Masao Watanabe, Stephan Leyser, Jens Theysohn, Benedikt Schaarschmidt, Johannes Ludwig, Wolfgang P Fendler, Alexandros Moraitis, Harald Lahner, Annie Mathew, Ken Herrmann, Manuel Weber
{"title":"Dose-Response Relationship in Patients with Liver Metastases from Neuroendocrine Neoplasms Undergoing Radioembolization with <sup>90</sup>Y Glass Microspheres.","authors":"Masao Watanabe, Stephan Leyser, Jens Theysohn, Benedikt Schaarschmidt, Johannes Ludwig, Wolfgang P Fendler, Alexandros Moraitis, Harald Lahner, Annie Mathew, Ken Herrmann, Manuel Weber","doi":"10.2967/jnumed.124.267774","DOIUrl":null,"url":null,"abstract":"<p><p>The benefit of multicompartment dosimetry in the radioembolization of neuroendocrine neoplasms is not firmly established. We retrospectively assessed its potential with patient outcome. <b>Methods:</b> Forty-three patients were eligible. The association of mean absorbed dose (MAD) for tumors and treatment response was tested per lesion with a receiver operating characteristic curve analysis, and the association of MAD with progression-free survival (PFS) and overall survival was tested per patient using uni- and multivariate Cox regression analyses. <b>Results:</b> The area under the curve for treatment response based on MAD was 0.79 (cutoff, 196.6 Gy; <i>P</i> < 0.0001). For global PFS, grade (grade 2 vs. 1: hazard ratio [HR], 2.51; <i>P</i> = 0.042; grade 3 vs. 1: HR, 62.44; <i>P</i> < 0.001), tumor origin (HR, 6.58; <i>P</i> < 0.001), and MAD (HR, 0.998; <i>P</i> = 0.003) were significant. For overall survival, no prognostic parameters were significant. <b>Conclusion:</b> In line with prior publications, a MAD of more than 200 Gy seemed to favor treatment response. MAD was also associated with PFS and may be of interest for radioembolization planning for neuroendocrine neoplasm patients.</p>","PeriodicalId":94099,"journal":{"name":"Journal of nuclear medicine : official publication, Society of Nuclear Medicine","volume":" ","pages":"1175-1180"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of nuclear medicine : official publication, Society of Nuclear Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2967/jnumed.124.267774","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The benefit of multicompartment dosimetry in the radioembolization of neuroendocrine neoplasms is not firmly established. We retrospectively assessed its potential with patient outcome. Methods: Forty-three patients were eligible. The association of mean absorbed dose (MAD) for tumors and treatment response was tested per lesion with a receiver operating characteristic curve analysis, and the association of MAD with progression-free survival (PFS) and overall survival was tested per patient using uni- and multivariate Cox regression analyses. Results: The area under the curve for treatment response based on MAD was 0.79 (cutoff, 196.6 Gy; P < 0.0001). For global PFS, grade (grade 2 vs. 1: hazard ratio [HR], 2.51; P = 0.042; grade 3 vs. 1: HR, 62.44; P < 0.001), tumor origin (HR, 6.58; P < 0.001), and MAD (HR, 0.998; P = 0.003) were significant. For overall survival, no prognostic parameters were significant. Conclusion: In line with prior publications, a MAD of more than 200 Gy seemed to favor treatment response. MAD was also associated with PFS and may be of interest for radioembolization planning for neuroendocrine neoplasm patients.