Loss of energetic particles due to feedback control of resistive wall mode in HL-3

Yifei Zhao, Yueqiang Liu, Guangzhou Hao, Zhengxiong Wang, Guanqi Dong, Shuo Wang, Chunyu Li, Guanming Yang, Y. Miao, Yongqin Wang
{"title":"Loss of energetic particles due to feedback control of resistive wall mode in HL-3","authors":"Yifei Zhao, Yueqiang Liu, Guangzhou Hao, Zhengxiong Wang, Guanqi Dong, Shuo Wang, Chunyu Li, Guanming Yang, Y. Miao, Yongqin Wang","doi":"10.1088/2058-6272/ad547e","DOIUrl":null,"url":null,"abstract":"\n Effects of three-dimensional (3D) magnetic field perturbations due to feedback control of an unstable n = 1 (n is toroidal mode number) resistive wall mode (RWM) on the energetic particle (EP) losses are systematically investigated for the HL-3 tokamak. The MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) code, facilitated by the test particle guiding center tracing module REORBIT, is utilized for the study. The RWM is found to generally produce no EP loss for co-current particles in HL-3. Assuming the same perturbation level at the sensor location for the close-loop system, feedback produces nearly the same loss of counter-current EPs compared to the open-loop case. Assuming however that the sensor signal is ten times smaller in the close-loop system than the open-loop counter part (reflecting the fact that the RWM is more stable with feedback), the counter-current EP loss is found significantly reduced in the former. Most of EP losses occur only for particles launched close to the plasma edge, while particles launched further away from the plasma boundary experience much less loss. The strike points of lost EPs on the HL-3 limiting surface become more scattered for particles launched closer to the plasma boundary. Taking into account the full gyro-orbit of particles while approaching the limiting surface, REORBIT finds slightly enhanced loss fraction.","PeriodicalId":506986,"journal":{"name":"Plasma Science and Technology","volume":"28 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2058-6272/ad547e","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Effects of three-dimensional (3D) magnetic field perturbations due to feedback control of an unstable n = 1 (n is toroidal mode number) resistive wall mode (RWM) on the energetic particle (EP) losses are systematically investigated for the HL-3 tokamak. The MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) code, facilitated by the test particle guiding center tracing module REORBIT, is utilized for the study. The RWM is found to generally produce no EP loss for co-current particles in HL-3. Assuming the same perturbation level at the sensor location for the close-loop system, feedback produces nearly the same loss of counter-current EPs compared to the open-loop case. Assuming however that the sensor signal is ten times smaller in the close-loop system than the open-loop counter part (reflecting the fact that the RWM is more stable with feedback), the counter-current EP loss is found significantly reduced in the former. Most of EP losses occur only for particles launched close to the plasma edge, while particles launched further away from the plasma boundary experience much less loss. The strike points of lost EPs on the HL-3 limiting surface become more scattered for particles launched closer to the plasma boundary. Taking into account the full gyro-orbit of particles while approaching the limiting surface, REORBIT finds slightly enhanced loss fraction.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
HL-3 中电阻壁模式的反馈控制导致的高能粒子损失
系统地研究了 HL-3 托卡马克不稳定 n = 1(n 为环模数)电阻壁模(RWM)反馈控制引起的三维(3D)磁场扰动对高能粒子(EP)损耗的影响。研究使用了 MARS-F(Liu 等,2000 年,Phys. Plasmas 7 3681)代码,该代码由测试粒子导向中心跟踪模块 REORBIT 提供支持。研究发现,RWM 通常不会对 HL-3 中的同流粒子产生 EP 损失。假设闭环系统传感器位置的扰动水平相同,反馈产生的逆流 EP 损失与开环情况几乎相同。然而,假设闭环系统中的传感器信号比开环系统小十倍(这反映了在反馈情况下 RWM 更加稳定的事实),则前者的逆流 EP 损失会显著减少。大部分 EP 损失只发生在靠近等离子体边缘发射的粒子上,而发射到远离等离子体边界的粒子上的 EP 损失要少得多。对于发射到靠近等离子体边界的粒子,HL-3 极限表面上损失的 EP 的撞击点变得更加分散。考虑到粒子在接近极限表面时的整个陀螺轨道,REORBIT 发现损失部分略有增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Integrated design and performance optimization of three-electrode sliding discharge plasma power supply Simulation of tungsten impurity transport by DIVIMP under different divertor magnetic configurations on HL-3 Characteristics of divertor heat flux distribution with an island divertor configuration on the J-TEXT tokamak Synthesis of NO by rotating sliding arc discharge reactor with conical-spiral electrodes Analyses of non-equilibrium transports in atmospheric-pressure direct-current argon discharges under different modes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1