 1 日至 2022 年 3 月 31 日期间接受过任何医疗预约,且 COVID-19 实验室检测结果从未呈阳性。作者分析了第一组患者 COVID-19 检测呈阳性一年后的结果,以及第二组患者就诊后的结果。结果包括分流并发症、分流改造或更换以及血栓栓塞并发症。为保护患者隐私,TriNetX.Results中未列出少于10名患者的个体结果:第一组发生机械分流并发症的几率高于第二组(20% vs 4%,OR 5.71,95% CI 3.07-10.62)。第一组患者再次进行分流手术的几率高于第二组(11% vs < 3%,OR > 3.7,95% CI 1.72-7.62)。第1组有1-10名患者(≤第1组的3%)因分流术导致血栓栓塞,而第2组没有患者因分流术导致血栓栓塞:这项分析表明,COVID-19感染后,VA分流患者出现分流并发症、再次手术和血栓栓塞事件是有关联的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of neurosurgery. Pediatrics
Journal of neurosurgery. Pediatrics 医学-临床神经学
CiteScore
3.40
自引率
10.50%
发文量
307
审稿时长
2 months
期刊介绍: Information not localiced
期刊最新文献
Pediatric CSF diversion procedures for treatment of hydrocephalus during the COVID-19 pandemic. The impact of spheno-occipital synchondrosis exposure via extended endoscopic endonasal surgery on midface growth in pediatric patients. Association between social determinants of health and select neurosurgical procedures in the National Spina Bifida Patient Registry. Letter to the Editor. Sleep apnea and Chiari malformation type I. Predictors of postsurgical retethering in pediatric fatty or tight filum terminale: a systematic review and meta-analysis of 1167 patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1