Virtual reconstruction of orbital defects using Gaussian process morphable models.

IF 2.3 3区 医学 Q3 ENGINEERING, BIOMEDICAL International Journal of Computer Assisted Radiology and Surgery Pub Date : 2024-09-01 Epub Date: 2024-06-19 DOI:10.1007/s11548-024-03200-4
Pieter Vanslambrouck, Jeroen Van Dessel, Constantinus Politis, Robin Willaert, Michel Bila, Yi Sun, Peter Claes
{"title":"Virtual reconstruction of orbital defects using Gaussian process morphable models.","authors":"Pieter Vanslambrouck, Jeroen Van Dessel, Constantinus Politis, Robin Willaert, Michel Bila, Yi Sun, Peter Claes","doi":"10.1007/s11548-024-03200-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The conventional method to reconstruct the bone level for orbital defects, which is based on mirroring and manual adaptation, is time-consuming and the accuracy highly depends on the expertise of the clinical engineer. The aim of this study is to propose and evaluate an automated reconstruction method utilizing a Gaussian process morphable model (GPMM).</p><p><strong>Methods: </strong>Sixty-five Computed Tomography (CT) scans of healthy midfaces were used to create a GPMM that can model shape variations of the orbital region. Parameter optimization was performed by evaluating several quantitative metrics inspired on the shape modeling literature, e.g. generalization and specificity. The reconstruction error was estimated by reconstructing artificial defects created in orbits from fifteen CT scans that were not included in the GPMM. The developed algorithms utilize the existing framework of Gaussian process morphable models, as implemented in the Scalismo software.</p><p><strong>Results: </strong>By evaluating the proposed quality metrics, adequate parameters are chosen for non-rigid registration and reconstruction. The resulting median reconstruction error using the GPMM was lower (0.35 ± 0.16 mm) compared to the mirroring method (0.52 ± 0.18 mm). In addition, the GPMM-based reconstruction is automated and can be applied to large bilateral defects with a median reconstruction error of 0.39 ± 0.11 mm.</p><p><strong>Conclusion: </strong>The GPMM-based reconstruction proves to be less time-consuming and more accurate than reconstruction by mirroring. Further validation through clinical studies on patients with orbital defects is warranted. Nevertheless, the results underscore the potential of GPMM-based reconstruction as a promising alternative for designing patient-specific implants.</p>","PeriodicalId":51251,"journal":{"name":"International Journal of Computer Assisted Radiology and Surgery","volume":" ","pages":"1909-1917"},"PeriodicalIF":2.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Computer Assisted Radiology and Surgery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11548-024-03200-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/19 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The conventional method to reconstruct the bone level for orbital defects, which is based on mirroring and manual adaptation, is time-consuming and the accuracy highly depends on the expertise of the clinical engineer. The aim of this study is to propose and evaluate an automated reconstruction method utilizing a Gaussian process morphable model (GPMM).

Methods: Sixty-five Computed Tomography (CT) scans of healthy midfaces were used to create a GPMM that can model shape variations of the orbital region. Parameter optimization was performed by evaluating several quantitative metrics inspired on the shape modeling literature, e.g. generalization and specificity. The reconstruction error was estimated by reconstructing artificial defects created in orbits from fifteen CT scans that were not included in the GPMM. The developed algorithms utilize the existing framework of Gaussian process morphable models, as implemented in the Scalismo software.

Results: By evaluating the proposed quality metrics, adequate parameters are chosen for non-rigid registration and reconstruction. The resulting median reconstruction error using the GPMM was lower (0.35 ± 0.16 mm) compared to the mirroring method (0.52 ± 0.18 mm). In addition, the GPMM-based reconstruction is automated and can be applied to large bilateral defects with a median reconstruction error of 0.39 ± 0.11 mm.

Conclusion: The GPMM-based reconstruction proves to be less time-consuming and more accurate than reconstruction by mirroring. Further validation through clinical studies on patients with orbital defects is warranted. Nevertheless, the results underscore the potential of GPMM-based reconstruction as a promising alternative for designing patient-specific implants.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用高斯过程可变形模型虚拟重建轨道缺陷。
目的:重建眼眶缺损骨水平的传统方法基于镜像和手动适应,耗时长,准确性高度依赖于临床工程师的专业知识。本研究旨在提出并评估一种利用高斯过程可变形模型(GPMM)的自动重建方法:方法:使用 65 张健康中面部的计算机断层扫描 (CT) 扫描图像创建一个可模拟眼眶区域形状变化的 GPMM。通过评估形状建模文献中的几个定量指标,如概括性和特异性,对参数进行了优化。重建误差是通过重建未包含在 GPMM 中的 15 个 CT 扫描中的轨道人工缺陷来估算的。开发的算法利用了 Scalismo 软件中现有的高斯过程可变形模型框架:结果:通过评估所提出的质量指标,为非刚性配准和重建选择了适当的参数。与镜像法(0.52 ± 0.18 毫米)相比,使用 GPMM 得出的重建误差中值更低(0.35 ± 0.16 毫米)。此外,基于 GPMM 的重建是自动化的,可用于双侧大面积缺损,重建误差中值为 0.39 ± 0.11 毫米:结论:与镜像重建相比,基于 GPMM 的重建耗时更短,精度更高。结论:事实证明,基于 GPMM 的重建比镜像重建更省时、更准确,还需要通过对眼眶缺损患者的临床研究进一步验证。尽管如此,这些结果还是凸显了基于 GPMM 的重建作为设计患者特异性植入物的替代方法的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Computer Assisted Radiology and Surgery
International Journal of Computer Assisted Radiology and Surgery ENGINEERING, BIOMEDICAL-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
5.90
自引率
6.70%
发文量
243
审稿时长
6-12 weeks
期刊介绍: The International Journal for Computer Assisted Radiology and Surgery (IJCARS) is a peer-reviewed journal that provides a platform for closing the gap between medical and technical disciplines, and encourages interdisciplinary research and development activities in an international environment.
期刊最新文献
Navigated hepatic tumor resection using intraoperative ultrasound imaging. CVS assessment via distillation-based self-supervised and multiple instance learning in laparoscopic cholecystectomy. Development of a wire-driven film-type device for tissue elimination in rectal cancer endoscopic surgery. A hybrid self-supervised teacher-student model for predicting neurovascular bundle preservation in prostatectomy videos. ProstNFound+: A Prospective Study using Medical Foundation Models for Prostate Cancer Detection.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1