Assessment of the Predictive Ability of Theranostics for Corneal Cross-linking in Treating Keratoconus: A Randomized Clinical Trial.

IF 13.1 1区 医学 Q1 OPHTHALMOLOGY Ophthalmology Pub Date : 2024-12-01 Epub Date: 2024-06-20 DOI:10.1016/j.ophtha.2024.06.012
Anna Maria Roszkowska, Vincenzo Scorcia, Rita Mencucci, Giuseppe Giannaccare, Giuseppe Lombardo, Danilo Alunni Fegatelli, Annarita Vestri, Luca Bifezzi, Giuseppe Massimo Bernava, Sebastiano Serrao, Marco Lombardo
{"title":"Assessment of the Predictive Ability of Theranostics for Corneal Cross-linking in Treating Keratoconus: A Randomized Clinical Trial.","authors":"Anna Maria Roszkowska, Vincenzo Scorcia, Rita Mencucci, Giuseppe Giannaccare, Giuseppe Lombardo, Danilo Alunni Fegatelli, Annarita Vestri, Luca Bifezzi, Giuseppe Massimo Bernava, Sebastiano Serrao, Marco Lombardo","doi":"10.1016/j.ophtha.2024.06.012","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To validate the ability of theranostic imaging biomarkers in assessing corneal cross-linking (CXL) efficacy in flattening the maximum keratometry (K<sub>max</sub>) index.</p><p><strong>Design: </strong>Prospective, randomized, multicenter, masked clinical trial (ClinicalTrails.gov identifier, NCT05457647).</p><p><strong>Participants: </strong>Fifty patients with progressive keratoconus.</p><p><strong>Intervention: </strong>Participants were stratified to undergo epithelium-off (25 eyes) and epithelium-on (25 eyes) CXL protocols using an ultraviolet A (UV-A) medical device with theranostic software. The device controlled UV-A light both for performing CXL and assessing the corneal riboflavin concentration (riboflavin score) and treatment effect (theranostic score). A 0.22% riboflavin formulation was applied onto the cornea for 15 minutes and 20 minutes in epithelium-off and epithelium-on protocols, respectively. All eyes underwent 9 minutes of UV-A irradiance at 10 mW/cm<sup>2</sup>.</p><p><strong>Main outcome measures: </strong>The primary outcome measure was validation of the combined use of theranostic imaging biomarkers through measurement of their accuracy (proportion of correctly classified eyes) and precision (positive predictive value) to classify eyes correctly and predict a K<sub>max</sub> flattening at 1 year after CXL. Other outcome measures included change in K<sub>max</sub>, endothelial cell density, uncorrected and corrected distance visual acuity, manifest spherical equivalent refraction and central corneal thickness 1 year after CXL.</p><p><strong>Results: </strong>Accuracy and precision of the theranostic imaging biomarkers in predicting eyes that had >0.1 diopter (D) of K<sub>max</sub> flattening at 1 year were 91% and 95%, respectively. The K<sub>max</sub> value significantly flattened by a median of -1.3 D (IQR, -2.11 to -0.49 D; P < 0.001); both the uncorrected and corrected distance visual acuity improved by a median of -0.1 logarithm of the minimum angle of resolution (logMAR; IQR, -0.3 to 0.0 logMAR [P < 0.001] and -0.2 to 0.0 logMAR [P < 0.001], respectively). No significant changes in endothelial cell density (P = 0.33) or central corneal thickness (P = 0.07) were noted 1 year after surgery.</p><p><strong>Conclusions: </strong>The study demonstrated the efficacy of integrating theranostics in a UV-A medical device for the precise and predictive treatment of keratoconus with epithelium-off and epithelium-on CXL protocols. Concentration of riboflavin and its UV-A light mediated photoactivation in the cornea are the primary factors determining CXL efficacy.</p><p><strong>Financial disclosure(s): </strong>Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.</p>","PeriodicalId":19533,"journal":{"name":"Ophthalmology","volume":" ","pages":"1403-1415"},"PeriodicalIF":13.1000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.ophtha.2024.06.012","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/20 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To validate the ability of theranostic imaging biomarkers in assessing corneal cross-linking (CXL) efficacy in flattening the maximum keratometry (Kmax) index.

Design: Prospective, randomized, multicenter, masked clinical trial (ClinicalTrails.gov identifier, NCT05457647).

Participants: Fifty patients with progressive keratoconus.

Intervention: Participants were stratified to undergo epithelium-off (25 eyes) and epithelium-on (25 eyes) CXL protocols using an ultraviolet A (UV-A) medical device with theranostic software. The device controlled UV-A light both for performing CXL and assessing the corneal riboflavin concentration (riboflavin score) and treatment effect (theranostic score). A 0.22% riboflavin formulation was applied onto the cornea for 15 minutes and 20 minutes in epithelium-off and epithelium-on protocols, respectively. All eyes underwent 9 minutes of UV-A irradiance at 10 mW/cm2.

Main outcome measures: The primary outcome measure was validation of the combined use of theranostic imaging biomarkers through measurement of their accuracy (proportion of correctly classified eyes) and precision (positive predictive value) to classify eyes correctly and predict a Kmax flattening at 1 year after CXL. Other outcome measures included change in Kmax, endothelial cell density, uncorrected and corrected distance visual acuity, manifest spherical equivalent refraction and central corneal thickness 1 year after CXL.

Results: Accuracy and precision of the theranostic imaging biomarkers in predicting eyes that had >0.1 diopter (D) of Kmax flattening at 1 year were 91% and 95%, respectively. The Kmax value significantly flattened by a median of -1.3 D (IQR, -2.11 to -0.49 D; P < 0.001); both the uncorrected and corrected distance visual acuity improved by a median of -0.1 logarithm of the minimum angle of resolution (logMAR; IQR, -0.3 to 0.0 logMAR [P < 0.001] and -0.2 to 0.0 logMAR [P < 0.001], respectively). No significant changes in endothelial cell density (P = 0.33) or central corneal thickness (P = 0.07) were noted 1 year after surgery.

Conclusions: The study demonstrated the efficacy of integrating theranostics in a UV-A medical device for the precise and predictive treatment of keratoconus with epithelium-off and epithelium-on CXL protocols. Concentration of riboflavin and its UV-A light mediated photoactivation in the cornea are the primary factors determining CXL efficacy.

Financial disclosure(s): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
角膜交联疗法治疗角膜炎的疗效预测能力评估:随机临床试验。
目的:验证治疗成像生物标志物在评估角膜交联术(CXL)平滑最大角膜指数(Kmax)方面的能力:前瞻性、随机、多中心、掩蔽临床试验(NCT05457647):干预:对参与者进行分层,分别采用上皮-关闭(epi-off;25 眼)和上皮-开启(epi-on;25 眼)CXL 方案,使用包含治疗软件模块的 UV-A 医疗设备。该设备使用受控紫外线-A 光进行 CXL,并实时估算角膜核黄素浓度(核黄素评分)和评估治疗效果(治疗评分)。在外延-关闭和外延-开启方案中,将 0.22% 核黄素制剂分别涂在角膜上 15 分钟和 20 分钟。所有眼睛均接受 9 分钟 10 mW/cm2 的紫外线-A 照射:主要结果指标是通过测量治疗成像生物标志物的准确性(正确分类眼睛的比例)和精确性(阳性预测值)来验证治疗成像生物标志物的综合使用,以正确分类眼睛并积极预测 CXL 后 1 年的 Kmax 平整度。其他结果测量指标包括 CXL 一年后 Kmax、内皮细胞密度、未矫正和矫正远视力、显性球面等效屈光度和中央角膜厚度的变化:结果:联合使用治疗成像生物标志物预测 1 年后 Kmax 值变平超过 0.1 屈光度 (D) 的眼睛的准确率和精确率分别为 91% 和 95%。Kmax值明显变平,中位数为-1.3 D(IQR:-2.11, -0.49 D;P <0.001);未矫正和矫正远视力均提高,中位数为-0.1 LogMAR(IQR:-0.3, 0.0 LogMAR;P <0.001,IQR:-0.2, 0.0 LogMAR;P <0.001)。术后一年,内皮细胞密度(P = 0.33)和角膜中央厚度(P = 0.07)无明显变化:该研究证明了将治疗技术整合到 UV-A 医疗设备中,通过外延-关闭和外延-开启 CXL 方案对角膜病进行精确和预测性治疗的有效性。角膜中核黄素的浓度及其紫外线-A 光介导的光激活作用是决定 CXL 治疗效果的主要因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ophthalmology
Ophthalmology 医学-眼科学
CiteScore
22.30
自引率
3.60%
发文量
412
审稿时长
18 days
期刊介绍: The journal Ophthalmology, from the American Academy of Ophthalmology, contributes to society by publishing research in clinical and basic science related to vision.It upholds excellence through unbiased peer-review, fostering innovation, promoting discovery, and encouraging lifelong learning.
期刊最新文献
Corrigendum. Special Commentary: Cerebral/Cortical Visual Impairment Working Definition: A Report from the National Institutes of Health CVI Workshop. What Is Cerebral/Cortical Visual Impairment and Why Do We Need a New Definition? Cavernous Hemangioma of the Retina and Brain. A Child with Posterior Ectopic Cilia.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1