Seismic response characteristics of seismically isolated buildings with dead zone mechanism connected to oil damper

IF 0.8 0 ARCHITECTURE Japan Architectural Review Pub Date : 2024-06-17 DOI:10.1002/2475-8876.12448
Kazuo Yachiune, Akira Suzuki, Yuta Saito, Masaki Tokuno, Masahito Kobayashi
{"title":"Seismic response characteristics of seismically isolated buildings with dead zone mechanism connected to oil damper","authors":"Kazuo Yachiune,&nbsp;Akira Suzuki,&nbsp;Yuta Saito,&nbsp;Masaki Tokuno,&nbsp;Masahito Kobayashi","doi":"10.1002/2475-8876.12448","DOIUrl":null,"url":null,"abstract":"<p>In recent years, there has been concern about the occurrence of extreme ground motions that greatly exceed the amplitude levels and durations expected at the conventional design level. Therefore, seismically isolated buildings are required to ensure seismic isolation performance for small earthquakes and suppress the excessive displacement of the seismic isolation layer for extreme ground motions. In this paper, we analyze the seismic response of seismically isolated buildings with the dead zone mechanism connected to oil dampers to understand the response characteristics.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"7 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12448","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
引用次数: 0

Abstract

In recent years, there has been concern about the occurrence of extreme ground motions that greatly exceed the amplitude levels and durations expected at the conventional design level. Therefore, seismically isolated buildings are required to ensure seismic isolation performance for small earthquakes and suppress the excessive displacement of the seismic isolation layer for extreme ground motions. In this paper, we analyze the seismic response of seismically isolated buildings with the dead zone mechanism connected to oil dampers to understand the response characteristics.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用与油阻尼器相连的死区机构的隔震建筑物的地震响应特性
近年来,人们对极端地面运动的发生表示担忧,这些运动的振幅水平和持续时间大大超出了常规设计水平的预期。因此,需要采用隔震建筑来确保小震时的隔震性能,并抑制极端地面运动时隔震层的过大位移。本文分析了与油阻尼器连接的死区机构的隔震建筑物的地震响应,以了解其响应特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.20
自引率
11.10%
发文量
58
审稿时长
15 weeks
期刊最新文献
Investigation of indoor microplastics in settled indoor house dust in single-person residential buildings in Japan An investigation of the effect of vibration duration on the evaluation of subjective responses to horizontal vibration Design process of the Memorial Cathedral for World Peace (1954), Hiroshima, by Togo Murano (Part 4): Formal manipulations observed in the process of working design and construction instruction of the cathedral (1948–1954) Communication behavior and space utilization of office workers in a research facility's activity-based workplace A new processing method of ground acceleration data for fast and accurate evaluation of maximum seismic structural response
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1