Two Cases of Ischemic Optic Neuropathy after Extracorporeal Membrane Oxygenation (ECMO)

Kwang Eon Han, Sang Yoon Kim, Su Jin Kim
{"title":"Two Cases of Ischemic Optic Neuropathy after Extracorporeal Membrane Oxygenation (ECMO)","authors":"Kwang Eon Han, Sang Yoon Kim, Su Jin Kim","doi":"10.3341/jkos.2024.65.6.412","DOIUrl":null,"url":null,"abstract":"Purpose: We report two cases of non-arteritic ischemic optic neuropathy (NAION) following extracorporeal membrane oxygenation (ECMO) treatment.Case summary: (Case 1) A 36-year-old man underwent ECMO treatment. Upon regaining consciousness, he complained of a darkened peripheral visual field and was subsequently referred to an ophthalmologist. His best-corrected visual acuity was 0.9 in the right eye and 0.8 in the left eye. The intraocular pressure measured 12 mmHg in the right eye and 10 mmHg in the left eye; color vision was normal. A visual field test demonstrated concentric visual field defects in both eyes, and a fundus examination revealed a pale optic disc. Optical coherence tomography (OCT) indicated a decrease in retinal nerve fiber layer (RNFL) thickness. (Case 2) A 48-year-old woman underwent ECMO treatment. After regaining consciousness, she reported decreased vision in her right eye. Her best-corrected visual acuity was limited to hand motion in the right eye and was 1.2 in the left eye. A relative afferent pupillary defect in the right eye was observed. Color vision in the right eye was compromised, and a fundus examination revealed a pale optic disc. A visual field test demonstrated total visual field defect in the right eye, while OCT showed decreases in both the RNFL thickness and the ganglion cell-inner plexiform layer thickness of the right eye. Magnetic resonance imaging (MRI) revealed high signal intensity and abnormal enhancement in the right retrobulbar optic nerve.Conclusions: In cases where vision loss and visual field defects are observed following ECMO treatment, differential diagnoses for ischemic optic neuropathy are warranted.","PeriodicalId":17341,"journal":{"name":"Journal of The Korean Ophthalmological Society","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2024-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of The Korean Ophthalmological Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/jkos.2024.65.6.412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: We report two cases of non-arteritic ischemic optic neuropathy (NAION) following extracorporeal membrane oxygenation (ECMO) treatment.Case summary: (Case 1) A 36-year-old man underwent ECMO treatment. Upon regaining consciousness, he complained of a darkened peripheral visual field and was subsequently referred to an ophthalmologist. His best-corrected visual acuity was 0.9 in the right eye and 0.8 in the left eye. The intraocular pressure measured 12 mmHg in the right eye and 10 mmHg in the left eye; color vision was normal. A visual field test demonstrated concentric visual field defects in both eyes, and a fundus examination revealed a pale optic disc. Optical coherence tomography (OCT) indicated a decrease in retinal nerve fiber layer (RNFL) thickness. (Case 2) A 48-year-old woman underwent ECMO treatment. After regaining consciousness, she reported decreased vision in her right eye. Her best-corrected visual acuity was limited to hand motion in the right eye and was 1.2 in the left eye. A relative afferent pupillary defect in the right eye was observed. Color vision in the right eye was compromised, and a fundus examination revealed a pale optic disc. A visual field test demonstrated total visual field defect in the right eye, while OCT showed decreases in both the RNFL thickness and the ganglion cell-inner plexiform layer thickness of the right eye. Magnetic resonance imaging (MRI) revealed high signal intensity and abnormal enhancement in the right retrobulbar optic nerve.Conclusions: In cases where vision loss and visual field defects are observed following ECMO treatment, differential diagnoses for ischemic optic neuropathy are warranted.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两例体外膜氧合(ECMO)后缺血性视神经病变病例
目的:我们报告了两例体外膜肺氧合(ECMO)治疗后的非动脉缺血性视神经病变(NAION)病例。恢复意识后,他抱怨外周视野变暗,随后被转诊至眼科医生。他的右眼最佳矫正视力为 0.9,左眼为 0.8。右眼眼压为 12 毫米汞柱,左眼眼压为 10 毫米汞柱;色觉正常。视野测试显示双眼均有同心圆视野缺损,眼底检查显示视盘苍白。光学相干断层扫描(OCT)显示视网膜神经纤维层(RNFL)厚度下降。(病例 2)一名 48 岁女性接受了 ECMO 治疗。恢复意识后,她报告右眼视力下降。她的右眼最佳矫正视力仅限于手部运动,左眼为 1.2。右眼瞳孔相对传入缺损。右眼色觉受损,眼底检查发现视盘苍白。视野测试显示右眼完全视野缺损,而 OCT 显示右眼的 RNFL 厚度和神经节细胞-内丛状层厚度均有所下降。磁共振成像(MRI)显示右眼球后视神经信号强度高且异常增强:结论:在 ECMO 治疗后出现视力下降和视野缺损的病例中,需要鉴别诊断缺血性视神经病变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
126
期刊最新文献
Self-assessment of Visual Acuity Using a Smartphone Application The Diagnosis and Treatment of a Post-traumatic Iris Cyst Referred as an Iris Tumor Clinical Results of Prosthetic Eye Wear in Patients with Congenital Microphthalmos Two Cases of Ischemic Optic Neuropathy after Extracorporeal Membrane Oxygenation (ECMO) Injection Frequency and Differences in Visual Outcomes based on Diagnosis Year in Neovascular Age-related Macular Degeneration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1