Easy recognition and high autoimmune hepatitis specificity of smooth muscle antibodies giving an actin microfilament immunofluorescent pattern on embryonal vascular smooth muscle cells.
Alessandro Granito, Paolo Muratori, Georgios Pappas, Marco Lenzi, Albert J Czaja, Luigi Muratori
{"title":"Easy recognition and high autoimmune hepatitis specificity of smooth muscle antibodies giving an actin microfilament immunofluorescent pattern on embryonal vascular smooth muscle cells.","authors":"Alessandro Granito, Paolo Muratori, Georgios Pappas, Marco Lenzi, Albert J Czaja, Luigi Muratori","doi":"10.1093/cei/uxae051","DOIUrl":null,"url":null,"abstract":"<p><p>Smooth muscle antibodies (SMA) with anti-microfilament actin (MF-SMA) specificity are regarded as highly specific markers of type 1 autoimmune hepatitis (AIH-1) but their recognition relying on immunofluorescence of vessel, glomeruli, and tubules (SMA-VGT pattern) in rodent kidney tissue, is restricted by operator-dependent interpretation. A gold standard method for their identification is not available. We assessed and compared the diagnostic accuracy for AIH-1 of an embryonal aorta vascular smooth muscle (VSM) cell line-based assay with those of the rodent tissue-based assay for the detection of MF-SMA pattern in AIH-1 patients and controls. Sera from 138 AIH-1 patients and 295 controls (105 primary biliary cholangitis, 40 primary sclerosing cholangitis, 50 chronic viral hepatitis, 20 alcohol-related liver disease, 40 steatotic liver disease, and 40 healthy controls) were assayed for MF-SMA and SMA-VGT using VSM-based and rodent tissue-based assays, respectively. MF-SMA and SMA-VGT were found in 96 (70%) and 87 (63%) AIH-1 patients, and 2 controls (P < 0.0001). Compared with SMA-VGT, MF-SMA showed similar specificity (99%), higher sensitivity (70% vs 63%, P = ns) and likelihood ratio for a positive test (70 vs 65). Nine (7%) AIH-1 patients were MF-SMA positive despite being SMA-VGT negative. Overall agreement between SMA-VGT and MF-SMA was 87% (kappa coefficient 0.870, [0.789-0.952]). MF-SMA were associated with higher serum γ-globulin [26 (12-55) vs 20 g/l (13-34), P < 0.005] and immunoglobulin G (IgG) levels [3155 (1296-7344) vs 2050 mg/dl (1377-3357), P < 0.002]. The easily recognizable IFL MF-SMA pattern on VSM cells strongly correlated with SMA-VGT and has an equally high specificity for AIH-1. Confirmation of these results in other laboratories would support the clinical application of the VSM cell-based assay for reliable detection of AIH-specific SMA.</p>","PeriodicalId":10268,"journal":{"name":"Clinical and experimental immunology","volume":" ","pages":"233-239"},"PeriodicalIF":3.4000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11310692/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and experimental immunology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/cei/uxae051","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Smooth muscle antibodies (SMA) with anti-microfilament actin (MF-SMA) specificity are regarded as highly specific markers of type 1 autoimmune hepatitis (AIH-1) but their recognition relying on immunofluorescence of vessel, glomeruli, and tubules (SMA-VGT pattern) in rodent kidney tissue, is restricted by operator-dependent interpretation. A gold standard method for their identification is not available. We assessed and compared the diagnostic accuracy for AIH-1 of an embryonal aorta vascular smooth muscle (VSM) cell line-based assay with those of the rodent tissue-based assay for the detection of MF-SMA pattern in AIH-1 patients and controls. Sera from 138 AIH-1 patients and 295 controls (105 primary biliary cholangitis, 40 primary sclerosing cholangitis, 50 chronic viral hepatitis, 20 alcohol-related liver disease, 40 steatotic liver disease, and 40 healthy controls) were assayed for MF-SMA and SMA-VGT using VSM-based and rodent tissue-based assays, respectively. MF-SMA and SMA-VGT were found in 96 (70%) and 87 (63%) AIH-1 patients, and 2 controls (P < 0.0001). Compared with SMA-VGT, MF-SMA showed similar specificity (99%), higher sensitivity (70% vs 63%, P = ns) and likelihood ratio for a positive test (70 vs 65). Nine (7%) AIH-1 patients were MF-SMA positive despite being SMA-VGT negative. Overall agreement between SMA-VGT and MF-SMA was 87% (kappa coefficient 0.870, [0.789-0.952]). MF-SMA were associated with higher serum γ-globulin [26 (12-55) vs 20 g/l (13-34), P < 0.005] and immunoglobulin G (IgG) levels [3155 (1296-7344) vs 2050 mg/dl (1377-3357), P < 0.002]. The easily recognizable IFL MF-SMA pattern on VSM cells strongly correlated with SMA-VGT and has an equally high specificity for AIH-1. Confirmation of these results in other laboratories would support the clinical application of the VSM cell-based assay for reliable detection of AIH-specific SMA.
期刊介绍:
Clinical & Experimental Immunology (established in 1966) is an authoritative international journal publishing high-quality research studies in translational and clinical immunology that have the potential to transform our understanding of the immunopathology of human disease and/or change clinical practice.
The journal is focused on translational and clinical immunology and is among the foremost journals in this field, attracting high-quality papers from across the world. Translation is viewed as a process of applying ideas, insights and discoveries generated through scientific studies to the treatment, prevention or diagnosis of human disease. Clinical immunology has evolved as a field to encompass the application of state-of-the-art technologies such as next-generation sequencing, metagenomics and high-dimensional phenotyping to understand mechanisms that govern the outcomes of clinical trials.