{"title":"Ultrasound-guided breast-conserving surgery compared to conventional breast-conserving surgery.","authors":"Bettina Boeer, Jennifer Obermoser, Mario Marx, Birgitt Schönfisch, Marcel Grube, Carmen Röhm, Gisela Helms, Regina Fugunt, Andreas D Hartkopf, Sara Y Brucker, Markus Hahn","doi":"10.1055/a-2290-1543","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The goal of breast-conserving surgery is to achieve negative tumor margins, since insufficient marginal distance is associated with more local and distant recurrences. This study investigates whether IOUS (intraoperative ultrasound) can reduce the re-resection rate compared to standard breast surgery, regardless of tumor biology and focality.</p><p><strong>Materials and methods: </strong>The present study is a monocentric, prospective, randomized, and non-blinded parallel group study conducted between 7/2015 and 2/2018. Patients with sonographically visible breast cancer were randomized into two study arms: 1) breast-conserving surgery with IOUS; 2) conventional arm.</p><p><strong>Results: </strong>364 patients were included in the study and underwent surgery. Tumor biology, size, and focality were equally distributed in both groups (p = 0.497). The study arms did not differ significantly in the proportion of preoperative wire markings (p= 0.084), specimen weight (p = 0.225), surgery duration (p = 0.849), and the proportion of shavings taken intraoperatively (p = 0.903). Positive margins were present in 16.6% of the cases in the IOUS arm and in 20.8% in the conventional arm (p = 0.347). Re-operation was necessary after intraoperative shavings in 14.4% of cases in the US arm and in 21.3% in the conventional arm (p = 0.100).</p><p><strong>Conclusion: </strong>Although the present study showed a clear difference in the rate of positive tumor margins with IOUS compared to conventional breast surgery without IOUS, this was not statistically significant in contrast to the current literature. This could be due to the high expertise of the breast surgeons, the precise wire marking, or the fact that the IOUS technique was not standardized.</p>","PeriodicalId":49400,"journal":{"name":"Ultraschall in Der Medizin","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultraschall in Der Medizin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2290-1543","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The goal of breast-conserving surgery is to achieve negative tumor margins, since insufficient marginal distance is associated with more local and distant recurrences. This study investigates whether IOUS (intraoperative ultrasound) can reduce the re-resection rate compared to standard breast surgery, regardless of tumor biology and focality.

Materials and methods: The present study is a monocentric, prospective, randomized, and non-blinded parallel group study conducted between 7/2015 and 2/2018. Patients with sonographically visible breast cancer were randomized into two study arms: 1) breast-conserving surgery with IOUS; 2) conventional arm.

Results: 364 patients were included in the study and underwent surgery. Tumor biology, size, and focality were equally distributed in both groups (p = 0.497). The study arms did not differ significantly in the proportion of preoperative wire markings (p= 0.084), specimen weight (p = 0.225), surgery duration (p = 0.849), and the proportion of shavings taken intraoperatively (p = 0.903). Positive margins were present in 16.6% of the cases in the IOUS arm and in 20.8% in the conventional arm (p = 0.347). Re-operation was necessary after intraoperative shavings in 14.4% of cases in the US arm and in 21.3% in the conventional arm (p = 0.100).

Conclusion: Although the present study showed a clear difference in the rate of positive tumor margins with IOUS compared to conventional breast surgery without IOUS, this was not statistically significant in contrast to the current literature. This could be due to the high expertise of the breast surgeons, the precise wire marking, or the fact that the IOUS technique was not standardized.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声引导下的保乳手术与传统保乳手术的比较。
目的:保乳手术的目标是实现肿瘤边缘阴性,因为边缘距离不足与更多的局部和远处复发有关。本研究探讨了与标准乳腺手术相比,IOUS(术中超声)是否能降低再切除率,而与肿瘤生物学特性和病灶无关:本研究是一项单中心、前瞻性、随机、非盲平行组研究,于 2015 年 7 月至 2018 年 2 月进行。声像图可见乳腺癌患者被随机分为两个研究组:1)IOUS保乳手术组;2)常规组:结果:364 名患者参与研究并接受了手术。两组患者的肿瘤生物学特性、大小和病灶分布相当(P = 0.497)。两组患者在术前金属丝标记比例(p= 0.084)、标本重量(p= 0.225)、手术时间(p= 0.849)和术中刨片比例(p= 0.903)方面无明显差异。IOUS手术组16.6%的病例边缘呈阳性,传统手术组20.8%的病例边缘呈阳性(p = 0.347)。在术中刨切后需要再次手术的病例中,美式手术组为 14.4%,而传统手术组为 21.3%(p = 0.100):尽管本研究显示,与不使用IOUS的传统乳腺手术相比,使用IOUS的肿瘤边缘阳性率有明显差异,但与现有文献相比,差异不具有统计学意义。这可能是由于乳腺外科医生的专业知识水平较高、导线标记精确或 IOUS 技术未标准化所致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ultraschall in Der Medizin
Ultraschall in Der Medizin 医学-核医学
CiteScore
5.30
自引率
8.80%
发文量
228
审稿时长
6-12 weeks
期刊介绍: Ultraschall in der Medizin / European Journal of Ultrasound publishes scientific papers and contributions from a variety of disciplines on the diagnostic and therapeutic applications of ultrasound with an emphasis on clinical application. Technical papers with a physiological theme as well as the interaction between ultrasound and biological systems might also occasionally be considered for peer review and publication, provided that the translational relevance is high and the link with clinical applications is tight. The editors and the publishers reserve the right to publish selected articles online only. Authors are welcome to submit supplementary video material. Letters and comments are also accepted, promoting a vivid exchange of opinions and scientific discussions.
期刊最新文献
The impact of real-time ultrasound guidance on ventricular catheter placement in cerebrospinal fluid shunts - a single-center study. The reliability and validity of superb microvascular imaging as a potential disease activity marker in rheumatoid arthritis. Fetal cardiovascular function in a late-onset SGA and FGR cohort: CURIOSA study. Risk-based ultrasound probe quality assurance - a single center proof-of-concept study. Evaluation of placenta and fetal lung using shear wave elastography in gestational diabetes mellitus: An innovative approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1