Real-time display of intracranial subdural electrodes and the brain surface during an electrode implantation procedure using permeable film

So Fujimoto, Takeshi Matsuo, Yasuhiro Nakata, Honoka Shiojima
{"title":"Real-time display of intracranial subdural electrodes and the brain surface during an electrode implantation procedure using permeable film","authors":"So Fujimoto, Takeshi Matsuo, Yasuhiro Nakata, Honoka Shiojima","doi":"10.25259/sni_74_2024","DOIUrl":null,"url":null,"abstract":"\n\nSubdural electrode (SDE) implantation is an important method of diagnosing epileptogenic lesions and mapping brain function, even with the current preference for stereoelectroencephalography. We developed a novel method to assess SDEs and the brain surface during the electrode implantation procedure using brain images printed onto permeable films and intraoperative fluoroscopy. This method can help verify the location of the electrode during surgery and improve the accuracy of SDE implantation.\n\n\n\nWe performed preoperative imaging by magnetic resonance imaging and computed tomography. Subsequently, the images were edited and fused to visualize the gyrus and sulcus better. We printed the images on permeable films and superimposed them on the intraoperative fluoroscopy display. The intraoperative and postoperative coordinates of the electrodes were obtained after the implantation surgery, and the differences in the locations were calculated.\n\n\n\nPermeable films were created for a total of eight patients with intractable epilepsy. The median difference of the electrodes between the intraoperative and postoperative images was 4.6 mm (Interquartile range 2.9–7.1). The locations of electrodes implanted outside the operation field were not significantly different from those implanted inside.\n\n\n\nOur new method may guide the implantation of SDEs into their planned location.\n","PeriodicalId":38981,"journal":{"name":"Surgical Neurology International","volume":" 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Neurology International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/sni_74_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Subdural electrode (SDE) implantation is an important method of diagnosing epileptogenic lesions and mapping brain function, even with the current preference for stereoelectroencephalography. We developed a novel method to assess SDEs and the brain surface during the electrode implantation procedure using brain images printed onto permeable films and intraoperative fluoroscopy. This method can help verify the location of the electrode during surgery and improve the accuracy of SDE implantation. We performed preoperative imaging by magnetic resonance imaging and computed tomography. Subsequently, the images were edited and fused to visualize the gyrus and sulcus better. We printed the images on permeable films and superimposed them on the intraoperative fluoroscopy display. The intraoperative and postoperative coordinates of the electrodes were obtained after the implantation surgery, and the differences in the locations were calculated. Permeable films were created for a total of eight patients with intractable epilepsy. The median difference of the electrodes between the intraoperative and postoperative images was 4.6 mm (Interquartile range 2.9–7.1). The locations of electrodes implanted outside the operation field were not significantly different from those implanted inside. Our new method may guide the implantation of SDEs into their planned location.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在使用渗透膜进行电极植入过程中实时显示颅内硬膜下电极和脑表面的情况
硬膜下电极(SDE)植入术是诊断致痫病灶和绘制大脑功能图的重要方法,即使目前更倾向于使用立体脑电图。我们开发了一种新方法,可在电极植入过程中使用印在可渗透薄膜上的脑图像和术中透视来评估 SDE 和脑表面。我们在术前通过磁共振成像和计算机断层扫描进行了成像。随后,我们对图像进行了编辑和融合,以便更好地观察脑回和脑沟。我们将图像打印在透视胶片上,并将其叠加到术中透视显示屏上。植入手术后,我们获得了术中和术后电极的坐标,并计算了位置差异。术中和术后图像中电极位置差异的中位数为 4.6 毫米(四分位距为 2.9-7.1 毫米)。植入手术区域外的电极位置与植入手术区域内的电极位置没有明显差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.30
自引率
0.00%
发文量
623
期刊最新文献
Cauda equina syndrome due to posttraumatic syringomyelia in conus medullaris – A case report Patients with meningioma hemorrhage should undergo an autopsy if they die from it despite successful surgery Expanded endoscopic endonasal approach for resection of residual parasellar growth hormone-secreting pituitary adenoma in a patient with kissing internal carotid arteries: Technical nuances Microsurgery resection of giant cervicothoracic spinal ependymoma: Two-dimensional operative video Non-granulomatous meningoencephalitis with Balamuthia mandrillaris mimicking a tumor: First confirmed case from Pakistan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1