{"title":"Comparative Analysis of Recurrent Glioblastoma Target Contours via 11C-Methionine, 68Ga-Prostate-Specific Membrane Antigen Positron Emission Tomography, and Magnetic Resonance Imaging: Implications for Precision Radiotherapy Planning","authors":"","doi":"10.1016/j.adro.2024.101548","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>Glioblastoma (GBM) recurrence poses challenges in radiation therapy treatment planning because reirradiation has limited leeway needed for precise target delineation. Although effective radiotracers are emerging for treatment planning, comparisons of <sup>11</sup>C-methionine positron emission tomography (MET-PET), <sup>68</sup>Ga-prostate-specific membrane antigen PET (PSMA-PET), and magnetic resonance imaging (MRI) for contouring recurrent GBMs are lacking in the literature. This case study aimed to highlight the differences and similarities in target contours delineated from 3 examinations, aiming to raise doubts about the adequacy of current radiation therapy planning practices.</p></div><div><h3>Methods and Materials</h3><p>A 37-year-old female patient with recurrent Isocitrate dehydrogenase (IDH)1/2 wild-type GBM underwent MRI, MET-PET, and PSMA-PET scans. Target delineations were performed, and volumes were compared using the Dice similarity coefficient, conformity index, and overlap volume, considering different planning target volume margins.</p></div><div><h3>Results</h3><p>We found that MET-PET and MRI volumes showed superior agreement compared with PSMA-PET across all similarity parameters, indicating a more marked discrepancy between PSMA-PET and other modalities. Increasing planning target volume margins demonstrated progressive convergence in intervolume discrepancies. Notably, PSMA-PET delineated larger volumes extending beyond MRI-based volumes.</p></div><div><h3>Conclusions</h3><p>MRI alone may not suffice for target delineation in recurrent GBMs. PET imaging modalities offer complementary insights. Combined PET-MRI guidance could improve tumor boundary detection in target delineation for reirradiation. Prospective trials are necessary to ascertain its impact on patient outcomes.</p></div>","PeriodicalId":7390,"journal":{"name":"Advances in Radiation Oncology","volume":"9 9","pages":"Article 101548"},"PeriodicalIF":2.2000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2452109424001118/pdfft?md5=ddbb8f70ebb7616e5acf4ccd15fdc898&pid=1-s2.0-S2452109424001118-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Radiation Oncology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2452109424001118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Glioblastoma (GBM) recurrence poses challenges in radiation therapy treatment planning because reirradiation has limited leeway needed for precise target delineation. Although effective radiotracers are emerging for treatment planning, comparisons of 11C-methionine positron emission tomography (MET-PET), 68Ga-prostate-specific membrane antigen PET (PSMA-PET), and magnetic resonance imaging (MRI) for contouring recurrent GBMs are lacking in the literature. This case study aimed to highlight the differences and similarities in target contours delineated from 3 examinations, aiming to raise doubts about the adequacy of current radiation therapy planning practices.

Methods and Materials

A 37-year-old female patient with recurrent Isocitrate dehydrogenase (IDH)1/2 wild-type GBM underwent MRI, MET-PET, and PSMA-PET scans. Target delineations were performed, and volumes were compared using the Dice similarity coefficient, conformity index, and overlap volume, considering different planning target volume margins.

Results

We found that MET-PET and MRI volumes showed superior agreement compared with PSMA-PET across all similarity parameters, indicating a more marked discrepancy between PSMA-PET and other modalities. Increasing planning target volume margins demonstrated progressive convergence in intervolume discrepancies. Notably, PSMA-PET delineated larger volumes extending beyond MRI-based volumes.

Conclusions

MRI alone may not suffice for target delineation in recurrent GBMs. PET imaging modalities offer complementary insights. Combined PET-MRI guidance could improve tumor boundary detection in target delineation for reirradiation. Prospective trials are necessary to ascertain its impact on patient outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过11C-蛋氨酸、68 Ga-PSMA PET成像和磁共振成像对比分析复发性胶质母细胞瘤靶区轮廓:对精准放疗规划的启示
目的胶质母细胞瘤(GBM)复发给放疗治疗计划带来了挑战,因为再照射的余地有限,无法精确划分靶区。虽然有效的放射性核素在治疗计划中不断涌现,但文献中缺乏对 11C-蛋氨酸正电子发射断层扫描(MET-PET)、68Ga-前列腺特异性膜抗原正电子发射断层扫描(PSMA-PET)和磁共振成像(MRI)用于复发 GBM 轮廓的比较。本病例研究旨在强调 3 种检查所划定的靶点轮廓的异同,从而引起人们对目前放射治疗计划实践是否充分的质疑。方法和材料一名 37 岁的复发性异柠檬酸脱氢酶(IDH)1/2 野生型 GBM 女性患者接受了 MRI、MET-PET 和 PSMA-PET 扫描。结果我们发现,与 PSMA-PET 相比,MET-PET 和 MRI 容量在所有相似性参数上都表现出更高的一致性,这表明 PSMA-PET 与其他模式之间存在更明显的差异。规划目标容积边缘的增加表明容积间差异逐渐趋同。值得注意的是,PSMA-PET划定的体积超出了基于核磁共振成像的体积。PET成像模式提供了补充性见解。PET-MRI联合引导可改善再照射靶区划分中的肿瘤边界检测。有必要进行前瞻性试验,以确定其对患者预后的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Advances in Radiation Oncology
Advances in Radiation Oncology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.60
自引率
4.30%
发文量
208
审稿时长
98 days
期刊介绍: The purpose of Advances is to provide information for clinicians who use radiation therapy by publishing: Clinical trial reports and reanalyses. Basic science original reports. Manuscripts examining health services research, comparative and cost effectiveness research, and systematic reviews. Case reports documenting unusual problems and solutions. High quality multi and single institutional series, as well as other novel retrospective hypothesis generating series. Timely critical reviews on important topics in radiation oncology, such as side effects. Articles reporting the natural history of disease and patterns of failure, particularly as they relate to treatment volume delineation. Articles on safety and quality in radiation therapy. Essays on clinical experience. Articles on practice transformation in radiation oncology, in particular: Aspects of health policy that may impact the future practice of radiation oncology. How information technology, such as data analytics and systems innovations, will change radiation oncology practice. Articles on imaging as they relate to radiation therapy treatment.
期刊最新文献
Outcomes After Stereotactic Body Radiation for Hepatocellular Carcinoma in Patients With Child-Pugh A Versus Child-Pugh B/C Cirrhosis Editorial board Pegylated Interferon Combined With Low-Dose Total Skin Electron Beam Therapy for Advanced Stage Mycosis Fungoides: Two Case Reports and Literature Review Cone Beam Computed Tomography-Based Online Adaptive Radiation Therapy of Esophageal Cancer: First Clinical Experience and Dosimetric Benefits Prospective Trial on the Impact of Weekly Cone Beam Computed Tomography-Guided Correction on Mean Heart Dose in Breast Cancer Breath-Hold Radiation Therapy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1