A meta-analysis and cost-minimization analysis of cryoballoon ablation versus radiofrequency ablation for paroxysmal atrial fibrillation

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Arrhythmia Pub Date : 2024-06-09 DOI:10.1002/joa3.13055
Yoshimi Nitta MSPH, Michiko Nishimura MSc, Hidetoshi Shibahara PhD, Teiichi Yamane MD, PhD
{"title":"A meta-analysis and cost-minimization analysis of cryoballoon ablation versus radiofrequency ablation for paroxysmal atrial fibrillation","authors":"Yoshimi Nitta MSPH,&nbsp;Michiko Nishimura MSc,&nbsp;Hidetoshi Shibahara PhD,&nbsp;Teiichi Yamane MD, PhD","doi":"10.1002/joa3.13055","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>Previous studies have shown inconsistent results in clinical effectiveness between cryoballoon ablation (CBA) and radiofrequency ablation (RFA), and cost assessment between the procedures is important. The aim of this study was to evaluate the clinical effectiveness and cost-effectiveness between the procedures in patients with paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drug therapy.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A systematic review and meta-analysis were performed. The primary outcome for the meta-analysis was long-term AF recurrence. Following the results of the meta-analysis, the cost-effectiveness of CBA versus RFA in Japan was assessed.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>The meta-analysis included 12 randomized controlled trials and six propensity-score matching cohort studies. AF recurrence was slightly lower in patients referred for CBA than for RFA, with an integrated risk ratio of 0.93 (95% confidence interval: 0.81–1.07) and an integrated hazard ratio of 0.96 (95% confidence interval: 0.77–1.19), but no significant difference was found. A cost-minimization analysis was conducted to compare the medical costs of CBA versus RFA because there was no significant difference in the risk of AF recurrence between the procedures. The estimated costs for CBA and RFA were JPY 4 858 544 (USD 32 390) and JPY 4 505 255 (USD 30 035), respectively, with cost savings for RFA of JPY 353 289 (USD 2355).</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Our meta-analysis suggests that CBA provides comparable benefits with regard to AF recurrence compared with RFA, as shown in previous studies. Although the choice of treatment should be based on patient and treatment characteristics, RFA was shown that it might be cost saving as compared to CBA.</p>\n </section>\n </div>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 4","pages":"802-814"},"PeriodicalIF":2.2000,"publicationDate":"2024-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13055","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Previous studies have shown inconsistent results in clinical effectiveness between cryoballoon ablation (CBA) and radiofrequency ablation (RFA), and cost assessment between the procedures is important. The aim of this study was to evaluate the clinical effectiveness and cost-effectiveness between the procedures in patients with paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drug therapy.

Methods

A systematic review and meta-analysis were performed. The primary outcome for the meta-analysis was long-term AF recurrence. Following the results of the meta-analysis, the cost-effectiveness of CBA versus RFA in Japan was assessed.

Results

The meta-analysis included 12 randomized controlled trials and six propensity-score matching cohort studies. AF recurrence was slightly lower in patients referred for CBA than for RFA, with an integrated risk ratio of 0.93 (95% confidence interval: 0.81–1.07) and an integrated hazard ratio of 0.96 (95% confidence interval: 0.77–1.19), but no significant difference was found. A cost-minimization analysis was conducted to compare the medical costs of CBA versus RFA because there was no significant difference in the risk of AF recurrence between the procedures. The estimated costs for CBA and RFA were JPY 4 858 544 (USD 32 390) and JPY 4 505 255 (USD 30 035), respectively, with cost savings for RFA of JPY 353 289 (USD 2355).

Conclusion

Our meta-analysis suggests that CBA provides comparable benefits with regard to AF recurrence compared with RFA, as shown in previous studies. Although the choice of treatment should be based on patient and treatment characteristics, RFA was shown that it might be cost saving as compared to CBA.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
冷冻球囊消融术与射频消融术治疗阵发性心房颤动的荟萃分析和成本最小化分析
以往的研究表明,冷冻球囊消融术(CBA)和射频消融术(RFA)的临床疗效并不一致,因此对这两种手术的成本进行评估非常重要。本研究旨在评估抗心律失常药物治疗难治性阵发性心房颤动(房颤)患者的临床疗效和成本效益。荟萃分析的主要结果是房颤长期复发。荟萃分析包括 12 项随机对照试验和 6 项倾向分数匹配队列研究。接受 CBA 治疗的患者房颤复发率略低于接受 RFA 治疗的患者,综合风险比为 0.93(95% 置信区间:0.81-1.07),综合危险比为 0.96(95% 置信区间:0.77-1.19),但未发现显著差异。由于两种手术的房颤复发风险没有显著差异,因此进行了成本最小化分析,以比较 CBA 和 RFA 的医疗成本。CBA 和 RFA 的估计成本分别为 4 858 544 日元(32 390 美元)和 4 505 255 日元(30 035 美元),RFA 节省的成本为 353 289 日元(2355 美元)。尽管治疗方法的选择应基于患者和治疗特点,但与 CBA 相比,RFA 可节省费用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
期刊最新文献
Issue Information Dementia risk reduction between DOACs and VKAs in AF: A systematic review and meta-analysis Electro-anatomically confirmed sites of origin of ventricular tachycardia and premature ventricular contractions and occurrence of R wave in lead aVR: A proof of concept study The Japanese Catheter Ablation Registry (J-AB): Annual report in 2022 Slow left atrial conduction velocity in the anterior wall calculated by electroanatomic mapping predicts atrial fibrillation recurrence after catheter ablation—Systematic review and meta-analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1