Successful treatment of a recalcitrant nonunion after periprosthetic femoral fracture using a cementless long stem with interlocking screws inserted via a locking plate: A case report

Masashi Sato, Hisatoshi Ishikura , Naoto Kaminaga, Takeyuki Tanaka, Sakae Tanaka
{"title":"Successful treatment of a recalcitrant nonunion after periprosthetic femoral fracture using a cementless long stem with interlocking screws inserted via a locking plate: A case report","authors":"Masashi Sato,&nbsp;Hisatoshi Ishikura ,&nbsp;Naoto Kaminaga,&nbsp;Takeyuki Tanaka,&nbsp;Sakae Tanaka","doi":"10.1016/j.joscr.2024.05.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Nonunion after periprosthetic femoral fracture is a recalcitrant challenge for hip surgeons.</div></div><div><h3>Case presentation</h3><div>A 55-year-old man underwent hemiarthroplasty for right femoral head osteonecrosis at another hospital. Two weeks after surgery, he developed a periprosthetic femoral fracture. He was referred to our hospital because of nonunion of the fracture site even after five surgeries. Surgery was performed using a cementless long stem combined with a locking plate. Three locking screws were passed through the distal holes of the stem to improve fixation. Bone union was achieved, and he was able to walk six months after surgery.</div></div><div><h3>Conclusions</h3><div>A cementless long stem with interlocking screws inserted via a locking plate offers rigid stability and bone union. Our report is relevant because it highlights a surgical option for recalcitrant nonunion after periprosthetic femoral fractures.</div></div>","PeriodicalId":100743,"journal":{"name":"JOS Case Reports","volume":"3 4","pages":"Pages 196-200"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JOS Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772964824000224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Nonunion after periprosthetic femoral fracture is a recalcitrant challenge for hip surgeons.

Case presentation

A 55-year-old man underwent hemiarthroplasty for right femoral head osteonecrosis at another hospital. Two weeks after surgery, he developed a periprosthetic femoral fracture. He was referred to our hospital because of nonunion of the fracture site even after five surgeries. Surgery was performed using a cementless long stem combined with a locking plate. Three locking screws were passed through the distal holes of the stem to improve fixation. Bone union was achieved, and he was able to walk six months after surgery.

Conclusions

A cementless long stem with interlocking screws inserted via a locking plate offers rigid stability and bone union. Our report is relevant because it highlights a surgical option for recalcitrant nonunion after periprosthetic femoral fractures.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用无骨水泥长柄和通过锁定板插入的联锁螺钉成功治疗股骨假体周围骨折后的顽固性不愈合:病例报告
背景:股骨假体周围骨折后骨不连是髋关节外科医生面临的难题。一例55岁男性因右股骨头坏死在另一家医院行半关节置换术。手术后两周,他发生了股骨假体周围骨折。他被转介到我们医院,因为骨折部位不愈合,甚至在五次手术后。手术采用无骨水泥长柄结合锁定钢板。将三枚锁定螺钉穿过柄的远端孔以改善固定。手术后6个月,他就能走路了。结论无骨水泥长柄经锁定钢板置入联锁螺钉,具有良好的骨稳定性和骨愈合。我们的报告是相关的,因为它强调了手术治疗股骨假体周围骨折后顽固性骨不连的选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tibial-hindfoot turn-up plasty following proximal femur and periacetabular resection for unplanned sarcoma resection: A case report Achilles tendon rupture in previously treated clubfoot: Is there a correlation? A pediatric case report and a literature review Urethral injury secondary to advanced fragility fracture of the pelvis: A case report Sequential multimodal management of methicillin-resistant Staphylococcus aureus-infected tibial pseudoarthrosis: A case report on the application of an antibiotic-loaded cement spacer and the continuous local antibiotic perfusion technique across three stages A case of Aitken Classification Type A proximal femoral focal deficiency treated with plate fixation for pseudarthrosis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1