Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs.
Erik Kowalski, Alexandre R M Pelegrinelli, Nicholas Ryan, Geoffrey Dervin, Mario Lamontagne
{"title":"Muscle Activity and Biomechanics While Descending a Staircase After Total Knee Arthroplasty: A Study Comparing Different Posterior Stabilized and Medial Ball-and-Socket Designs.","authors":"Erik Kowalski, Alexandre R M Pelegrinelli, Nicholas Ryan, Geoffrey Dervin, Mario Lamontagne","doi":"10.1016/j.arth.2024.06.022","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Many patients report more difficulty when descending stairs compared to level walking after total knee arthroplasty (TKA). Different implant designs can affect knee biomechanics and muscle activity during gait, but their effect during stair descent is unclear. The purpose of this study was to evaluate knee biomechanics and muscle activations of quadriceps, hamstrings, and gastrocnemius muscles during a stair descent task in patients who underwent TKA with either a posterior stabilized (PS) or medial ball-and-socket (MBS) implant and to compare them to a group of healthy controls.</p><p><strong>Methods: </strong>There were 28 TKA patients who were randomized to either an MBS (n = 14) or PS (n = 14) implant and were compared with 14 controls. Patients visited the biomechanics lab approximately 12 months after TKA, where knee biomechanics and muscle activity were measured as they descended a 3-step staircase.</p><p><strong>Results: </strong>Compared to the MBS and control groups, the PS group descended the stairs with a reduced knee flexion angle and greater hamstring muscle activation throughout single limb support. Knee joint moments and power were similar between the MBS and PS groups, but neither reached the level of the control group.</p><p><strong>Conclusions: </strong>Lower knee flexion angles and increased hamstring muscle activity indicated that the PS group descended the stairs with a stiffer knee gait pattern than the MBS group. The MBS implant design may provide additional stability as patients require less muscle activity than the PS group.</p>","PeriodicalId":51077,"journal":{"name":"Journal of Arthroplasty","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arthroplasty","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.arth.2024.06.022","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/18 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Many patients report more difficulty when descending stairs compared to level walking after total knee arthroplasty (TKA). Different implant designs can affect knee biomechanics and muscle activity during gait, but their effect during stair descent is unclear. The purpose of this study was to evaluate knee biomechanics and muscle activations of quadriceps, hamstrings, and gastrocnemius muscles during a stair descent task in patients who underwent TKA with either a posterior stabilized (PS) or medial ball-and-socket (MBS) implant and to compare them to a group of healthy controls.
Methods: There were 28 TKA patients who were randomized to either an MBS (n = 14) or PS (n = 14) implant and were compared with 14 controls. Patients visited the biomechanics lab approximately 12 months after TKA, where knee biomechanics and muscle activity were measured as they descended a 3-step staircase.
Results: Compared to the MBS and control groups, the PS group descended the stairs with a reduced knee flexion angle and greater hamstring muscle activation throughout single limb support. Knee joint moments and power were similar between the MBS and PS groups, but neither reached the level of the control group.
Conclusions: Lower knee flexion angles and increased hamstring muscle activity indicated that the PS group descended the stairs with a stiffer knee gait pattern than the MBS group. The MBS implant design may provide additional stability as patients require less muscle activity than the PS group.
期刊介绍:
The Journal of Arthroplasty brings together the clinical and scientific foundations for joint replacement. This peer-reviewed journal publishes original research and manuscripts of the highest quality from all areas relating to joint replacement or the treatment of its complications, including those dealing with clinical series and experience, prosthetic design, biomechanics, biomaterials, metallurgy, biologic response to arthroplasty materials in vivo and in vitro.